Previous assumption of 100mil grid in CADSTAR schematic designs has
been proven to be incorrect. Let's use the "working grid" in the
original design instead.
- Rename member variable names to use the 'm_' prefix
- Rename a few object types that clashed with KiCad object names, such
as BOARD and SCHEMATIC, to avoid the use of '::' to access the KiCad
objects.
- Remove some unused code.
Vertex memory allocation uses malloc and realloc without checking the
result. Throw exceptions that can be caught in the DoRepaint() method
in EDA_DRAW_PANEL_GAL when malloc and realloc return a null pointer.
Add a reset button that will only show up if the user
edits the JSON configuration for grids. This is a temporary
measure until we have a real grid editor GUI in V7.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7595
- remove ${COMMENT0}, that was broken (returned the same as ${COMPANY}.
- So ${COMMENT1} to ${COMMENT9} are only recognized for Comment1 to Comment9
in page settings dlg, and are equivalent to our old %C0 to %C8 format string
- fix a minor coding style issue.
Fixes#7642https://gitlab.com/kicad/code/kicad/issues/7642
- Make DIALOG_SHIM::SetPosition working)
- rename PCB_BASE_FRAME::SelectLayer() to PCB_BASE_FRAME::SelectOneLayer()
- PCB_BASE_FRAME::SelectOneLayer(): make dismiss dialog by escape key working.
Fixes#7578https://gitlab.com/kicad/code/kicad/issues/7578
When switching schematics that causes an error message (for example if
the schematic needs repair), wx can refresh in between view updates,
leading to a null preview.
On mac, the backspace key is commonly used from removing items. The
forward delete key doesn't really exist (it is hidden behind
fn-backspace), so this modifies our common use of delete. The
context-dependent usage in router and polygon creation are unaffected as
CONTEXT overrides GLOBAL when processing
* Fix multi line text alignment.
* Parse schematic frame objects and convert them to lines.
* Make implicit global labels normal size so they can easily be seen.
* Move sheet fields to a more sensible position.
* Parse schematic symbol instances before wires so that the implicit power
connections can properly be tested. This will be used at a later time.
* Scale label text size down to allow for differences in label offset and
graphical items.
For some kinds of issues, we want a way to point them out but
we don't need to keep the user from being able to close the
dialog. A separate Validate button lets the user check for
issues if desired, but these issues are not "fatal" and can
be ignored if the user wishes.