Eeschema shows background fills on a different z-level than the rest of
the symbols/elements. Print the backgrounds prior to the foregrounds in
order to preserve this view for print output
Fixes https://gitlab.com/kicad/code/kicad/issues/12559
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Added project name to instance data to improve the readability of the
schematic file format. It also creates an opportunity to remove orphaned
instance data by project name rather than cryptic UUIDs.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
The commit bumps the schematic file format version in order to fix the
initial symbol default instance data to the first instance of each symbol.
It also sets the initial instance data to undefined in the SCH_SYMBOL
ctor so on the first schematic save, the default instance will be set
to the first instance of the symbol.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12190
The legacy and s-expression (prior to version 20200828) file formats only
supported symbol unit and reference fields so the newly added value and
footprint fields must be updated from the original symbol fields.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12226
Also fixes some plot bugs with arcs.
Also moves polygonization of arcs (when required) in plotting code
from 5 degrees to calculated based on ARC_HIGH_DEF.
Fixes https://gitlab.com/kicad/code/kicad/issues/5017
Remove duplicate instance data saved in both root SCH_SCREEN and SCH_SHEET
objects that was causing them to be out of sync. All sheet instance data
is stored in the SCH_SHEET object itself and rebuilt on the fly so it is
always current.
Remove Get/SetPageNumber from SCH_SHEET_PATH object so it doesn't obfuscate
where the actual sheet page number information exists.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/9782
The tests for file existence and write status perform two file stats
which cause performance issues on slow network shares. Now the file
state is determined at load time and stored in the SCH_SCREEN object
so file access is no longer required.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/9343
When swapping SCH_SYMBOL objects during undo, no special processing is
required. The SCH_PIN objects are updated when the LIB_SYMBOL objects
are swapped and the call to SCH_SCREEN::SwapSymbolLinks() didn't do
anything.
They don't define a KiCad string class, so the header file name was
somewhat misleading. But the fact that they didn't match definitely
made coding more difficult.
Found via `codespell -q 3 -S *.po,./thirdparty -L aactual,acount,aline,alocation,alog,anormal,anumber,aother,apoints,aparent,aray,dout,einstance,modul,ot,overide,serie,te,,tesselate,tesselator,tht`
Differentiates better between the EDA_ITEM IsModified(), referring to
items themselves changing and the EDA_SCREEN IsContentModified(),
referring to whether we have made any unsaved changes.
This fix required sorting all of the LIB_PART draw items to ensure
accurate comparison between the symbols stored in the schematic and the
original library symbols. This has a noticeable impact on symbol library
load performance. It may also cause significant changes the next time
the library is saved due to changes in the draw item sorting. Hashing
may be a better solution here but this addressed the immediate problem.
A skeleton method SCH_SCREEN::SwapSymbolLinks() was added because there
is most likely an issue with orphaned symbols in the schematic library
symbol cache during undo/redo operations. More testing is required to
verify this.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7263
Junctions should only be wire endings when ending directly on the wire.
This is the requirement for netlisting, so we need to follow it in the
auto-end as well.
SCH_LABEL needs to allow ending because any wire that touches the label
will be connected, so there's a use case for this. However, the
bounding box for local labels did not include their connection point, so
we increase that box a bit. Note that this might have the opposite
effect to https://gitlab.com/kicad/code/kicad/-/issues/7689
Fixes https://gitlab.com/kicad/code/kicad/issues/7714
This also makes sure that the user gets a warning before saving over
an older s-expr format. While that won't always be wanted, it's now
in the infobar (like in PCBNew), so it's not too onerous.§
Fixes https://gitlab.com/kicad/code/kicad/issues/7347
The variable `m_Initialized` in `BASE_SCREEN` is used by
`SCH_EDIT_FRAME` to mark whether a screen had its zoom level initialized
by the "zoom to fit screen" action. When this variable is `false`, the
function `SCH_EDIT_FRAME::DisplayCurrentSheet()` performs "zoom to fit
screen", modifying the zoom level. This function is indirectly called in
the undo routines, so if `m_Initialized` is not set to `true`, a zoom
change will occur when the user undoes an operation, a behavior that is
undesired.
`m_Initialized` was not initialized to `true` for the null schematic
(the schematic that is loaded if no project is loaded), causing the
aforementioned undesired behavior.
To prevent this, I've changed the `SCH_EDIT_FRAME` constructor to set
`m_Initialized` to `true`, since it zooms to fit screen already. I've
moved `m_Initialized` from `BASE_SCREEN` to `SCH_SCREEN`, as it is used
only in Eeschema, and renamed it to `m_zoomInitialized`, a name I
believe that better describes what this variable does.
I've also introduced the function `SCH_EDIT_FRAME::initScreenZoom()` to
group the "zoom to fit screen" action with setting `m_Initialized` to
`true`, as they often should occur together.
I'd also like to say that I'm not confident whether
`SCH_EDIT_FRAME::DisplayCurrentSheet()` should perform the zoom level
initialization at this point, but I have decided to not change this
behavior for now, as the commit history suggests it's several years old.
Fixes https://gitlab.com/kicad/code/kicad/issues/7343
1) Generalize SCH_ITEM owners (SCH_COMPONENT, SCH_SHEET, and now
SCH_GLOBALLABEL)
2) Generalize hypertext items
3) Use SCH_FIELD autoplace infrastructure for placing intersheet
references
4) Use textVar infrastructure for buildin intersheet references.
As an important side-effect this also fixes the undo issues with
intersheet refs.
The groundwork has now been laid for per sheet instance data. Initially
this only supports sheet page numbers but could be expanded to include
other per sheet instance information.
ADDED: Support for user defined schematic page numbers.
Also fixes a couple of bugs where resolving a textVar reference
to the refDes or unit wouldn't get the correct value in a
hierarchical schematic. (Unlogged.)
Fixes https://gitlab.com/kicad/code/kicad/issues/5397
This was causing junctions to not always be added on wire
segments that overlapped component pins, because the pin
might not be part of the component bounding box before
UpdateLocalLibSymbolLinks() is called. When the bbox
was never updated, these symbols weren't collected by
the rtree query for objects overlapping a point.