- If libusb-1.0 is not found, do not compile in ezusb.c and usb.c since
they require libusb.h. The respective hardware drivers that use
libusb-1.0, and usb.c and/or ezusb.c will be excluded from the build
elsewhere in configure.ac. Rename NEED_EZUSB to NEED_USB.
- Drop the NEED_SERIAL check and always compile in serial.c. This is a
very small chunk of code, it does not depend on any external
libraries that might be missing, and it compiles on all architectures.
Thus there's no need to conditionally include or exclude it.
The currently supported model LAP-C(16032) doesn't support the
samplerates 150MHz and 200MHz which some of the other models have.
Thus, do not report these samplerates to the frontends. E.g. sigrok-cli
should not show them via --show and GUIs should not list them in their
"Samplerates" drop-down.
- Explicitly list .config_get in all drivers for consistency, and set it
to NULL if unused (whether or not a driver implements it is optional).
- List all 'struct sr_dev_driver' entries in the same order in all drivers.
- Move the check whether .config_set/.config_list exist (i.e., are non-NULL)
into sanity_check_all_drivers().
This is a small helper function which sends the SR_DF_HEADER packet that
drivers usually emit in their hw_dev_acquisition_start() API callback.
It simplifies and shortens the hw_dev_acquisition_start() functions
quite a bit.
It also simplifies the input modules which send an SR_DF_HEADER packet, too.
This patch also automatically removes some unneeded malloc/free in some
drivers for the 'packet' and 'header' structs used for SR_DF_HEADER.
Check the relevant arguments for != NULL before calling the actual
driver-specific function, so that the driver can safely assume those
arguments are non-NULL. This removes the need to duplicate these
checks in every driver.
This patch might also work for a number of other Brymen models
-- 859(a), 867, 869---
including their respective rebadges from Greenlee, Extech, and Amprobe.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
Check the relevant arguments for != NULL before calling the actual
driver-specific function, so that the driver can safely assume those
arguments are non-NULL. This removes the need to duplicate these
checks in every driver.
Also, do some minor whitespace and consistency improvements.
Check the relevant arguments for != NULL before calling the actual
driver-specific function, so that the driver can safely assume those
arguments are non-NULL. This removes the need to duplicate these
checks in every driver.
Also, change one SR_ERR to the more correct SR_ERR_MALLOC, and assign
sr_ctx in the rigol-ds1xx2's hw_init() function, like all the other
drivers do.
Sending an SR_DF_META packet at the start of every stream is not
mandatory; the frontend should ask for what it needs, and any extra
information the driver wants to send will come in due time.
Currently hw_info_get() can receive requests for entries (info_id) that
the specific driver doesn't support. That is (right now) a valid
use-case and not an error (might change later, though).
Thus, for now, don't output messages for such requests at all (certainly
not as sr_err() where they show up in e.g. sigrok-cli output per default).
Errors while opening or configuring ALSA devices during scan for devices
should not be shown by default (i.e., no sr_err() usage). Non-working
or non-accessible devices (due to permissions or other reasons) will
simply not show up in frontends. Use sr_dbg() instead of sr_err().
Fix the bare minumum of whitespace/indentation/coding-style via
automatic 'indent' run, followed by some minor manual fixes.
Some more fixes and cleanups might follow later.
Bring back the original (C) lines from before the split into api.c
and protocol.[ch].
Add "Copyright (C) 2013 Lior Elazary <lelazary@yahoo.com>" since there
were nontrivial changes to those files.
Since we are using the 'hw' interface of ALSA, we don't have the luxury of
samplerate conversion, given by the 'plughw' interface. If we try to set a
samplerate that is not supported, ALSA will just throw an error.
We can test for the supported samplerates, and create a list of supported
samplerates, then limit the selection to only those values. The frontend can
query the list of supported samplerates.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
The alsa driver requested signed 16-bit integers from ALSA, but casted them to
to an unsigned 16bit before finally casting them to a float. The end result was
that half of the wave would be clipped off.
We also requested data in little endian format. ALSA can be instructed to send
data with the correct endianness for the platform, without needing to worry
about what that is.
This patch attempts three points, which, together, fix the acquisition:
1) Request data from ALSA without specifying endianness; ALSA will handle the
endianness.
2) Simplify the int16_t to float loop by using straightforward indexes.
3) Normalize every value before sending it on the session bus.
NOTE: If testing with PulseView, it will appear as if sigrok is sending all
zeroes. sigrok is sending correct data, but since the data is normalized,
PulseView will incorrectly plot it as a straight line.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
The alsa driver only works with device "default". This limits the driver's
scope to whatever device ALSA deems to be "default". It is desirable to have
access to all ALSA devices from sigrok.
Change the alsa device scan so that:
Each alsa device (not alsa card) gets its own sigrok device
For example,
hw:1,0 == sigrok device 0
hw:1,1 == sigrok device 1
hw:2,0 == sigrok device 2
hw:2,1 == sigrok device 3
hw:2,2 == sigrok device 4
[...]
We don't currently look at alsa subdevices. We only use subdevice 0.
Every input device will have its own channels (left, right, etc). Each of
those channels gets mapped to a different sigrok probe. A device with 4
channels will have 4 probes from sigrok's perspective.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
snd_pcm_hw_params_set_rate_near() will try to use the samplerate closest to the
given value, potentially starting the acquisition with a different samplerate
than the one specified.
Instead, use snd_pcm_hw_params_set_rate(). It will return an error if the
samplerate is not supported by the hardware, which is arguably better than
collecting data with a different samplerate than the one specified.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
asix-sigma.c:648:9: warning: 'ret' may be used uninitialized in this
function [-Wmaybe-uninitialized]
asix-sigma.c:1337:20: warning: 'triggerselect' may be used uninitialized
in this function [-Wmaybe-uninitialized]
This matches the _ser suffix of the other functions/variables for this
device ("ser" denotes that it is used with the serial UNI-T UT-D02 cable
as opposed the USB/HID based cables which are handled by the uni-t-dmm driver).
But more importantly, the _SER suffix for the enum value will prevent
name clashes later, when the uni-t-dmm driver gets a VOLTCRAFT_VC820 enum.
Do the same for VOLTCRAFT_VC840.
Check whether a sample limit was actually set (> 0) before checking if
that sample limit is reached. This also fixes continuous acquisition mode
for drivers which have that.
Implement SR_HWCAP_LIMIT_MSEC capability, to allow acquisition to automatically
stop after a specified amount of time.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
Some unusual modes required re-parsing the value. Instead of assigning the
re-parsed value to *floatval, it was reassigned directly to *analog->data;
however, analog->data is not initialized at this point, causing a segfault.
This situation was created when moving the radioshack-dmm code to serial-dmm,
with the segfault not being observed at that time.
Do not write directly to analog->data, but instead use the intermediate
variable rawval.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
Convert bit masks from hardcoded hex values to bit shifts. For example 0x80
becomes (1 << 7). This also fixes a typo error in the definition of INFO_DIODE.
Add comments explaining that some case values in sr_rs9lcd_parse() are meant to
fall through without a 'break;', and explain some of the unusual modes.
Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
Unfortunately the device doesn't have an EEPROM on board at all, and so
initially enumerates with the default Cypress FX2 VID:PID (04b4:8613).
Since we already support using plain FX2* as basic logic analyzers using
the fx2lafw firmware, we cannot support that same VID:PID for the
OsciPrime. Therefore a USB conn is required for the initial scan.
However, once the firmware is uploaded the device re-enumerates as
04b4:1004, which we do detect for scanning automatically.
Thus, the OsciPrime driver requires one scan with conn parameter to get
the firmware uploaded, but it will then keep working until powered off.