Commit Graph

786 Commits

Author SHA1 Message Date
lelazary eb913174ab Added limit samples Eveything seems to work find up to 1024 samples 2013-01-08 01:00:14 +01:00
lelazary 087a9161ff Rewrote the trigger config. Added trigger position and trigger slope 2013-01-08 01:00:14 +01:00
lelazary 5a24e89ca4 Eveything seems to work now except for triggers. 2013-01-08 01:00:14 +01:00
lelazary 4db2aaffe7 More cleanup. Communication with mso19 is working, but its not triggering. Need to check why. 2013-01-08 01:00:13 +01:00
lelazary 26ddb5baca Added flow control to serial configuration to support xon/xoff for link-mso19 2013-01-08 01:00:13 +01:00
lelazary 4b719338cc Added missing mso functions 2013-01-08 01:00:13 +01:00
lelazary def5c35c4c Removing the old link-mso19 files and changing makefile 2013-01-08 01:00:13 +01:00
lelazary df92e5cf6b Rewrote the link-mso19.c into api and protocol. Still need to test and cleanup some more 2013-01-08 01:00:13 +01:00
Uwe Hermann 29d957ceae rigol-ds1xx2: Cosmetics, whitespace. 2013-01-03 19:04:11 +01:00
Martin Ling fb6e5ba8c7 rigol-ds1xx2: Autoprobe for usbtmc devices on Linux. 2013-01-03 18:41:29 +01:00
Martin Ling 4e108ace13 rigol-ds1xx2: Fix setting trigger parameters. 2013-01-03 18:41:29 +01:00
Martin Ling 542843f76f rigol-ds1xx2: Assorted parameter setting fixes. 2013-01-03 18:41:29 +01:00
Martin Ling e0b7d23ce8 rigol-ds1xx2: First working version.
Currently hardcoded to use /dev/usbtmc1. Analog data readout works.
2013-01-03 18:41:29 +01:00
Martin Ling f4816ac6cc rigol-ds1xx2: Initial driver skeleton. 2013-01-03 18:41:28 +01:00
Uwe Hermann aeabd30820 ols: Implement SR_DI_HWOPTS. 2013-01-03 02:15:27 +01:00
Uwe Hermann 986fde755d serial-dmm: Add UNI-T UT61E support (UT-D02 cable). 2013-01-03 01:13:57 +01:00
Uwe Hermann fe0c0b98c6 Add Cyrustek ES51922 DMM chip parser. 2013-01-03 01:13:06 +01:00
Uwe Hermann 21d3d4ee87 alsa: Add some more samplerates.
Add some more samplerates that seem to be supported by some devices
(found via random grepping of alsa and kernel sources).
2013-01-01 00:37:18 +01:00
Uwe Hermann a1b9a9bf44 alsa: Add missing % for PRIu64. 2013-01-01 00:37:17 +01:00
Uwe Hermann 52ba6e05d5 alsa: Improved error reporting. 2013-01-01 00:37:17 +01:00
Uwe Hermann 721ecf3d97 alsa: Cosmetics, coding style, typos. 2013-01-01 00:37:17 +01:00
Alexandru Gagniuc 65faa197ae alsa: Find supported samplerates during device scan
Since we are using the 'hw' interface of ALSA, we don't have the luxury of
samplerate conversion, given by the 'plughw' interface. If we try to set a
samplerate that is not supported, ALSA will just throw an error.

We can test for the supported samplerates, and create a list of supported
samplerates, then limit the selection to only those values. The frontend can
query the list of supported samplerates.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2013-01-01 00:37:17 +01:00
Alexandru Gagniuc 729850c9e7 alsa: Fix sample acquisition and send normalized values
The alsa driver requested signed 16-bit integers from ALSA, but casted them to
to an unsigned 16bit before finally casting them to a float. The end result was
that half of the wave would be clipped off.
We also requested data in little endian format. ALSA can be instructed to send
data with the correct endianness for the platform, without needing to worry
about what that is.

This patch attempts three points, which, together, fix the acquisition:
1) Request data from ALSA without specifying endianness; ALSA will handle the
endianness.
2) Simplify the int16_t to float loop by using straightforward indexes.
3) Normalize every value before sending it on the session bus.

NOTE: If testing with PulseView, it will appear as if sigrok is sending all
zeroes. sigrok is sending correct data, but since the data is normalized,
PulseView will incorrectly plot it as a straight line.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2013-01-01 00:37:17 +01:00
Alexandru Gagniuc 6944b2d02f alsa: Scan all soundcards and create a sigrok device per input
The alsa driver only works with device "default". This limits the driver's
scope to whatever device ALSA deems to be "default". It is desirable to have
access to all ALSA devices from sigrok.

Change the alsa device scan so that:
Each alsa device (not alsa card) gets its own sigrok device
For example,
    hw:1,0 == sigrok device 0
    hw:1,1 == sigrok device 1
    hw:2,0 == sigrok device 2
    hw:2,1 == sigrok device 3
    hw:2,2 == sigrok device 4
    [...]

We don't currently look at alsa subdevices. We only use subdevice 0.
Every input device will have its own channels (left, right, etc). Each of
those channels gets mapped to a different sigrok probe. A device with 4
channels will have 4 probes from sigrok's perspective.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2013-01-01 00:37:17 +01:00
Alexandru Gagniuc 0d6ff10394 alsa: Do not use snd_pcm_hw_params_set_rate_near()
snd_pcm_hw_params_set_rate_near() will try to use the samplerate closest to the
given value, potentially starting the acquisition with a different samplerate
than the one specified.

Instead, use snd_pcm_hw_params_set_rate(). It will return an error if the
samplerate is not supported by the hardware, which is arguably better than
collecting data with a different samplerate than the one specified.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2013-01-01 00:37:17 +01:00
Alexandru Gagniuc cbc8cbd8bb rs9lcd: Add missing 'break;'
A break was missing for "case MODE_AMP_WIDTH:" in sr_rs9lcd_parse().

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-12-31 22:26:43 +01:00
Uwe Hermann f4abaa9f6b asix-sigma: Fix two compiler warnings.
asix-sigma.c:648:9: warning: 'ret' may be used uninitialized in this
function [-Wmaybe-uninitialized]

asix-sigma.c:1337:20: warning: 'triggerselect' may be used uninitialized
in this function [-Wmaybe-uninitialized]
2012-12-31 21:21:39 +01:00
Uwe Hermann 6375e1c3eb victor-dmm: Fix compiler warning.
protocol.c:106:10: warning: 'factor' may be used uninitialized in this
function [-Wmaybe-uninitialized]
2012-12-31 21:03:45 +01:00
Uwe Hermann f057272cac nexus-osciprime: Fix compiler warning.
protocol.c:26:46: warning: unused parameter 'fd' [-Wunused-parameter]
2012-12-31 21:02:14 +01:00
Uwe Hermann 811155da46 uni-t-dmm: Fix compiler warning.
protocol.c:84:5: warning: 'ret' may be used uninitialized in this
function [-Wmaybe-uninitialized]
2012-12-31 21:01:53 +01:00
Uwe Hermann 6e9d545cf4 rs9lcd: Fix compiler warning.
rs9lcd.c:289:19: warning: 'rawval' may be used uninitialized in this
function [-Wmaybe-uninitialized]
2012-12-31 20:58:14 +01:00
Bert Vermeulen 9116262931 add USBTMC device search helper 2012-12-30 01:44:58 +01:00
Bert Vermeulen 80bc663296 tondaj-sl-814: remove unneeded debugging 2012-12-29 11:19:19 +01:00
Uwe Hermann 2239728c43 ols: Add missing 'extern'. 2012-12-28 17:13:20 +01:00
Uwe Hermann 1476661970 serial-dmm: Rename VOLTCRAFT_VC820 to VOLTCRAFT_VC820_SER.
This matches the _ser suffix of the other functions/variables for this
device ("ser" denotes that it is used with the serial UNI-T UT-D02 cable
as opposed the USB/HID based cables which are handled by the uni-t-dmm driver).

But more importantly, the _SER suffix for the enum value will prevent
name clashes later, when the uni-t-dmm driver gets a VOLTCRAFT_VC820 enum.

Do the same for VOLTCRAFT_VC840.
2012-12-26 02:11:00 +01:00
Uwe Hermann 35e199da50 Fix limit_samples check in various drivers.
Check whether a sample limit was actually set (> 0) before checking if
that sample limit is reached. This also fixes continuous acquisition mode
for drivers which have that.
2012-12-26 02:11:00 +01:00
Uwe Hermann 7869340103 Shorten probe_names[] arrays everywhere.
Also, NULL-terminate all of them.
2012-12-26 00:16:07 +01:00
Bert Vermeulen df36acb36a nexus-osciprime: suppress warnings 2012-12-26 00:02:58 +01:00
Alexandru Gagniuc f9b9bd632f serial-dmm: Handle time-limited acquisition
Implement SR_HWCAP_LIMIT_MSEC capability, to allow acquisition to automatically
stop after a specified amount of time.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-12-25 23:55:42 +01:00
Alexandru Gagniuc 47eda193b2 rs9lcd: Fix segfault with unusual modes.
Some unusual modes required re-parsing the value. Instead of assigning the
re-parsed value to *floatval, it was reassigned directly to *analog->data;
however, analog->data is not initialized at this point, causing a segfault.
This situation was created when moving the radioshack-dmm code to serial-dmm,
with the segfault not being observed at that time.

Do not write directly to analog->data, but instead use the intermediate
variable rawval.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-12-25 23:43:30 +01:00
Alexandru Gagniuc 0853d5e627 rs9lcd: Convenience fixes
Convert bit masks from hardcoded hex values to bit shifts. For example 0x80
becomes (1 << 7). This also fixes a typo error in the definition of INFO_DIODE.

Add comments explaining that some case values in sr_rs9lcd_parse() are meant to
fall through without a 'break;', and explain some of the unusual modes.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
2012-12-25 23:43:02 +01:00
Bert Vermeulen 523dfc2497 nexus-osciprime: basic scanning functionality
Unfortunately the device doesn't have an EEPROM on board at all, and so
initially enumerates with the default Cypress FX2 VID:PID (04b4:8613).
Since we already support using plain FX2* as basic logic analyzers using
the fx2lafw firmware, we cannot support that same VID:PID for the
OsciPrime. Therefore a USB conn is required for the initial scan.

However, once the firmware is uploaded the device re-enumerates as
04b4:1004, which we do detect for scanning automatically.

Thus, the OsciPrime driver requires one scan with conn parameter to get
the firmware uploaded, but it will then keep working until powered off.
2012-12-25 19:09:12 +01:00
Bert Vermeulen 35a078bce5 nexus-osciprime: Initial driver skeleton. 2012-12-24 20:55:23 +01:00
Bert Vermeulen 2f1e5c7cb7 fluke-dmm: Properly handle continuous mode
Same bug+fix as commit d55c89f523
2012-12-24 20:27:45 +01:00
Uwe Hermann dc890b8f9f asix-sigma: Quickfix for an ASIX SIGMA issue.
It's not entirely clear whether this is the right fix, but we're merging
it for now, pending later review.

See also: http://sigrok.org/bugzilla/show_bug.cgi?id=26
2012-12-24 16:57:55 +01:00
Joel Holdsworth b36e715395 fx2lafw: Tidied probe_names 2012-12-24 13:53:58 +01:00
Uwe Hermann 0aba65da9f ols: Split into api.c and protocol.[ch].
Also, drop various no longer needed #include files.
2012-12-24 13:44:52 +01:00
Uwe Hermann a567547e20 ols: Use logging helper macro. 2012-12-24 13:21:12 +01:00
Bert Vermeulen 11fb7110f4 fluke-dmm: 190 series scopemeter support
199B only for now.
2012-12-24 11:22:01 +01:00
Bert Vermeulen 4cea0ff7fe fluke-dmm: parser cleanup 2012-12-24 11:22:01 +01:00