Currently, kicad_pcb files have a (version ...) tag, but it is ignored. This
commit does the following:
1. Parse the version. If it's later than the last supported version, present an
alternative error message suggesting an upgrade if the file does not load
correctly. The version will be interpreted as an integer YYYYMMDD to suggest
a KiCad release date.
2. Accept a (version ...) tag also in kicad_mod files, but do not write them
yet. If no version tag is present in these files, assume the version to be that
of the current format version at the time of this commit.
This is meant to be merged to the 4.x stable series, and preps for KiCad 5
which will start emitting version tags also in footprints - users with what
will then be 'old stable' will not get a parse error when we introduce this for
footprints, and we can safely increment the format version later.
* Fix a StrPrintf() %s count mismatch bug
* Better comments
* Use std::string::data() instead of a ref to the first char to get the str::string buffer (should not change anything with GNU lib)
PAD_SHAPE_T and PAD_ATTR_T still have a double definition (new names and old names) to be sure python scripts are nor broken by the change.
PAD_DRILL_SHAPE_T does not have a double definition, because it is unlikely oblong holes are used in python scripts.
Double definitions will be removed in the (next) future.
* Cleanup namespace in enum ZoneConnection in pcbnew/zones.h to self-explained names unification: PAD_ZONE_CONN_INHERITED, PAD_ZONE_CONN_NONE,PAD_ZONE_CONN_THERMAL,PAD_ZONE_CONN_FULL, PAD_ZONE_CONN_THT_THERMAL
these options are used in GAL mode, but the usercannot control this visibility. So if the board file does not have these visibility flags set, the GAL never show them.
Fix also a compil warning.
legacy plugin: better compatibility with old brd files (current track width and current vias size, stored in SETUP section, were not read from file and incorrectly set)
* Delete Single Pad Net option does not delete the net if a zone use this net (i.e. is attached to this pad).
* pcb_parser accept now negative netcodes in zones (can happen with old files, which previously could crash Pcbnew)
* pcb_parser accept now files with incorrect or missing net count (can happen with old files, which previously could crash Pcbnew)
* if a zone has a non-existent net name it now keep this net name, and DRC detect it (previously, the net name was lost, and the DRC did not tected this issue).
* Drc test: now detect a "dead" net, i.e. a net with 0 pads, but still used by a zone. It happens easily after a schematic modification, when a net disappears or is renamed.
Looked like a minor issue, but was due to a more serious bug, when using 2 different DSN_LEXERS which were not synchronized.
The fix is not perfect, but unfortunately, the parser used to read the PCB_PLOT_PARAMS in .kicad_pcb files is also used in legacy board file reader.
Therefore it is better than write 2 parser functions, one for legacy files, the other for the .kicad_pcb files, which make the same thing.
*) When kicad.exe closes a project, close any open KIFACEs so that they cannot
get disassociated from their true PROJECT.
*) Allow loading eeschema library editor from kicad.exe
*) Allow loading pcbnew library editor from kicad.exe
*) Rename LIB_COMPONENT to LIB_PART.
*) Add class PART_LIBS, and PART_LIB.
*) Make PART_LIBS non-global, i.e. PROJECT specific.
*) Implement "data on demand" for PART_LIBS
*) Implement "data on demand" for schematic SEARCH_STACK.
*) Use RSTRINGs to retain eeschema editor's notion of last library and part being edited.
*) Get rid of library search on every SCH_COMPONENT::Draw() call, instead use
a weak pointer.
*) Remove all chdir() calls so projects don't need to be CWD.
*) Romove APPEND support from OpenProjectFiles().
*) Make OpenProjectFiles() robust, even for creating new projects.
*) Load EESCHEMA colors in the KIWAY::OnKiwayStart() rather in window open,
and save them in the .eeschema config file, not in the project file.
*) Fix bug with wxDir() while accessing protected dirs in kicad.exe
*) Consolidate template copying into PROJECT class, not in kicad.exe source.
*) Generally untangle eeschema, making its libraries not global but rather
held in the PROJECT.
2) Fix passing wxString to common/config_params so lookup keys
can be dynamically generated. This gives ~/.kicad files all the colors.
3) Fix LEGACY_PLUGIN so it loads all layer types and masks properly.
4) Extend the table in router/pns_index.h to 128 from 64.
2) Change from legacy Cu stack to counting down from top=(F_Cu or 0).
The old Cu stack required knowing the count of Cu layers to make
sense of the layer number when converting to many exported file types.
The new Cu stack is more commonly used, although ours still gives
B_Cu a fixed number.
3) Introduce class LSET and enum LAYER_ID.
4) Change *.kicad_pcb file format version to 4 from 3.
5) Change fixed names Inner1_Cu-Inner14_Cu to In1_Cu-In30_Cu and their
meanings are typically flipped.
6) Moved the #define LAYER_N_* stuff into legacy_plugin.cpp where they
can die a quiet death, and switch to enum LAYER_ID symbols throughout.
7) Removed the LEGACY_PLUGIN::Save() and FootprintSave() functions.
You will need to convert to the format immediately, *.kicad_pcb and
*.kicad_mod (=pretty) since legacy format was never going to know
about 32 Cu layers and additional technical layers and the reversed Cu
stack.
Removed SetCurrentClassName() (it was not used anywhere and less safe than SetCurrentClass()).
Added BOARD_DESIGN_SETTIGNS::GetDefault() to make some pieces of shorter and clearer.
Most of the changes are just adding GetDesignSettings() before every occurence of m_NetClasses.
More complex changes:
class_netclass.cpp - NETCLASS does not store the pointer to the parent BOARD anymore. Added function SetParams( BOARD_DESIGN_SETTINGS& ).
class_netclass.h - Removed GetTrackMinWidth(), GetViaMinDiameter(), GetViaMinDrill(), GetuViaMinDiameter(), GetuViaMinDrill() as they were refering to BOARD_DESIGN_SETTINGS anyway (they are not net class specific).
kicad_plugin.cpp - filters out empty nets (that are anyway not saved) when storing net class information. Previously it was done in NETCLASS::Format() function.
- SEGVIA becomes VIA
- Drill size moved from TRACK to VIA
- Removed shape from TRACK, becomes ViaType in VIA
- GetTrace becomes GetTrack, for uniformity
- Some minor constification and typo fixes
Renamed BOARD_CONNECTED_ITEM::SetNet() -> SetNetCode()
Added BOARD_CONNECTED_ITEM::GetNet() for accessing NETINFO_ITEM* of a given item.
Fixed module editor crash when launched to edit a module from a PCB.
Replaced some BOARD::FindNet( item->GetNet() ) calls with BOARD_CONNECTED_ITEM::GetNet().
Renamed BOARD_CONNECTED_ITEM::SetNet() -> SetNetCode()
Added BOARD_CONNECTED_ITEM::GetNet() for accessing NETINFO_ITEM* of a given item.
Fixed module editor crash when launched to edit a module from a PCB.
Replaced some BOARD::FindNet( item->GetNet() ) calls with BOARD_CONNECTED_ITEM::GetNet().
Added DIMENSION::SetOrigin(), DIMENSION::SetEnd(), DIMENSION::GetOrigin(), DIMENSION::GetEnd(), DIMENSION::GetHeight().
Fixed flipping for DIMENSION class.
Added an information that helps to understand roles of the points in the DIMENSION class.
Some minor changes to PCB_PAINTER (mainly using const COLOR4D& for taking the result of GetColor() function).
Now, nets are saved with consecutive net codes (both modern & legacy plugins).
Zones are saved together with their nets, without depending on the fact if there are any pads with such net. Therefore validation of zone net names was removed (pcbnew/class_board.cpp).
Performed tests:
- Changed a pad's net name from empty to existent - ok, name was changed.
- Changed a pad's net name from empty to nonexistent - ok, error message is displayed, net name stays empty.
- Changed a pad's net name from existent to empty - ok, net name became empty
- Changed a pad's net name from existent to nonexistent - ok, error message is displayed, net name is not changed.
- Drawn a zone that belongs to a net, then modified schematics so the net does not exist anymore. After reloading the net list, all pads/tracks are updated. Zones still belongs to the net that does not exist in the schematic (but still exists in .kicad_pcb file). After running DRC, the zone becomes not filled.
- Undo & redo affects assignment of a polygon to a specific net (you may change net of a polygon, refill it and undo/redo the changes).
- KiCad s-expr & legacy, Eagle, P-CAD boards seem to load without any problem (they also contain correct net names assigned to the appropriate pads). All types of board file formats were loaded, then saved in sexpr format and reopened with a KiCad built from the master branch (without my modifications).
- A few boards were also saved using the legacy format and were opened with the master KiCad without any issues.
- Change a net name for a pad, restore with undo/redo - ok
- Remove everything, restore with undo - ok
- Remove everything, reload netlist - ok
Differences observed between files saved by the master branch KiCad and this one:
- list of nets are not saved in any particular order, so net codes may differ
- the default net class does not contain the unconnected net
GetNet() refers to the net code stored in the NETINFO_ITEM. SetNet() finds an appropriate NETINFO_ITEM and uses it.
Removing GetNet() & SetNet() (and the whole net code idea) requires too many changes in the code (~250 references to the mentioned functions).
BOARD_CONNECTED_ITEMs by default get a pointer to NETINFO_ITEM that stores unconnected items. This requires for all BOARD_CONNECTED_ITEMs to have a parent (so BOARD* is accessible). The only orphaned item is BOARD_DESIGN_SETTINGS::m_Pad_Master, but it does not cause any issues so far.
Items that do not have access to a BOARD (do not have set parents) and therefore cannot get net assigned, by default get const static NETINFO_LIST::ORPHANED.
Performed tests:
- loaded .kicad_pcb, KiCad legacy board, Eagle 6.0 board, P-CAD board - all ok
- load a simple project, reload netlist after changing connections in eeschema - ok
- save & reload a board - ok, but still contain empty nets
- remove everything, restore with undo - ok
- remove everything, reload netlist - ok
- changing net names (all possibilites: empty->existing, empty->not existing, existing->empty, existing->not existing) - all ok
- zones: when net is changed to a net that does not have any nodes besides the zone itself, it does not get filled
- ZONE_CONTAINER::m_Netname field
- ZONE_CONTAINER::SetNetName()
- ZONE_CONTAINER::SetNet() [it uses the one in BOARD_CONNECTED_ITEM]
- ZONE_CONTAINER::GetNetName() [instead BOARD_CONNECTED_ITEM::GetNetname is used]
- ZONE_CONTAINER::SetNetNameFromNetCode()
Performed tests:
- Drawn a zone that belongs to a net, then modified schematics so the net does not exist anymore. After reloading the net list, all pads/tracks are updated. Zones still belongs to the net that does not exist in the schematic (but still exists in .kicad_pcb file). After running DRC, the zone becomes not filled.
- Undo & redo affects assignment of a polygon to a specific net (you may change net of a polygon, refill it and undo/redo the changes).
D_PAD::GetNetname() and D_PAD::GetShortNetname() were moved to BOARD_CONNECTED_ITEM. Now they use the net name stored in NETINFO_ITEM.
Moved some one-line functions from class_board_connected_item.cpp to class_board_connected_item.h.
Added a copyright notice, moved Doxygen comments from class_board_connected_item.cpp to class_board_connected_item.h.
I have some doubts if changes introduced pcbnew/dialogs/dialog_pad_properties.cpp do not break anything, but I could not find a test case that breaks the pcbnew.
Performed tests:
- changed pad's net name from empty to existent - ok, name was changed
- changed pad's net name from empty to nonexistent - ok, error message is displayed, net name stays empty
- changed pad's net name from existent to empty - ok, net name became empty
- changed pad's net name from existent to nonexistent - ok, error message is displayed, net name is not changed
- (re)reading netlists, including net changes - fine, changes are applied, but empty nets are still kept
- loaded pcbnew/pcad2kicadpcb_plugin/examples/CK1202_V1.pcb to test P-CAD import plugin - ok, net names are correct
- imported an Eagle 6.0 board (Arduino Uno; http://arduino.cc/en/uploads/Main/arduino_Uno_Rev3-02-TH.zip) then saved in .kicad_pcb format and reloaded - ok, net names are correct
- saved demos/video/video.kicad_pcb in legacy format and then loaded it again - ok, net names are correct
NETINFO_ITEM::m_Net and NETINFO_ITEM::m_Netname are const.
Changes to be verified:
- pcbnew/minimun_spanning_tree.cpp: It segfaults is m_Size == 0
- pcbnew/exporters/export_gencad.cpp: I removed the SetNetname() call, as it changes only the unconnected net and in the next line it returns if the net is unconnected. Still, I wonder if name for the unconnected net matters. What about tests that check if a net name is empty to decide if it is unconnected net or not.
* When loading footprint do not retest every footprint in cache. Only test
the footprint being loaded. Fixes long load times on libraries with a lot
of parts.
* Fix footprint name bug where file extension was added to the end of the
footprint name.
* Fix bug in path equivalence test due to Posix path separators in footprint
library table. Convert paths to native separator before comparison.
* Fix a bug in FOOTPRINT_VIEWER_FRAME::OnActivate() which cause the footprint
list to always get reloaded when using footprint library tables.
* Remove some unnecessary debugging messages.
* Add a few Doxygen comments to FP_CACHE in kicad_plugin.cpp.
* Use FPID instead of wxString in MODULE object.
* Use FPID instead of wxString when loading and saving files.
* Use FPID in COMPONENT object.
* Add wxString helper functions and comparison operators to FPID.
* Add fp_lib token to pcb and netlist file formats.
* Add code to load and save FPIDs to pcb file format.
* Fix segfault when deleting invalid footprint library tables in Pcbnew
in non footprint library table build.
* Fix bug when counting the number of mod files in
EDA_APP::SetFootprintLibTablePath();
*) add hotkey for setting the grid origin as 'S', in board editor, module editor.
*) re-position the function interface for cursor movement from BASE_SCREEN into
class EDA_DRAW_FRAME. This is a prelude to getting rid of BASE_SCREEN or
splitting it up.
This is limited to round tripping the lines of commented text in the
loading and saving to disk through PCBIO::Format() and PCBIO::Parse().
No editing of the comments is given.
* Fix a bug when full file name and path are passed to FOOTPRINT_INFO::
ReadFootprintFiles() which I created in bug fix lp:593989.
* Fix a wxString debug assertion in EDA_APP::InitEDA_Appl() when the KICAD
environment variable is defined as an empty string.
* Add error dialog when libraries cannot be found in system search path
when loading footprint using the select footprint dialog.
* Add footprint library name column to the EDA_LIST_DIALOG when selecting
footprints from the list.
* Allow reading all columns from the selected row in EDA_LIST_DIALOG.
* Remove redundant sort from EDA_LIST_DIALOG constructor
* Add library name member variable and accessors to FOOTPRINT_INFO.
* Make headers translatable for Eeschema select component from list dialog.
* Add some helper methods to FPID for identifying the FPID type and validity.
* Remove a bunch of trailing whitespace and add missing license comments.
* Complete encapsulation of the ZONE_CONTAINER class.
* Fixed a bug in the EDA_TEXT::Format() default effects behavior due to
improper conversion to internal units and missing test for default
thickness.
* Improved grammar of some Pcbnew context menu strings.
* Moved some more cleverly hidden BOARD object methods into class_board.cpp.
* Lots of coding policy and documentation fixes.
standard layer name support from BOARD::GetLayerName(). This function evolved
in a contorted direction over time, and was being asked to return one of 3
different kinds of layer names, even though it only took a boolean to control
that choice.
Users are better served by forcing them to get to know the concise new
English Standard layer names. This is because these concise names show up
in the "pretty" footprint/module files as the standard representation of
both feature and copper layers.
Change the name of BOARD::GetDefaultLayerName() to GetStandardLayerName().
Drop boolean argument to both BOARD::GetStandardLayerName() and
BOARD::GetLayerName().
* Complete encapsulation of the MODULE class.
* Complete encapsulation of the EDA_TEXT class.
* Encapsulate most of the ZONE_CONTAINER class.
* Add pcbcommon library as a dependency for reSWIGging the scripting
support. This should cover most dependency cases.
* Encapsulate most of the MODULE class.
* Start encapsulating the DIMENSION class.
* Lay some groundwork for EDA_TEXT encapsulation.
* Move cleverly hidden MODULE functions into class_module.cpp.
* Use std::swap to exchange TEXTE_PCB values for undo/redo.
* Remove unused members from MODULE class.
* The usual coding policy and documentation fixes.
* Add check for pad type and force drill size to zero if pad is surface
mount in PCB_PARSER.
* Modify the D_PAD SetAttribute method to clear drill size if pad type is
set to surface mount.
Segment Hit Test: enhanced detection near segment ends (noticeable for instance when clicking on short tracks in Pcbnew.
Remove duplicate code about segment hit test.
remove unused file.