Now that we are dealing with individual connection elements that do not
update their connected elements as well, we can thread the update, just
being careful to guard any remaining updates (bus_enty/busLine) that
need reciprocal updating
Fixes https://gitlab.com/kicad/code/kicad/issues/10974
(cherry picked from commit 6a53e318e5)
If the SCH_ITEM has already been processed, the extra time needed to
iterated over the memberset and get the SCH_CONNECTION when we won't use
it is not neccesary.
Fixes https://gitlab.com/kicad/code/kicad/issues/10974
(cherry picked from commit 776a28a10e)
Normally, you will gain by resursing a nested loop only over the
pairs that are not already handled. In this case, however, you lose
time because you step outside of the cache by adding the reciprocal test
at each step.
Instead, we process one element at a time, keeping it cached and loop
over all other elements to add to the connection. This saves us about
75% of the time for larger loops (e.g. stacked power pins on a large
BGA)
Fixes https://gitlab.com/kicad/code/kicad/issues/10974
(cherry picked from commit 3a98eacdb9)
Fixes:
* Various special cases around junctions on pins and dragging.
* Some rotations of endpoints resulting in a 45 degree rotate.
* Some cases where it was possible to get a line with neither
endpoint selected, and also substractive unselecting only one of two
selected endpoints unselecting both.
* Use line midpoint for sorting. Start and endpoints aren't
consistent in the order they appear on the X or Y axis. So,
we need to use the midpoint for our position for consistent
sorting when dragging groups of parallel lines where some
have the start and end reversed.
Other:
* Rename TEMP_SELECTED TO SELECTED_BY_DRAG. This is the actual meaning
of the flag, and should reduce confusion as
to when it should be used.
* Move usage of TEMP_SELECTED as an algorithmic mark to CANDIDATE
instead.
* Fix mistaken clearing of START_POINT and ENDPOINT.
* Move endpoint setting and clearing out of narrowSelection, and into
selectPoint and selectMultiple.
* Don't show dangling end warnings on new lines
In symbols, a polyline descr is already a true polyline / polygon descr.
In schematic, a polyline descr was restricted to only 2 points (a line).
A true polyline / polygon descr is now allowed in schematic that support already
polygons.
For compatibility reason, a 2 points polygon (SCH_SHAPE) is converted to a SCH_LINE.
MapAngles() will modify parameters and C++ does not guarantee LTR
evaluation, so we need to separate the calls into the proper order
before comparing the returns
Fixes https://gitlab.com/kicad/code/kicad/issues/11135
Do not use the symbol field string to populate the value and footprint
grid cells. The field strings may be empty because the symbol has not
been instantiated yet by entering a sheet. This fix makes an incorrect
assumption that the first instance value and footprint data in the symbol
is the same for all instances.
Note: this fix is incomplete because the value and footprint fields are
can now be different between sheet instances. The entire field
table editor design will need to be rethought because the current
grouping doesn't allow different value and footprint instance
changes.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11194
Previously, coordinates were clamped to +- 60 inches. It makes no sense to
clamp them at plotter level: max cooed depends on the editor (schematic/board...)
Rename MAX_PAGE_SIZE_MILS to MAX_PAGE_SIZE_EESCHEMA_MILS and use it only for Eeschema.
Fixes#11196https://gitlab.com/kicad/code/kicad/issues/11196
There was also a logic bug when the selected schematic was in a different
path than the current project and was already part of the current project.
The symbol library table reconciliation code was still run which was wrong.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11075
SPICE simulator can be called also during IBIS model determination,
and in the future in ERC. Therefore a necessity arises to implement
exclusive access.
We want to shorting the processing time by marking symbols that have
already been processed. But we must avoid marking symbols that will not
be processed due to their other flags
Fixes https://gitlab.com/kicad/code/kicad/issues/11164
(cherry picked from commit 2208e0db16)
Needed to find bottlenecks in fns, so break out individual sections of
the massive function for easier understanding.
buildItemSubgraphs (one section of the previous function) would build
millions of connections that were never used as stacked pins created X!
connections. Also tested using sets instead of lists and keeping unique
lists to avoid flagging but none of these were as performant as using
flags to remember which items had already been processed.
Fixes https://gitlab.com/kicad/code/kicad/issues/10974
(cherry picked from commit 17b1b68ac7)
The previous solution cleared all of the fields and force the unit setting
to unit one which would have less than desirable effects when reusing a
schematic in another project. This solution forces all of the instance
settings to the first sheet instance of the current project to prevent file
change churn when changing shared sheets in the current project.
This will not prevent shared schematic file changes when the first sheet
instance data differs between projects.
Also make sure that value field is updated from name changes when the
symbol is a power symbol (even if it's from the schematic instead of
the library).
Fixes https://gitlab.com/kicad/code/kicad/issues/11093
Double-calls are no longer needed when using settings. They can
interfere depending on how the system executes the commands.
Removing keeps the last used plugin as the default, rather than the last
selected
Fixes https://gitlab.com/kicad/code/kicad/issues/11094
(cherry picked from commit e8ef863861)
Adding a page in the ctor can generate events that change the default
page. Instead, we set the default after all pages have been added,
avoiding the reset
Fixes https://gitlab.com/kicad/code/kicad/issues/10910
(cherry picked from commit 5314ba6440)
Avoid excess writes to the project directory to dodge issues with remote
file systems not fully writing data.
wxRename works across disk boundaries (in theory) and falls back to
wxCopy/wxRemove when it fails
Fixes https://gitlab.com/kicad/code/kicad/issues/10747
MapAngles will adjust by small amounts the angles t1 and t2. This
adjustment will determine the CW/CCW drawing. Therefore, the MapAngles
needs to be called explicitly before the Normalize180() call.
Left-to-Right evaluation is not a given for MSVC
Fixes https://gitlab.com/kicad/code/kicad/issues/11050
Arcs can be altered by the process of changing from on-disk
representation to in-memory representation. Saving back to disk without
modifying the arc should not modify the calculated values.
This stores a copy of the on-disk representation that is only used to
save back to disk in the event that the arc is not modified during
editing.
Fixes https://gitlab.com/kicad/code/kicad/issues/10442
When double-clicking to open a symbol, it is no longer selected in the
tree. We need to use the `GetTargetLibId()` to pick the correct symbol
(first selected, then current) when using the duplicate command
Fixes https://gitlab.com/kicad/code/kicad/issues/11034
(cherry picked from commit 802d20c409)
Before they were 1/2 treated as flags and 1/2 treated as a mode enum.
The ERC flag relaxes constraints on data that is settable in the
schematic editor.
Fixes https://gitlab.com/kicad/code/kicad/issues/11018
It hasn't worked since we rejiggered the default grid selection mode
anyway, and for some reason it eats <esc> key events after the dialog
has been resized.
Fixes https://gitlab.com/kicad/code/kicad/issues/11015
The fix for https://gitlab.com/kicad/code/kicad/issues/10529 kicked the
subsequent IDs for unit selection off the maximum ID value for popup
menus. This increases the maximum popup number (integers are free)
(cherry picked from commit 79b6991d7b)
Removes the ability to hide symbol units in file formats. This was
mostly the case for a while but there remained corner cases where we
left a default/hidden option
Fixes https://gitlab.com/kicad/code/kicad/issues/10888
When reading sheet fields, we need to maintain a consistent order for
the mandatory fields as they are dereferenced by place. We force this
during the `SetFields()` call.
(cherry picked from commit 8385ce3021)
We need to keep the screen blank while initially loading a sheet before
the hierarchy is developed. Avoid resolving text variables during this
process
Fixes https://gitlab.com/kicad/code/kicad/issues/11000
(cherry picked from commit 63b06af6b1)
Center rotation will often misalign lines to the grid, which is bad
until fix off grid items on the schematic.
We can rotate a connection end into a new connection or to become
collinear with an existing line, so we need to check for this at the end
of rotation.
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/10565
(cherry picked from commit 7d4cb91f39)