We have a dialog shim that raises the ERC dialog in front of the
schematic frame, which is useful for keeping the ERC dialog visible
during debugging. But mouse move events do not pass through to the
schematic, resulting in a captured mouse pointer but no drawing updates.
As a work-around we close the ERC dialog while placing new components.
Previous ERC data still exist when the window is launched again.
Fixes: lp:1779851
* https://bugs.launchpad.net/kicad/+bug/1779851
Missing types were handled by the superclass (in the case of zones)
PCB_CONNECTED_ITEM, which incorrectly returned "true" when testing lines
against zones.
Fixes: lp:1789195
* https://bugs.launchpad.net/kicad/+bug/1789195
Before closing the window in the footprint editor, we clear the existing
pcb, undo/redo stack and associated memory to prevent callbacks
double-freeing on destruction.
Fixes: lp:1784504
* https://bugs.launchpad.net/kicad/+bug/1784504
The default board soldermask clearance should not be used in the
footprint viewer. Setting the board's solder mask margin to 0 will
leave the footprint displayed with only the soldermask defined by
the pads or the footprint.
Thanks to Fabian Inostroza for pointing out the missing line.
Fixes: lp:1779979
* https://bugs.launchpad.net/kicad/+bug/1779979
The Boost folks kindly decided to move the sha1.hpp header file location
so check the Boost version to include the proper header path.
Clean up debug trace code.
Also fixes a bug where nets wouldn't get changed because the
pads weren't changed and so the pad nets would propagate and
wipe out the changed nets on the tracks.
Also includes warning dialogs that pad nets will be changed if the
track nets are.
Fixes: lp:1779854
* https://bugs.launchpad.net/kicad/+bug/1779854
Previous tooltips were outdated. Current action is to center with
single-click, hightlight with right-click and close window with
double-click.
Fixes: lp:1788635
* https://bugs.launchpad.net/kicad/+bug/1788635
Use standard Magnetize() to handle grid and magnetic pads.
Use the standard menu from PCB_TOOL. Delegating the menu to
the SELECTION_TOOL just caused grief.
Also brings clients (such as Position Relative To) into line,
and implements better Cancel behaviour.
Also improves visibility of modal status messages:
- moves Select Anchor message from status bar to popup
- moves Select Reference message from dialog to popup
Fixes: lp:1786727
* https://bugs.launchpad.net/kicad/+bug/1786727
It was only a overzealous (in this case) assert, with no issue.
The fix avoid calling DeleteAll() when there is nothing to delete.
Fixes: lp:1787810
https://bugs.launchpad.net/kicad/+bug/1787810