Move the libusb_detach_kernel_driver() call after the code that
sets the usb->devhdl pointer, otherwise it'll be NULL and result
in a segfault.
#0 libusb_kernel_driver_active (dev=0x0, interface_number=0) at libusb/core.c:1711
#1 dev_open (sdi=0x12d99f0) at src/hardware/fx2lafw/api.c:374
[...]
Tested on a device with the default Cypress VID/PID and one with
the Saleae Logic VID/PID, both works fine.
The timerfd descriptor is closed automatically by
g_io_channel_shutdown(). No need to close it manually.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
At high sampling rates and maximum channels we are not able to acquire
samples fast enough, even though frontends still think that samples
arrive on time. This causes visible shifts in frontend plots.
To compensate for the delay introduce the following workaround: check
if we are late (if any clock events have been missed) and resend the
last frame n times (n == number of missed clock events).
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Currently baylibre-acme uses a fake pipe as the input channel required by
libsigrok API and calls sleep() in the data acquisition callback to create
intervals between measurements.
Switch to a more elegant approach: use Linux' timerfd and set a periodic
timer equal to the sampling rate. Then read the data every time the timer
expires.
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Opening a file has a cost (security, allocation, syscalls). The
read_sample() function always does an open/read/close sequence.
In order to optimize that, let's open the file at the moment the
acquisition starts, close it when the acquisition stops and make
read_sample() only lseek() to the beginning of the file and read
the value.
Signed-off-by: Daniel Lezcano <daniel.lezcano@free.fr>
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
This was originally done as an optimization in combination with a list
reversal which has since been removed from the code. Thus, un-reverse
the channels so that the UI lists them in the correct order again.
The Chroma 62000P series comes in various models with different
current and voltage capabilities. These are encoded in the *IDN
string, so just get them from there, rather than needing a profile
for every model.
All those options are currently applied only to power-supplies
but they could apply as well to electronic loads, except for the
fact that electronic loads channels are called inputs and not
outputs.
Also when you think about an SMU (or any kind of 4-quadrants
power-supply), their channels can both source and sink current,
so they can be considered as input as much as output.
Those SR_CONF_* are thus renamed so that they can be used in all
those situations.
For devices such as the HP 6632B the following invocation was failing due to
scpi_cmd(sdi, SCPI_CMD_SELECT_CHANNEL, ...) returning SR_OK_CONTINUE.
./sigrok-cli -d scpi-pps:conn=/dev/ttyUSB0:serialcomm=9600/8n1 --continuous
sr: session: sr_session_start: could not start an acquisition (not enough data to decide error status yet)
Failed to start session.
This patch only adds the needed infrastructure to control output
frequency in the same manner as output voltage or current limit. This
does require a new field in the channel_spec struct, for the sake of
symmetry.
Only the capabilities which map directly to SCPI commands supported by
sigrok are implemented at this time. This is sufficient to control
the most often used functionality of this AC source
Check the return value of sr_gpio_setval_export() in bl_acme_set_power_off()
and return an appropriate error if the call fails.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
This reverts commit 4cd97e5ad7.
We should actually check the return value of sr_gpio_setval_export().
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Add LIBUSB_CALL where needed to avoid warnings such as the following:
In file included from src/hardware/hantek-dso/api.c:34:0:
src/hardware/hantek-dso/dso.h:212:13:
note: expected 'libusb_transfer_cb_fn' but argument is of type 'void (*)(struct libusb_transfer *)'
SR_PRIV int dso_get_channeldata(const struct sr_dev_inst *sdi,
^
CC src/hardware/baylibre-acme/protocol.lo
../src/hardware/baylibre-acme/protocol.c: In function 'bl_acme_set_power_off':
../src/hardware/baylibre-acme/protocol.c:417:6: warning: variable 'val' set but not used [-Wunused-but-set-variable]
int val;
^
Both ina2xx and tmp401 linux drivers used by baylibre-acme expose
the standard hwmon update_interval attribute, which affects the internal
update interval of the chip.
When setting samplerate for data acquisition try to modify this
attribute accordingly.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
PROBE_FACTOR and POWER_OFF options are advertised for all ACME probes
(channel groups) regardless of whether they actually have given capability.
Check these options in config_list() at runtime and only advertise them
for probes which support them.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Tested on an MSO1104Z with firmware 00.04.02.SP4.
The analog channels are captured correctly. For the MSO series, with digital
channels, there are two outstanding issues:
1. Logic data is retrieved per-channel, one byte per sample, with the value
in the LSB of each byte. The current datafeed logic format doesn't allow
this format to be passed on directly. I suggest we resolve that rather than
making the driver buffer and interleave the data.
As stands, the code will retrieve data for all channels and pass it onto
the datafeed with unitsize=1. Channel D0 can used correctly if selected
alone. For other channels, data is passed to the frontend but the API does
not provide a way to associate it with the correct channel.
2. Channels CH3 and CH4 are multiplexed with D0-7 and D8-15 respectively, so
enabling these is mutually exclusive. We don't currently have a way to
express this constraint to the frontend.
This patchset was originally done by eightdot <gituser@eightdot.eu> by
manually forward-porting parts of the changes done by Bert Vermeulen (see
previous commits), but then heavily modified by Uwe Hermann to be based on
top off the (git-)rebased patches from Bert Vermeulen instead.
Note: This initial DSLogic code is *not* yet in a working or usable
state. It should be considered as a basis for further work only, for now.
CC src/hardware/openbench-logic-sniffer/api.lo
../src/hardware/openbench-logic-sniffer/api.c: In function 'scan':
../src/hardware/openbench-logic-sniffer/api.c:103:10: warning: unused
variable 'probefd' [-Wunused-variable]
GPollFD probefd;
^
Use the more portable sp_input_waiting() instead of g_poll() with FDs.
Thanks to Martin Ling for the hints. This is tested on Linux and Win7
using an OLS; scanning for the device and starting an acquisition works.
Also, add some more debug output.
This fixes bug #562.
Split device options into general and channel group settings, and
adjust config_list() callback appropriately.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
There's indeed no g_fclose() unfortunately. The g_*() wrappers for file
handling are mainly there to deal with portability issues in file names
(encoding, character sets, etc) on different platforms.
Use PRIu64 to avoid the following compiler warning:
CC src/hardware/baylibre-acme/gpio.lo
protocol.c: In function 'bl_acme_set_shunt':
protocol.c:341:2: warning: format '%llu' expects argument of type 'long long unsigned int', but argument 3 has type 'uint64_t' [-Wformat=]
g_fprintf(fd, "%llu\n", MOHM_TO_UOHM(shunt));
^
Implement support for SR_CONF_PROBE_FACTOR setting in BayLibre ACME
driver. Given the channel-group parameter this allows to set the
shunt resistance for each probe.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Implement basic functionalities for baylibre-acme. Add support
for common config options, device detection and sample reading.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
We try to find the smallest diff by comparing each diff with
the previously known smallest diff, so initially, this smallest diff
should be INFINITY so that we are sure to find a smaller one.
This fixes the following exception:
sr: rigol-ds: Negative vdiv index: -1.
Caught exception: not applicable
These are available on e.g. Rigol DS1102E (or "upgraded" DS1052E).
Without this, if one of the channels happens to have been set to
one of the missing vdiv settings frontends (e.g. PulseView) will
have some trouble using the scope:
sr: hwdriver: sr_config_get(): key 30012 (vdiv) sdi 0x11bcb70 cg CH1
sr: rigol-ds: Negative vdiv index: -1.
std::exception
(lwla_convert_trigger): Fix trigger mask computation bug introduced
by recent change: Widen constant to 64 bit before shifting so that
channel nunmbers beyond 32 are processed correctly.
Use g_malloc0() for small allocations and assume they always
succeed. Simplify error handling in a few places accordingly.
Don't always sanity-check parameters for non-public (SR_PRIV)
functions, we require the developers to invoke them correctly.
This allows further error handling simplifications.
It fills the fields with reasonable default values that should suit
most of the drivers. Drivers are obviously free to override the fields
they want after initializing.
If the number and specs of the device's channels are not static, i.e.
need to be probed, this facility is needed.
Initially this will be used for the Philips PM2800 series, where only
the model returned by *IDN? is needed. However this could also be used
to do actual discovery with vendor-specific SCPI commands.
At least the Rigol DP800 series trigger the beeper when changing
channels remotely. Which gets rather annoying when doing acquisition
on three channels as fast as you can.