Remove duplicate sheet instance page numbering. It's already done when
the sheet is loaded from an exiting file or an already loaded schematic.
Remove the unnecessary page update code from the drawing tool.
Ignore bus member connection subgraphs. They do not have a valid net
name nor do they contain schematic items. This prevents empty nodes
from being added to the tree. They can be reintroduced in the future
if someone wants to pursue it.
Freeze the wxTreeCtrl while populating it and thaw when done to prevent
any unnecessary repainting.
Add profiling to test how long it takes to rebuild the net navigator.
The recently added populate the navigator with all nets when no net
is highlighted has exposed some potential performances issues with some
versions of wxWidgets on certain platforms. Namely wxWidgets 3.2.4 on
Linux GTK.
Fix an issue where a sheet name change would not update the highlighted
net navigator resulting in a stale human readable sheet path.
Prevent the highlighted net navigator from being rebuilt twice when
loading a schematic. SCH_EDIT_FRAME::RefreshNetNavigator() was being
called from both SCH_EDIT_FRAME::UpdateHierarchyNavigator() and
SCH_EDIT_FRAME::RecalculateConnectivity().
Add a new trace helper "KICAD_UI_PROFILE" to show trace output when
profiling user interface performance. It's used in the net navigator
profiling mentioned above.
Reuse PROF_TIMER::Show() to generate string for PROF_TIMER::to_string().
Previously, we only allowed pins of the same time as well as passive
pins to be stacked. This change allows NIC pins as well since they are
not internally connected, there is no reason that they cannot be tied to
another pin electrically
C++20 added new reverse and rewritten candidates. This can confuse the compiler because it'll test both A==B and B==A for overloads.
Because we were defining parent class equality overloads, A==B and B==A was considered ambigious due to both being compatible in casting.
So we needed to add explicit child class equality operator overloads
Instances, pins and graphics have started to wander around the files.
Sorts instances before writing. Uses compare with std::set (not
std::multiset) to enfore lib item ordering
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17737
Netclass assignments are stored in the project level but
CONNECTION_GRAPH updates would clear the assignments. This keeps
existing netname->netclass assignments but updates any netnames that
were changed by the incremental updates. Absolute updates are not
affected and fully recreate the net name to netclass map
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17720
We don't neccesarily have a valid pointer to the parent lib symbol when
checking if it is a power symbol, so fall back to the local flag if this
is the case
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17182
(cherry picked from commit 4481fcc75e)
The connectivity routine would consider symbols, overwriting unused
subgraphs for pins that were not in the change list. This is resolved
by updating the full connectivity to only use pins in the graph since
symbols are not connected independently.
In the process of adding QA tests for this change, additional issues
with the schematic QA were discovered. Specifically, we were not
properly setting the root sheet UUID. This was partially masked by a
const_cast setting of the RefDes in sch_symbol when called the RefDes
getter. This exposed the fact that our QA ERC numbers did not match the
schematic editor stand alone ERC numbers. So the test value for one
check needed to be updated
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17528
This will display a better error message to the user, instead of saying
that no plugins to load the file are found (because the plugin tests
will also fail due to being unable to read the file).
Currently, new global or local net labels are auto-filled with the
net name if the wire is driven by a global or local label. This
currently happens recursively within SCH_LINE. This fix moves this
to determining the driver from the connectivity graph, and removes
the determination from the SCH_LINE code where it does not belong.
Prevent the hierarchy navigator from being rebuilt unless there are actual
sheet changes that would cause a change to the tree.
Save the tree expansion state before rebuilding the tree and then restore
the expansion state to the previous state sans edits.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/16635
(Particularly useful for those that have no other settings and
otherwise look blank.)
Also replaces "Generator" terminology as it's a bit confusing
(and will only get more confusing with PCBNew Generators).
Between schematic and pcb editors, we want the following actions:
- Single click on ERC/DRC item should show the item in the ERC/DRC
window. But if the window is not visible, it should only update the
status bar
- Double click on ERC/DRC item should show and raid the ERC/DRC window
as well as select the line item
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17383
If a ERC violation is set to ignore, all corresponding markers are deleted.
But if one of these markers is selected, a crash happens.
Now all selected objects are deselected before deleting markers.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17375
ADDED: Horizontal/vertical zoom for simulator plots, via mouse wheel,
toolbar buttons, menu commands, and hotkeys.
ADDED: Simulator preferences panel, populated with mouse wheel
and trackpad settings that control pan and zoom of simulator plots.
ADDED: Zoom In/Out Horizontally/Vertically commands that can be bound
to hotkeys.
CHANGED: Simulator plot scroll wheel gestures are no longer hard-coded
and can now be configured via the new Simulator preferences panel.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/16597
Other unreported bugs that were fixed:
- Fixed wierd, jumpy simulator plot view limiting behavior.
- Fixed Zoom In Center and Zoom Out Center commands not preserving
the simulator plot center point.
- Fixed simulator plot nudging when exported as PNGs.
- Fixed rectangular selection zoom being able to exceed simulator plot
view limits.
Notes:
- Provided new SIM_PREFERENCES struct to be used for future
simulator preferences set via the simulator preferences dialog.
- Bundled pre-existing EESCHEMA_SETTINGS::SIMULATOR settings into
EESCHEMA_SETTINGS::SIMULATOR::VIEW.
- Replaced mpWindow::EnableMouseWheelPan with more general
SetMouseWheelActions.
- Refactored and tidied up wxMathPlot's mpWindow code involved with
fitting, zooming, and panning.
- Consolidated long lists of duplicated member variable initializers to
a new mpWindow private delegated constructor.
- Provided provisional Zoom In/Out Horizontally/Vertically toolbar
icons that need improvement by a graphics designer.
- Provided gitignore entries for the Qt Creator IDE
Prior to this change, the schematic connectivity was updated any time a
change was made to a connectable object. Now the connectivity is only
updated when an object change actually affects the connectivity. Other
properties like line width, fill type, custom fonts, etc. will not cause
the connectivity graph to be rebuilt.
The SCH_COMMIT flag SKIP_CONNECTIVITY has been removed. All schematic
objects can test if they are connectable and if there have been changes
to any connection properties that require a connectivity rebuild.
Remove duplicate rebuild connectivity calls from editor control tool.
This was causing the tangling end test to get called four times on every
undo and redo action because the dangling end test is already called in
the connectivity graph calculation code.
Update connectivity when changing label names which fixes an unreported
connectivity bug.
Also fixes a wrap-around bug in SPICE_VALUE::Normalize() where
it would lose the run of itself if the value was already
normalized to either the largest or smallest UNIT_PREFIX.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17228
For unique_ptr, release only set the ownership to null, but don't free the resource behind. On the other hand, reset do.
Closes Coverity ID 483269
Closes Coverity ID 471974
Closes Coverity ID 471973
We need at least the root screen in order to handle any action in
Eeschema. Because this is destroyed by starting to load the new
schematic, when failing, we need to reset to null.
This is not as good as resetting to the previous state but that will
take refactoring our file load routines in schematic editor
Fixes https://gitlab.com/kicad/code/kicad/-/issues/16993
Without this, we would parse a legacy schematic symbol field at the same
index as the new description field's index into description, instead of into
a user field.
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/17202
Short description:
Works for Symbol and Footprint Editor behind an advanced config option.
For Symbol Editor it is shown for a single item selection (library or symbol).
For Footprint Editor it is shown for a footprint selection.
(fp editor allows a single tree item selection only).
Option stays hidden if current frame has been modified.
Also small fix(?) for similar action to the project manager.
(Call for the Execution has moved inside the file loop.)
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/15736