This fix required sorting all of the LIB_PART draw items to ensure
accurate comparison between the symbols stored in the schematic and the
original library symbols. This has a noticeable impact on symbol library
load performance. It may also cause significant changes the next time
the library is saved due to changes in the draw item sorting. Hashing
may be a better solution here but this addressed the immediate problem.
A skeleton method SCH_SCREEN::SwapSymbolLinks() was added because there
is most likely an issue with orphaned symbols in the schematic library
symbol cache during undo/redo operations. More testing is required to
verify this.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7263
Adds Tom's internal P&S debugging tool. This is a work in progress and the code is quite messy for the moment, but I can't keep it in private branches forever and waste time rebasing it.
Note: experimental and *very unclean* code. Use at your own risk.
Now that footprint properties inherit custom fields from schematic
they are very useful.
Setting custom properties from python will also be handy in plugins
that need to somehow mark their own objects.
The nettie hack is used in DRC but we also need to use it in zone filler
to allow zones to be used with netties. We limit this to the
appropriate nets in the nettie
Fixes https://gitlab.com/kicad/code/kicad/issues/7351
This way the net names can be inspected in eeschema and cross-probing works.
Testcases updated for the name changes
CHANGED: all unconnected pins are now included in the netlist with no_connect_ prefixes
This behavior provided shorter net names, but was confusing if
the user gives an explicit strong driver in the subsheet but not
one in the parent sheet.
Testcases updated for net name changes; connectivity is the same
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4201
Depending on what order the subgraphs are processed in, it's
possible to hit a case where the parent sheet renames a bus
member before the bus neighbor renaming logic runs. In this
case, we don't want to apply the bus neighbor logic as it will
break connectivity to the parent sheet if that bus was not
also renamed (for example, if the hier ports only make net
connections and not bus connections)
Fixes https://gitlab.com/kicad/code/kicad/-/issues/6887
In particular, there was a typo that kept library values from being
updated, and there was missing logic to fetch the various field names
from the library parts (and the change-to part).
Also implements some performance gains by desisting from copying
LIB_FIELDs around every time we want to look at them.
Fixes https://gitlab.com/kicad/code/kicad/issues/6733
Fixes https://gitlab.com/kicad/code/kicad/issues/6749