Frank Stettner 883db4dad1 hp-3478a: Fix glib variant ref count in SET MQ request. 2020-05-26 21:17:32 +02:00
Frank Stettner 1c8110dbc7 scpi-dmm: Fix coding style. 2020-05-26 21:17:25 +02:00
Tobias Faeth 6d2e307016 serial-dmm: Added support for Metex ME-21 multimeters 2020-05-26 21:11:48 +02:00
Sergey Rzhevsky 9785891436 ftdi-la: Add FT4232H PID:VID. 2020-05-02 17:01:39 +02:00
Richard 77f3c5e51f rigol-ds: Added support for the DS1202Z-E 2020-05-02 17:01:39 +02:00
Gerhard Sittig 8c381a353c hameg-hmo: use common helper to setup description of an analog value
Replace an open coded sequence of assignments to an aggregate of several
related structures. Prefer the common sr_analog_init() routine instead.
2020-05-02 17:01:39 +02:00
Gerhard Sittig 00f3c94386 uni-t-ut32x: drop redundant close and free at end of scan
The UT32x driver requires a user spec for the connection. The device
cannot get identified, that's why successful open/close for the port
will suffice. Lack of an input spec as well as failure in the early
scan phase will terminate the scan routine early.

When we reach the end of the scan which creates the device instance
and registers it with the list of found devices, the port already
is closed and the list of devices will never be empty. Remove the
redundant close call and the dead branch which frees the serial port.
2020-05-02 17:01:39 +02:00
Gerhard Sittig ff5fb18526 scpi-dmm: fix glib variant ref count in SET MQ request 2020-05-02 17:01:39 +02:00
Uwe Hermann 4c5ac0cf5b siglent-sds: Fix various compiler warnings.
src/hardware/siglent-sds/protocol.c: In function 'siglent_sds_get_digital':
  src/hardware/siglent-sds/protocol.c:382:35: warning: comparison between signed and unsigned integer expressions [-Wsign-compare]
          if (data_low_channels->len <= samples_index) {
                                     ^
  src/hardware/siglent-sds/protocol.c:391:36: warning: comparison between signed and unsigned integer expressions [-Wsign-compare]
          if (data_high_channels->len <= samples_index) {
                                      ^
  src/hardware/siglent-sds/protocol.c:417:32: warning: comparison between signed and unsigned integer expressions [-Wsign-compare]
       for (long index = 0; index < tmp_samplebuf->len; index++) {
                                  ^
  In file included from src/hardware/siglent-sds/protocol.c:37:0:
  src/hardware/siglent-sds/protocol.c: In function 'siglent_sds_receive':
  src/hardware/siglent-sds/protocol.h:28:20: warning: format '%li' expects argument of type 'long int', but argument 3 has type 'uint64_t {aka long long unsigned int}' [-Wformat=]
   #define LOG_PREFIX "siglent-sds"
                      ^
  ./src/libsigrok-internal.h:815:41: note: in expansion of macro 'LOG_PREFIX'
   #define sr_dbg(...) sr_log(SR_LOG_DBG,  LOG_PREFIX ": " __VA_ARGS__)
                                           ^
  src/hardware/siglent-sds/protocol.c:564:6: note: in expansion of macro 'sr_dbg'
        sr_dbg("Requesting: %li bytes.", devc->num_samples - devc->num_block_bytes);
        ^
  src/hardware/siglent-sds/protocol.c: In function 'siglent_sds_get_dev_cfg_horizontal':
  src/hardware/siglent-sds/protocol.h:28:20: warning: format '%lu' expects argument of type 'long unsigned int', but argument 3 has type 'uint64_t {aka long long unsigned int}' [-Wformat=]
   #define LOG_PREFIX "siglent-sds"
                      ^
  ./src/libsigrok-internal.h:815:41: note: in expansion of macro 'LOG_PREFIX'
   #define sr_dbg(...) sr_log(SR_LOG_DBG,  LOG_PREFIX ": " __VA_ARGS__)
                                           ^
  src/hardware/siglent-sds/protocol.c:933:2: note: in expansion of macro 'sr_dbg'
    sr_dbg("Current memory depth: %lu.", devc->memory_depth_analog);
    ^
2020-05-02 15:48:26 +02:00
Florian Schmidt 8f3c77db26 scpi-pps: fixed out-of-bounds array access...
when accessing devc->device->channels in config_list().
this array has to be accessed via the "hw_output_idx"

This fixes bug #1533.
2020-04-11 15:52:13 +02:00
Uwe Hermann f0aec55605 center-3xx: Fix incorrect values due to endianness issue.
Replace RL16S with RB16S, the values are big-endian.

This is related to the recently-fixed bug #1463.
2020-04-09 23:51:16 +02:00
Uwe Hermann 4c5f70063a Use std_session_send_df_frame_begin()/_end() where possible. 2020-04-08 23:54:25 +02:00
Uwe Hermann 7f7702b81b std: Rename std_session_send_frame_begin/_end(). 2020-04-08 23:35:44 +02:00
Uwe Hermann 0fa71943e3 Use std_session_send_df_trigger() where possible. 2020-04-08 23:21:39 +02:00
Uwe Hermann 148cf8bea1 zeroplus-logic-cube: Fix an issue when changing triggers.
Changing triggers (e.g. from low to high) would sometimes cause the
acquisition to seemingly "hang" due to missing variable initializations
(in reality the device would wait for incorrect triggers and/or on
incorrect channels).

This fixes bug #1535.
2020-04-08 22:58:02 +02:00
Jan Metzger 88daa0536c zeroplus-logic-cube: Enable edge-triggering capabilities.
This fixes bug #1334.
2020-04-08 22:57:02 +02:00
Christian Fruth c8dcd3ab72 korad-kaxxxxp: Add support for RND KA3005P V5.5 power supply 2020-04-07 00:54:18 +02:00
Peter van der Perk 082ca8d8bc korad-kaxxxxp: Add support for TENMA 72-2540 V5.2 power supply 2020-04-07 00:54:18 +02:00
Tom Matthews 3ff6cfeebe ftdi-la: add TUMPA VID:PID and JTAG pin names 2020-04-07 00:54:18 +02:00
v1ne 69c5d959e7 rdtech-dps: Make it work in SmuView
Without the mutex, concurrent reception from the ModBus port leads to CRC
errors.
2020-04-04 23:25:25 +02:00
Gerhard Sittig 56a1bf7b4b center-3xx: use common signed LE16 conversion for temperature value
Prefer the common conversion helper for little endian 16bit signed data.
The previous local implementation only worked for positive values, and
yielded incorrect results for negative temperatures.

This fixes bug #1463.
2020-04-04 23:25:25 +02:00
Elen Eisendle ca7d442692 serial-dmm/uni-t-dmm: Add UNI-T UT804 DMM definitions 2020-04-04 23:25:09 +02:00
Andreas Sandberg 5ff772410b gwinstek-gpd: Fix use of uninitialized variable
Signed-off-by: Andreas Sandberg <andreas@sandberg.pp.se>
2020-04-04 22:24:26 +02:00
Uwe Hermann 20680f58ff manson-hcs-3xxx: Support device IDs with and without "HCS-" prefix.
Since we've now seen lots of devices in the wild that come with the
"HCS-" prefix in the ID, it's probably safe to assume all of them
could have it.

This fixes bug #1530.
2020-03-24 21:10:27 +01:00
Uwe Hermann bfa79fbdb6 asix-sigma: Drop duplicate error message prefixes.
The sr_err() call automatically adds a prefix to all messages, in
this specific case "asix-sigma: " will be added.
2020-03-24 19:22:11 +01:00
Daniel Trnka 440810958c asix-sigma: move DRAM line buffer allocation closer to its use
Move the allocation of the DRAM line buffer in the sample download code
path closer to the location where that buffer is used and gets released.
2020-03-24 19:20:40 +01:00
Daniel Trnka f73b00b647 asix-sigma: check for successful register access in sample download
The previous implementation got stuck in an infinite loop when data
acquisition started, but the device got disconnected before the data
acquisition terminates. An implementation detail ignored communication
errors, and never saw the expected condition that was required to
continue in the sample download sequence. Unbreak that code path.
2020-03-24 19:20:40 +01:00
Uwe Hermann f5c863e572 korad-kaxxxxp: Fix max. possible current for all devices.
Even though the devices/websites/manuals usually say 0..30V, the
hardware actually accepts up to 31V, both via serial as well as by
simply rotating the knob on the device (and our driver already
reflects that).

The same is true for current, it's usually 0..5A as per docs, but many
(probably all) devices accept 5.1A via serial and knob.

Thus, set the max current of all devices to 5.1A (or 3.1A for 3A
devices). We're assuming they all have this property, and we've seen
this in practice on at least three different versions of the device.
2020-03-22 16:58:54 +01:00
David Sastre Medina 7415217ede korad-kaxxxxp: Add a new ID for KORAD KA3005P V4.2 power supply
On a recently acquired Korad KA3005P power supply, the ID supplied by the
device is not known by libsigrok.

$ sigrok-cli --driver=korad-kaxxxxp:conn=/dev/ttyACM0 --scan
sr: korad-kaxxxxp: Unknown model ID 'KORAD KA3005P V4.2' detected, aborting.

This fixes bug #1522.

Thanks to bitaround@gmail.com for the amperage fix.
2020-03-22 15:52:16 +01:00
jirjirjir c4a46475a6 rigol-ds: Rigol DS1152E-EDU support fix 2020-03-16 23:44:25 +01:00
Uwe Hermann f0362f595a agilent-dmm: Add Agilent U1237AX (completely untested). 2019-12-27 22:08:41 +01:00
Uwe Hermann e47e23355f agilent-dmm: U127x: Fix mode switch event handling.
The DMMs report as an event to which mode the user switched (by turning the
rotary switch): "*0", "*1", etc.

Most other DMMs have few modes, but the U127x DMMs have up to 11 different
modes (i.e., "*10" is a valid event).
2019-12-27 20:59:04 +01:00
Uwe Hermann d649ff2290 manson-hcs-3xxx: support new HCS-3200 / PPS-13610 model string.
This fixes bug #1441.
2019-12-22 23:19:47 +01:00
Uwe Hermann c810ad60b4 mastech-ms6514: Add missing string.h #include. 2019-12-22 21:06:46 +01:00
Dave Buechi 23669c3df3 Initial support for MASTECH MS6514 thermometer 2019-12-22 15:32:51 +01:00
Frank Stettner 675cb86f15 hp-3478a: Check for overflow. 2019-12-20 23:08:51 +01:00
Frank Stettner 7812a5c802 hp-3478a: Add get/set/list of digits. 2019-12-20 23:08:51 +01:00
Frank Stettner e5137b9343 hp-3478a: Add get/set/list of measurement ranges. 2019-12-20 23:07:25 +01:00
Michał Janiszewski e3f86ef5fc beaglelogic: Fix mismatched printf specifiers. 2019-12-19 22:20:47 +01:00
Gerhard Sittig dc40081706 asix-sigma: comment on trigger/stop position, silence warning
Add a comment on the logic which skips the upper 64 bytes of a 512 bytes
chunk in the Asix Sigma's sample memory. Move the initial assignment and
the subsequent update from a value which was retrieved from a hardware
register closer together for awareness during maintenance. Pre-setting a
high position value that will never match when the feature is not in use
is very appropriate.

Adjust the sigma_read_pos() routine to handle triggerpos identically to
stoppos. The test condition's intention is to check whether a decrement
of the position ends up in the meta data section of a chunk. The previous
implementation tested whether a pointer to the position variable ended in
0x1ff when decremented -- which is unrelated to the driver's operation.
It's assumed that no harm was done because the trigger feature is
unsupported (see bug #359).

This silences the compiler warning reported in bug #1411.
2019-12-19 21:18:35 +01:00
Adrian Godwin a16198316f scpi-dmm: Added minimal support for HP34401A (PR #36) 2019-12-17 00:08:09 +01:00
Peter Åstrand cf6beeb20d korad-kaxxxxp: Add support for RND 320-KD3005P (PR #35)
Since this model replies with a serial number, truncate before that
2019-12-17 00:08:03 +01:00
Sylvain Pelissier 24931412ee lecroy-xstream: Remove header read (PR #33) 2019-12-16 23:52:50 +01:00
Andreas Sandberg 19ab8e363e fluke-dmm: Fix use-after-free bugs
The handler for fluke 18x and 28x DMMs allocates several data
structures on the stack that are used after they have been freed when
creating a data feed packet.

Restructure the code so that all handlers send their own packets. As a
bonus, this avoid a couple of small heap allocations.
2019-12-16 15:51:07 +01:00
Frank Stettner 253d653d4d korad-kaxxxxp: Reword debug output for the status byte. 2019-12-16 15:42:53 +01:00
Frank Stettner 2e129b8b25 korad-kaxxxxp: Send META packet when states have changed. 2019-12-16 15:42:49 +01:00
Frank Stettner 8da30037cf korad-kaxxxxp: Fix bug when setting values while acquisition is running.
By separating the variables that holds the get and set values, the output
state, OVP and OCP can now be set while the acquisition is running.
Also some variables are named more clearly.
2019-12-16 15:42:36 +01:00
Frank Stettner dfdf4c83ff rdtech-dps: Send META package when states have changed. 2019-12-16 15:38:58 +01:00
Frank Stettner cce6a8a1b7 rdtech-dps: Handle different current/voltage digits for the various models. 2019-12-16 15:38:54 +01:00
Frank Stettner aff2094193 rdtech-dps: Retry sr_modbus_read_holding_registers() up to 3 times.
The communication with the rdtech power supplies is not very reliable,
especially during the start. Because of that, the driver tries to read the
modbus registers up to three times.
Nevertheless there is the chance, that the communication fails.
2019-11-13 10:09:07 +01:00
Frank Stettner c9b187a607 rdtech-dps: Use SR_MQFLAG_DC only for voltage and current channels. 2019-11-12 23:14:33 +01:00
Frank Stettner 7c0891b0b8 rdtech-dps: Synchronize read and write operations. 2019-11-12 23:14:33 +01:00
Gerhard Sittig ad4174c1d8 ols: introduce metadata quirks support, unbreak Logic Shrimp
Introduce quirks support for devices which provide incomplete metadata.
Add conservative logic to unbreak the Logic Shrimp. Amend previously
received information when it was incomplete, but don't interfere if a
future firmware version fixes the issue.

Without this change, the device gets detected but "has zero channels"
and would be unusable. Because when a device provides metadata, these
details are used exclusively, no fallbacks apply.
2019-11-07 23:16:06 +01:00
Marc Schink f216309fd0 demo: Fix memory leak
How to reproduce:

 $ G_SLICE=always-malloc G_DEBUG=gc-friendly valgrind --leak-check=full sigrok-cli --scan --driver demo

Signed-off-by: Marc Schink <dev@zapb.de>
2019-11-02 15:32:22 +01:00
Gerhard Sittig 76dea519e4 mooshimeter-dmm: silence compiler warning (memset() prototypes)
The Mooshimeter driver uses mem*() and str*() library calls. Include the
<string.h> header file to silence compiler warnings.

  ...
  ./src/hardware/mooshimeter-dmm/protocol.c: In function 'lookup_tree_path':
  ./src/hardware/mooshimeter-dmm/protocol.c:275:3: warning: implicit declaration of function 'strchr' [-Wimplicit-function-declaration]
     end = strchr(path, ':');
     ^
  ./src/hardware/mooshimeter-dmm/protocol.c:275:9: warning: incompatible implicit declaration of built-in function 'strchr' [enabled by default]
     end = strchr(path, ':');
           ^
  ...
2019-10-29 17:50:07 +01:00
Uwe Hermann 59d916fe67 mooshimeter-dmm: Only report successful scan upon working connection. 2019-10-26 21:10:48 +02:00
Derek Hageman ebcd1aba01 Add support for the Mooshimeter DMM
This adds support for the Mooshim Engineering BLE based Mooshimeter.
Because the meter requires raw BLE packets, the driver uses the BLE
layer directly. Since the meter has no physical way of configuring it,
the actual configuration is set entirely with sigrok device options.
2019-10-22 12:21:47 +02:00
Kate J. Temkin 1656cd4a4a fx2lafw: allow for sampling at 48MHz, matching a fw change 2019-10-01 23:52:00 +02:00
Jan Luebbe 6d8205ad9a manson-hcs-3xxx: support new firmware for HCS-3202
A recently bought device seems to use a different model string, but
still speaks the same protocol.
2019-09-27 15:35:38 +02:00
Sebastian Reichel f6129c8f0c rigol-ds: Add initial Rigol MSO5000 support.
This adds basic support for the Rigol MSO5000 series. It has
the same problems as the DS4000 series: Live capture provides
one digital channel per byte. Buffered memory returns the data
compressed (one byte has 8 digital channels), but the banks are
read separately. It's not possible to read uint16.
2019-08-21 14:54:12 +02:00
Miklos Marton 4d8338bb96 demo: Add random analog signal generation 2019-07-31 23:15:18 +02:00
Elen Eisendle b1b8a7d079 korad-kaxxxxp: Add Korad KD6005P 2019-07-31 23:15:11 +02:00
Gerhard Sittig b50970a541 lcr/vc4080: introduce LCR packet parser for Voltcraft 4080 (and PeakTech 2165)
Introduce the lcr/vc4080.c source file which implements the parser for
the serial data stream of the Voltcraft 4080 LCR meter. Add the meter to
the list of supported devices in the serial-lcr driver, as well as the
PeakTech 2165 LCR meter which is another compatible device.

This implementation contains a workaround for USB based serial cables
which seem to suffer from incomplete parity handling (observed with the
FT232R based PeakTech cable). Similar approaches were seen in existing
DMM drivers.

This implementation supports the main and secondary displays. The D and Q
"displays" which are communicated in the serial packets appear unreliable
and redundant, users can have the D and Q values shown in the supported
displays.
2019-07-31 22:40:44 +02:00
Gerhard Sittig 66c300c4a6 serial-lcr: also request packets before initial state retrieval
Commit cb5cd1538f introduced packet request support in the serial-lcr
device driver. Calls were added to the detection of the device's
presence, and the periodic acquisition of measurement data. Add another
call to the device configuration retrieval that follows the presence
detection, without it communication timed out with no data received.

Also slightly raise the timeout for this device configuration gathering
phase. With one second sharp, the VC4080 was detected, but getting its
current configuration kept failing. This device's serial communication
is extra slow (1200 bps) and the packets are rather large (39 bytes).
Which made the stream detect's receive routine stop checking for the
availability of more data while a packet was being received.
2019-07-31 15:23:03 +02:00
Gerhard Sittig c4d2e6fa5e serial-lcr: move probe, dev inst creation, data read out of scan
Move the initial device probe (LCR packet validity check), the creation
of the device instance after successful probe, and the subsequent packet
inspection after resource allocation out of the scan routine. This shall
improve readability of the serial-lcr driver's probe logic, and reduces
diffs when handling of multiple connections gets added later.

Add a developer comment, the serial-lcr driver needs to handle multiple
connections when the conn= spec is ambiguous (multiple cables of the
same type, with the same VID:PID).
2019-07-31 15:23:03 +02:00
Uwe Hermann 1838d9f13f hameg-hmo: Fix two compiler warnings (-Wstringop-truncation).
src/hardware/hameg-hmo/protocol.c: In function ‘hmo_scope_state_get’:
  src/hardware/hameg-hmo/protocol.c:1130:2: warning: ‘strncpy’ specified bound 20 equals destination size [-Wstringop-truncation]
    strncpy(state->trigger_pattern,
    ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
     sr_scpi_unquote_string(tmp_str),
     ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
     MAX_ANALOG_CHANNEL_COUNT + MAX_DIGITAL_CHANNEL_COUNT);
     ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    CC       src/hardware/hp-3478a/api.lo
    CC       src/hardware/hung-chang-dso-2100/protocol.lo
  src/hardware/hameg-hmo/api.c: In function ‘config_set’:
  src/hardware/hameg-hmo/api.c:388:3: warning: ‘strncpy’ specified bound 20 equals destination size [-Wstringop-truncation]
     strncpy(state->trigger_pattern,
     ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
      tmp_str,
      ~~~~~~~~
      MAX_ANALOG_CHANNEL_COUNT + MAX_DIGITAL_CHANNEL_COUNT);
      ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
2019-07-30 23:53:42 +02:00
Uwe Hermann c38d69adf4 hameg-hmo: Fix two compiler warnings (-Warray-bounds).
src/hardware/hameg-hmo/protocol.c: In function ‘hmo_scope_state_get’:
  src/hardware/hameg-hmo/protocol.c:1035:31: warning: array subscript 0 is above array bounds of ‘char *[0]’ [-Warray-bounds]
     g_free(logic_threshold_short[i]);
            ~~~~~~~~~~~~~~~~~~~~~^~~
  src/hardware/hameg-hmo/protocol.c:1035:31: warning: array subscript 0 is above array bounds of ‘char *[0]’ [-Warray-bounds]
  src/hardware/hameg-hmo/protocol.c:974:24: warning: array subscript 0 is above array bounds of ‘char *[0]’ [-Warray-bounds]
     logic_threshold_short[i] = g_strdup((*config->logic_threshold)[i]);
     ~~~~~~~~~~~~~~~~~~~~~^~~
  src/hardware/hameg-hmo/protocol.c:974:24: warning: array subscript 0 is above array bounds of ‘char *[0]’ [-Warray-bounds]
2019-07-30 23:53:42 +02:00
Guido Trentalancia 97a000748a hameg-hmo: Add SR_CONF_HIGH_RESOLUTION and SR_CONF_PEAK_DETECTION.
Implement High Resolution mode and Peak Detection settings.

Beautify the code by reordering the Trigger Source settings
definitions.
2019-07-26 01:43:19 +02:00
Guido Trentalancia 29a9b1a0bd hameg-hmo: Get SCPI_CMD_GET_HORIZONTAL_DIV at runtime.
Get the number of horizontal divisions from the device (at runtime)
instead of hardcoding its value in the driver.
2019-07-26 01:43:19 +02:00
Guido Trentalancia a12456f1bb hameg-hmo: Don't hardcode POD/channel numbers.
Don't hardcode the number of PODs or the number of logic (digital)
channels per POD.
2019-07-26 00:55:40 +02:00
Guido Trentalancia 0c96de7223 hameg-hmo: Remove duplicate function call.
This call was inadvertently left around in commit
8cccbac8da.
2019-07-26 00:55:40 +02:00
Guido Trentalancia 66ddc22a1d hameg-hmo: Rename SCPI_CMD_GET_VERTICAL_DIV to *_SCALE.
Fix the name of the SCPI command used to get the vertical scale.
2019-07-26 00:55:40 +02:00
Guido Trentalancia 396af5ad7d hameg-hmo: Beautify trigger pattern.
Beautify the trigger pattern by removing the quotes from the SCPI response
using sr_scpi_unquote_string() and improve the string pattern handling.
2019-07-26 00:55:40 +02:00
Guido Trentalancia a058de0410 hameg-hmo: Add missing 1ns timebase for some models.
Extend the timebase setting down to 1ns from the current limit
of 2ns for all supported series except the HMO Compact.
2019-07-26 00:55:40 +02:00
Guido Trentalancia 0184aca19d hameg-hmo: Add missing quotes for SCPI_CMD_SET_TRIGGER_PATTERN. 2019-07-26 00:11:07 +02:00
Guido Trentalancia b720f16eb5 hameg-hmo: Add RTA4000 MSO support (untested).
According to the latest available version of the manual, as
for the RTB2000 and RTM3000 series, the RTA4000 series also
uses a slightly different dialect than other previously
supported models, in particular when it comes to the POD
(logic channel groups) handling.

I do not have such model available for testing therefore, as
for the RTB2000 and RTM3000 support recently introduced, I do
not know whether or not the RTA4000 also understands the
existing dialect. In doubt, the new official dialect is
implemented by this patch.
2019-07-26 00:11:07 +02:00
Guido Trentalancia aac3063300 hameg-hmo: Add RTB2000 and RTM3000 MSO support (untested).
According to the latest available version of the manual, they
both use a slightly different dialect than currently supported
models, in particular when it comes to the POD (logic channel
groups) handling.

I do not have any of the above models available for testing
therefore I do not know whether or not they also understand
the existing dialect. In doubt, the new official dialect is
implemented by this patch.
2019-07-26 00:11:07 +02:00
Guido Trentalancia 3a247d0359 hameg-hmo: Add SR_CONF_LOGIC_ANALYZER drvopt. 2019-07-26 00:11:07 +02:00
Guido Trentalancia 4f3cb1eaf7 hameg-hmo: Fix the upper limit for the vertical scale. 2019-07-26 00:11:07 +02:00
Guido Trentalancia 1203acc78f hameg-hmo: Only update states after successful SCPI SET.
Update the oscilloscope state with new settings only after
they have been successfully stored in the device to avoid
an inconsistent state in case of SCPI SET command failure.
2019-07-26 00:11:07 +02:00
Guido Trentalancia 39e1972347 hameg-hmo: Fix for an incorrect samplerate being returned.
The hameg-hmo driver returns an incorrect sample rate: to reproduce this
bug, set the maximum sample rate from the ACQUIRE menu.

This patch fixes the driver so that the correct sample rate is returned.
2019-07-26 00:11:07 +02:00
Guido Trentalancia 3883934404 hameg-hmo: Avoid bogus SCPI timeouts.
During the initial configuration phase of the hameg-hmo driver
only send an OPC command if a SCPI command has been previously
sent to the device so that bogus SCPI timeouts are avoided.
2019-07-26 00:11:07 +02:00
Guido Trentalancia 262061ff3d hameg-hmo: Use 1-based (not 0-based) POD numbers.
The current starting index for the POD name is currently wrong as it is zero.

The official POD numbering starts instead at 1 (see device panel, buttons
and manual), so the current index used for message printing and groups
naming in the driver needs to be incremented by one.
2019-07-26 00:11:07 +02:00
Guido Trentalancia 830e24b68f hameg-hmo: SR_CONF_LIMIT_SAMPLES/_FRAMES don't support _GET.
The samples and frame acquisition limits are not stored in the device or
elsewhere. Therefore they should not be read.
2019-07-26 00:11:07 +02:00
Guido Trentalancia 673989692c hameg-hmo: Avoid a double-free.
Avoid double memory freeing leading to segmentation fault in when a SCPI
command fails to get a string due conditions such as a timeout or an invalid
command.
2019-07-26 00:11:07 +02:00
Guido Trentalancia 4fa4db2c79 hameg-hmo: Add SR_CONF_TRIGGER_PATTERN support.
Introduce support for the Pattern Trigger functionality, sometimes also
called Logic Trigger.
2019-07-26 00:11:07 +02:00
Guido Trentalancia c8ecfa6ea4 hameg-hmo: When setting slope, also set trigger type to edge.
When setting the type of slope for the edge trigger function, also set the
trigger type to edge because it is not necessarily configured that way and
therefore such functionality might fail to work properly!

This fixes parts of bug #1328.
2019-07-26 00:11:07 +02:00
Guido Trentalancia 4cf90b8667 hameg-hmo: Add support for the HMO1202 MSO. 2019-07-26 00:11:07 +02:00
Guido Trentalancia e35ebc6aa3 hameg-hmo: Initial R&S RTC1000 MSO support attempt.
(might need testing)
2019-07-26 00:11:07 +02:00
Guido Trentalancia e131be0ac3 hameg-hmo: Add support for SR_CONF_LOGIC_THRESHOLD/_CUSTOM.
Update the Hameg/Rohde&Schwarz HMO driver (hameg-hmo) so that it
is possible to configure the logic threshold for digital signals.

The user can get or set the logic threshold configuration using
the channel group POD0 (and/or POD1 where available), for example:

sigrok-cli --driver hameg-hmo --get logic_threshold -g POD0
sigrok-cli --driver hameg-hmo --config logic_threshold=TTL --set -g POD0

sigrok-cli --driver hameg-hmo --get logic_threshold_custom -g POD0
sigrok-cli --driver hameg-hmo --config logic_threshold_custom=0.7 --set -g POD0
2019-07-26 00:11:07 +02:00
Guido Trentalancia 3308450089 hameg-hmo: Update the default serial port options.
Update the default serial port options for Rohde&Schwarz and
Hameg mixed-signal oscilloscope devices connected through USB.

Also, remove misplaced and unused serial port configuration option.

This patch complements fa3d104f17
in terms of updating the USB PIDs for new devices (HMO series).

This fixes parts of bug #1321.
2019-07-26 00:11:07 +02:00
Guido Trentalancia d779dcacb7 hameg-hmo: Add SR_CONF_LIMIT_SAMPLES support.
At the moment only the maximum number of frames to be acquired can be
configured for the Hameg/Rohde&Schwarz HMO mixed-signal oscilloscope
series driver (hameg-hmo).

This patch adds support to configure the number of samples to acquire
in both analog and digital (logic) mode.
2019-07-26 00:11:07 +02:00
Guido Trentalancia 6d0f3508f7 hameg-hmo: Add support for 16 digital (logic) channels.
This patch introduces the support for 16 digital (logic) channels for the
following oscilloscope models: HMO3032, HMO3042, HMO3052 and HMO3522
(previously only 8 digital channels were supported, i.e. only 1 POD).
2019-07-26 00:11:07 +02:00
Guido Trentalancia 91525636a6 hameg-hmo: Remove invalid HMO2522, add missing HMO3522.
This patch takes care of removing an invalid product model (HMO2522)
and adds a missing product model (HMO3522) in the hameg-hmo driver,
thus extending the number of supported oscilloscope models.

This fixes bug #1322.
2019-07-26 00:11:07 +02:00
Guido Trentalancia 14cb6aa40a hameg-hmo: Use g_byte_array_free() instead of g_free().
Use the appropriate glib function to free memory (byte array).

This fixes bug #1324.
2019-07-26 00:10:35 +02:00
Uwe Hermann 80d3497569 hantek-4032l: Fix broken triggering on low signal.
The trigger range/mask "compression" procedure is apparently not
required and breaks triggering on a low line state.

This has been verified to fix the issue on a Hantek 4032L with FPGA
version 0x4303. It is possible that the procedure mentioned above
might be required for other FPGA versions, though that is unknown.

If you experience trigger issues with other FPGA versions, please
contact us for further debugging and testing.

This fixes bug #1402.
2019-07-06 23:22:47 +02:00
Uwe Hermann e6bb2984e9 hantek-4032l: Cosmetics. 2019-07-06 23:21:22 +02:00
Nadav Mavor 744d683ca7 rigol-ds: Add Agilent DSO1000B series IDs 2019-07-06 16:54:26 +02:00
Mike Walters 0b0f40d864 scpi-pps: Support HP 66312a 2019-07-03 12:43:18 +01:00
Gerhard Sittig cb5cd1538f serial-lcr: add support for packet request
Some meters require the reception of a request before they provide
acquisition data. Add support for the chip driver's .packet_request()
routine, and timeout handling in the serial-lcr driver. This follows
the serial-dmm model.
2019-06-20 16:45:36 +02:00