For some reason, when calling python and giving a full filename script, the last separator in the filename
must be '/', not '\'.
Otherwise the import command inside the script does not find files to import in the same folder as the script.
We cannot replace blindly '\' to '/' in command line because it does not work for file on a server (name starting by \\server_name\).
So the fix is just replacing one '\' in python script full filename.
This is not perfect, but at least it works for newly created plugin commands.
Spice netlist exporter processes all texts on the exported schematic
sheet to find spice directives and include them in the output file.
By default it also added ".title KiCad schematic" in the first line, so
if there was another .title directive in the exported schematic sheet,
the generated file would contain two .title directives.
This patch looks for .title directive and when one is found - it uses
the specified title in the first line.
This is the last of the object save/load code that was not moved into
the SCH_LEGACY_PLUGIN object. All schematic and library I/O is now
performed in the SCH_LEGACY_PLUGIN object and as been removed from the
schematic and library objects.
The old single symbol file format has been replaced with the normal
symbol library file format since there was no difference between them
except the SYMBOL token. The SYMBOL token was no longer being read
since the introduction of the SCH_LEGACY_PLUGIN symbol library loader.
Update the Doxygen comments in all of the modified files.
SEARCH_STACK is a deprecated method for getting the list of paths where
one could look for a file. Instead it tries the project path and
environmental variables.
Simplify some of the library editing code. There have been a few minor
changes in the behavior of the editor. If the current symbol is deleted
from the library, the next symbol in the library is not loaded. The
deleted symbol is cleared and the current symbol is empty.
Change component to symbol to align with the preferred terminology
discussed on the developer's mailing list.
Add separate update UI event for save library as to enable the menu entry
whenever a library is selected.
Change the select symbol list dialog to a single column using the LIB_ID
format LIB_NICKNAME:LIB_ITEM_NAME so that the selection can be parsed by
LIB_ID.
Add method to expand URI to LIB_TABLE_BASE.
Override wxApp::OnExceptionInMainLoop() in debug builds to make debugging
easier when an unhandled exception occurs in a wxUpdateUIEvent handler.
Change SCH_SCREENS::HasNoFullyDefinedLibIds() to return false when the
schematic has no symbols to prevent the remapping dialog from being run.
Use SCH_COMPONENT part reference when creating netlist rather than looking
up the library symbol.
(On windows, xsltproc.exe does not accept '\' in output filename, only '/' like on Unix, so this separator is converted when possible)
Minor code cleanup
- pad names are stored as wxString instead of a char[4] & integer union
- removed pad name to string conversion functions
- fixed pad & pin properties dialog restrictions regarding the name
length
This commit was too broad and not cognizant of the purpose of the class
UTF8.
Add MAYBE_VERIFY_UTF8() macro, which can trap non-UTF8 encoded strings in
debug builds.
Use that macro conditionally in class UTF8 to trap non-UTF8 encoded strings
being put into UTF8 instances.
Sadly, each unit of a component can have its own unique fields. This
change finds the last non blank field and records it. Last guy wins
and the order of units occuring in a schematic hierarchy is variable.
Therefore user is best off setting fields into only one unit. But this
scavenger algorithm will find any non blank fields in all units and use
the last non-blank field for each unique field name.
Fixes lp:1471417
https://bugs.launchpad.net/kicad/+bug/1471417
Allows to map nodes to pins for Spice models that have more pins than
corresponding schematic symbol. An example is a MOSFET model containing
gate, source, drain & body, whereas schematic symbol part has only gate,
source & drain with body and source connected inside the part.
Use LIB_ID instead of wxString for storing the library symbol information
in the schematic symbol in preparation for the upcoming symbol library table
implementation.
Change the FindLibAlias and FindLibPart functions in the PART_LIBS object
instead of wxString. Please note that only the library ID name is used to
search the list of libraries. The library nickname is ignored. Once the
symbol library table is implemented and full LIB_IDs are defined, the
library search code will no longer be used and will only be kept to load
older schematics that have not been converted.
Move SCH_LEGACY_PLUGIN_CACHE definition so that the legacy plugin knows
how to properly delete the cache object.
netlist generation: remove option "replace IC and U ref by X" (broken option).
All component refs are now prefixed by the Spice_Primitive field value.
Therefore the netlist used by Kicad ngsipce simulator and the spice netlist generated from dialog are the same.
(note: like previously, forbidden chars like ( and ) are replaced by _ in netnames)
This commit creates more issues than resolves. It could happen that
there are components with different reference types (e.g. U1 and IC1)
that would be later converted to X1, causing a conflict.
* Derive SCH_SHEET_LIST from std::vector rather than using internal array
management. Change all internal code to use iterators or array operator
in loops.
* Allow creation of empty SCH_SHEET_LIST for external population for plotting
and printing.
* Clean up print an plot code to take advantage of new SCH_SHEET_LIST behavior.
* Make BuildSheetList() public so list can be populated after creation.
* Update all instances of SCH_SHEET_LIST with the appropriate SCH_SHEET
object on initialization.
* Create const and non-const version of SCH_SHEET_PATH::GetSheet().
* Add sheet number that is set by schematic file load order. This duplicates
the previous SCH_SHEET_PATH behavior.
* Uncouple SCH_REFERENCE and SCH_REFERENCE_LIST from SCH_SHEET_PATH.
* Add - operator to SCH_SHEET for comparison purposes. This duplicates the
behavior of SCH_SHEET_PATH::Cmp().
* Uncouple SCH_COMPONENT::GetRef() from SCH_SHEET_PATH and use SCH_SHEET
instead.
* Uncouple SCH_COMPONENT::GetUnitSelection() from SCH_SHEET_PATH and use
SCH_SHEET instead.
* Fix all calls to GetRef() and GetUnitSelection() to pass a pointer to the
appropriate SCH_SHEET object instead of an SCH_SHEET_PATH object.
* Add code to SCH_SHEET object to clear annotation.
* Change SCH_COMPONENT::GetPath() to derive path from SCH_SHEET object instead
of SCH_SHEET_PATH object.
* Remove clear annotation code from SCH_SCREENS object.
* Remove global s_NetObjectslist.
* Separate out non-owning version of NETLIST_OBJECTS_LIST into NETLIST_OBJECTS.
* Fix double free pertaining to ~NETLIST_READER().
* Remove all file-io from CvPCB.
* Remove exe launcher cvpcb, retain only cvpcb.kiface, since cvpcb.kiface has no file i/o.
* Add void CVPCB_MAINFRAME::KiwayMailIn( KIWAY_EXPRESS& mail ) and teach it to use old
netlist loading code with a STRING_LINE_READER LINE_READER.
* Fix BEGIN_EVENT_TABLE( CVPCB_MAINFRAME, KIWAY_PLAYER )
This is due to the fact static strings flagged translated ( _("string") notation) are not translated when they are static only if they are not inside a dll.
When they are static inside a dll, the dictionary is already loaded, and the constructor translate them.
Therefore they can be translated twice in dialogs are calling wxGetTranslation to show them, if the application is run from kicad.
But if the application is run as stand alone, the translation is made only once (as expected).