Commit Graph

1605 Commits

Author SHA1 Message Date
Uwe Hermann 8852eb75d1 serial-dmm: Drop obsolete extern declaration. 2015-03-21 13:17:51 +01:00
Martin Ling bcbef5ed70 serial-dmm: Declare each meter type in only one place. 2015-03-21 13:13:34 +01:00
Martin Ling 4f840ce965 Pass driver struct pointer to driver callbacks.
This lays the groundwork for subdrivers to share callbacks without
needing a separate wrapper function for each subdriver.
2015-03-21 13:09:40 +01:00
Martin Ling 702f42e8eb rigol-ds: Add DS1000Z series support.
Tested on an MSO1104Z with firmware 00.04.02.SP4.

The analog channels are captured correctly. For the MSO series, with digital
channels, there are two outstanding issues:

1. Logic data is retrieved per-channel, one byte per sample, with the value
   in the LSB of each byte. The current datafeed logic format doesn't allow
   this format to be passed on directly. I suggest we resolve that rather than
   making the driver buffer and interleave the data.

   As stands, the code will retrieve data for all channels and pass it onto
   the datafeed with unitsize=1. Channel D0 can used correctly if selected
   alone. For other channels, data is passed to the frontend but the API does
   not provide a way to associate it with the correct channel.

2. Channels CH3 and CH4 are multiplexed with D0-7 and D8-15 respectively, so
   enabling these is mutually exclusive. We don't currently have a way to
   express this constraint to the frontend.
2015-03-21 01:55:55 +01:00
Uwe Hermann c36f78f772 Add initial Voltcraft VC-870 support.
There are a few details that have yet to be implemented or
reverse engineered and tested.
2015-03-20 21:27:04 +01:00
Bartosz Golaszewski 350b8b07f0 baylibre-acme: Fix a double free in bl_acme_set_shunt().
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
2015-03-20 16:54:02 +01:00
Martin Ling cfcdf57677 scpi-pps: Add profile for Rigol DP821A. 2015-03-20 15:33:49 +01:00
Martin Ling 7d4f1741e3 scpi-pps: Initialise sdi with status SR_ST_INACTIVE.
Without this change a segfault occurs at exit after scan, because
dev_close() is called and the device is believed to be open.
2015-03-20 15:33:49 +01:00
Martin Ling 40c2c9159c rigol-ds: Fix broken channel group check in config_list(). 2015-03-19 23:01:50 +00:00
Martin Ling f579d08bc5 rigol-ds: Data source is a device option, not per channel group. 2015-03-19 23:01:50 +00:00
Martin Ling 98bfc4741f rigol-ds: Use sr_scpi_get_bool(). 2015-03-19 23:01:50 +00:00
Martin Ling bff16ba817 rigol-ds: Fix double free.
std_dev_clear() frees all channel groups, so this one is not required.
2015-03-19 23:01:50 +00:00
Martin Ling 16aca7661b rigol-ds: Fix wrong channel group malloc size. 2015-03-19 23:01:50 +00:00
Martin Ling 5e23fcab88 Simplify channel creation.
We always follow sr_channel_new() with a call to add the channel to the sdi.
Tidy up a bit by adding this functionality to sr_channel_new() instead.
2015-03-19 21:37:33 +00:00
Uwe Hermann bc49777251 fx2lafw: Replace obsoleted strncmp() calls.
The fixed lengths for strncmp() can no longer be used since strings of
various lengths can be passed to match_manuf_prod(). Use strcmp() instead.
2015-03-19 18:25:55 +01:00
eightdot 6fcf3f0a22 Various fixes/updates to make the driver compile.
This patchset was originally done by eightdot <gituser@eightdot.eu> by
manually forward-porting parts of the changes done by Bert Vermeulen (see
previous commits), but then heavily modified by Uwe Hermann to be based on
top off the (git-)rebased patches from Bert Vermeulen instead.

Note: This initial DSLogic code is *not* yet in a working or usable
state. It should be considered as a basis for further work only, for now.
2015-03-19 18:25:55 +01:00
Bert Vermeulen b9d530920f fx2lafw: Basic acquisition support for DSLogic. 2015-03-19 18:25:55 +01:00
Bert Vermeulen a7d7f93c1b fx2lafw: scan/firmware support for DSLogic. 2015-03-19 18:25:55 +01:00
Uwe Hermann f7ab2f231a ols: Fix a compiler warning (unused variable).
CC       src/hardware/openbench-logic-sniffer/api.lo
  ../src/hardware/openbench-logic-sniffer/api.c: In function 'scan':
  ../src/hardware/openbench-logic-sniffer/api.c:103:10: warning: unused
  variable 'probefd' [-Wunused-variable]
    GPollFD probefd;
            ^
2015-03-13 19:12:47 +01:00
Uwe Hermann ed936ccc7c ols: Fix detection and acquisition on Windows.
Use the more portable sp_input_waiting() instead of g_poll() with FDs.
Thanks to Martin Ling for the hints. This is tested on Linux and Win7
using an OLS; scanning for the device and starting an acquisition works.

Also, add some more debug output.

This fixes bug #562.
2015-03-13 18:08:49 +01:00
Bartosz Golaszewski 5fabeeac6a baylibre-acme: correctly handle channel group options
Split device options into general and channel group settings, and
adjust config_list() callback appropriately.

Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
2015-03-11 18:23:41 +01:00
Martin Ling bf622e6d00 Rename SR_CONF_NUM_TIMEBASE to SR_CONF_NUM_HDIV. 2015-03-02 12:24:12 +01:00
Martin Ling f3cde30904 ut372: Initial sub-driver skeleton. 2015-03-01 22:30:57 +00:00
Baruch Even 2cb63065f5 serial-dmm: Add MASTECH MS8250B as a supported DMM.
It is an alias and uses the FS9721 driver.
2015-02-27 15:10:19 +01:00
Uwe Hermann d9c3331d12 asix-sigma: Use the more portable g_usleep(). 2015-02-26 11:15:02 +01:00
Bartosz Golaszewski 380ee96fdf baylibre-acme: don't report ACME as detected if no probes are present
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
2015-02-20 11:22:26 +01:00
Uwe Hermann 3d14ce49e4 baylibre-acme: Fix vendor/device name. 2015-02-17 17:03:41 +01:00
Uwe Hermann d258022db0 baylibre-acme: Drop unneeded comment.
There's indeed no g_fclose() unfortunately. The g_*() wrappers for file
handling are mainly there to deal with portability issues in file names
(encoding, character sets, etc) on different platforms.
2015-02-16 01:57:35 +01:00
Uwe Hermann 3452785431 baylibre-acme: Fix a compiler warning.
Use PRIu64 to avoid the following compiler warning:

    CC       src/hardware/baylibre-acme/gpio.lo
  protocol.c: In function 'bl_acme_set_shunt':
  protocol.c:341:2: warning: format '%llu' expects argument of type 'long long unsigned int', but argument 3 has type 'uint64_t' [-Wformat=]
    g_fprintf(fd, "%llu\n", MOHM_TO_UOHM(shunt));
    ^
2015-02-16 01:57:35 +01:00
Uwe Hermann 391e23a97f baylibre-acme: Minor coding-style, cosmetics. 2015-02-16 01:57:35 +01:00
Bartosz Golaszewski 740ad48ac8 baylibre-acme: Add support for SR_CONF_POWER_OFF.
Allow to remotely cut the power at ACME probe level.

Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
2015-02-16 01:20:08 +01:00
Bartosz Golaszewski 289eebd7ca baylibre-acme: Add Linux-specific GPIO helpers.
These functions allow to export, read and set GPIOs using Linux
sysfs interface.

Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
2015-02-16 01:20:08 +01:00
Bartosz Golaszewski 61f2b7f74c baylibre-acme: Add support for probe factor setting.
Implement support for SR_CONF_PROBE_FACTOR setting in BayLibre ACME
driver. Given the channel-group parameter this allows to set the
shunt resistance for each probe.

Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
2015-02-16 01:20:08 +01:00
Bartosz Golaszewski 6b80b80dcf baylibre-acme: Driver implementation.
Implement basic functionalities for baylibre-acme. Add support
for common config options, device detection and sample reading.

Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
2015-02-16 01:20:07 +01:00
Bartosz Golaszewski dfaee1de17 baylibre-acme: Initial driver skeleton.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
2015-02-16 01:20:07 +01:00
Aurelien Jacobs 96cb7faac3 rigol-ds: fix the smallest supported vdiv for the DS2000 series. 2015-02-15 21:15:27 +01:00
Aurelien Jacobs 81b85663f3 rigol-ds: return the actual hardware num_vdiv and vdiv list. 2015-02-15 21:15:21 +01:00
Aurelien Jacobs c33ff3771b rigol-ds: fix search for the closest vdiv.
We try to find the smallest diff by comparing each diff with
the previously known smallest diff, so initially, this smallest diff
should be INFINITY so that we are sure to find a smaller one.

This fixes the following exception:
sr: rigol-ds: Negative vdiv index: -1.
Caught exception: not applicable
2015-02-15 21:15:04 +01:00
Uwe Hermann f44f7e61a3 rigol-ds: Add missing "break" statements. 2015-02-14 19:32:25 +01:00
Uwe Hermann d50725e012 rigol-ds: Add missing 20/50/100V vdiv entries.
These are available on e.g. Rigol DS1102E (or "upgraded" DS1052E).

Without this, if one of the channels happens to have been set to
one of the missing vdiv settings frontends (e.g. PulseView) will
have some trouble using the scope:

  sr: hwdriver: sr_config_get(): key 30012 (vdiv) sdi 0x11bcb70 cg CH1
  sr: rigol-ds: Negative vdiv index: -1.
  std::exception
2015-02-14 19:32:15 +01:00
Uwe Hermann e1b5b7e735 rigol-ds: Add more debug output. 2015-02-14 18:34:04 +01:00
Aurelien Jacobs d5c4144e2c rigol-ds: handle full word trigger slope in config_get().
Some scope can return POSITIVE/NEGATIVE instead of POS/NEG,
so accept this as well.

This closes bug #558.
2015-02-13 16:37:24 +01:00
Aurelien Jacobs b0c9d1d1c2 rigol-ds: SR_CONF_TRIGGER_SLOPE is actually listable. 2015-02-12 17:58:32 +01:00
Daniel Elstner 57ba5f3d56 sysclk-lwla: Widen constant to 64 bit before shifting
(lwla_convert_trigger): Fix trigger mask computation bug introduced
by recent change:  Widen constant to 64 bit before shifting so that
channel nunmbers beyond 32 are processed correctly.
2015-01-31 21:09:01 +01:00
Bartosz Golaszewski 7a8a1aba37 demo: implement averaging support
Add support for averaging and avg_samples option to the demo device.

Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
2015-01-25 18:00:42 +01:00
Mathias Katzer f62f595bfc hameg-hmo: Fix double-free issue. 2015-01-11 01:43:12 +01:00
Mathias Katzer a1b61e6e04 hameg-hmo: Set SR_CONF_GET | SR_CONF_SET for frame limit.
Reading analog data from an HMO1024 (Firmware 04.527) failed because the
frame limit could not be set.
2015-01-11 01:43:12 +01:00
Bert Vermeulen 974fb0fffa saleae-logic16: Show libusb transfer status name instead of code. 2014-11-28 00:21:56 +01:00
Uwe Hermann a11e10ec91 saleae-logic16: Change two errors into warnings.
Related to #466, convert two more sanity checks from errors into warnings.
This may allow more devices to work with libsigrok.
2014-11-27 23:22:05 +01:00
Bert Vermeulen 5cfcab6603 saleae-logic16: Clearer error message. 2014-11-27 01:01:13 +01:00
Aurelien Jacobs e743a47d6d beaglelogic: Add SR_CONF_CAPTURE_RATIO support. 2014-11-25 22:13:36 +01:00
Aurelien Jacobs 5a971f66a3 saleae-logic16: Add SR_CONF_CAPTURE_RATIO support. 2014-11-25 22:13:36 +01:00
Aurelien Jacobs 7bfcb25cf1 fx2lafw: Add SR_CONF_CAPTURE_RATIO support. 2014-11-25 16:56:34 +01:00
Aurelien Jacobs fe5a735553 soft-trigger: Add support for pre-triggering. 2014-11-25 16:56:34 +01:00
Uwe Hermann b6085eb179 manson-hcs-3xxx: Fix incorrect SR_CONF_SCAN_OPTIONS handling.
The SR_CONF_SCAN_OPTIONS key must be listable with or without sdi,
otherwise the device will not be detected by frontends.
2014-11-23 21:13:16 +01:00
Tim Hatch cd3c4df35a saleae-logic16: Downgrade error during capture to a message.
Some clone doesn't set this to the exact same value, and both bits in 0x48 are
marked as unknown at
http://sigrok.org/wiki/Saleae_Logic16/Firmware#FPGA_variables

This fixes bug #466.
2014-11-23 13:47:45 +01:00
Uwe Hermann 91219afc75 Use g_malloc0() consistently, simplify error handling.
Use g_malloc0() for small allocations and assume they always
succeed. Simplify error handling in a few places accordingly.

Don't always sanity-check parameters for non-public (SR_PRIV)
functions, we require the developers to invoke them correctly.
This allows further error handling simplifications.
2014-11-22 17:02:57 +01:00
Uwe Hermann c368e6f3d2 Don't check sr_channel_new() return value (always succeeds).
We now use g_malloc0() for the allocation and assume the allocation
will always succeed, thus sr_channel_new() will always return a
valid new channel.
2014-11-21 12:10:05 +01:00
Uwe Hermann f57d8ffe66 Consistently use g_malloc0() for allocating devc.
We assume the allocation will always succeed, hence no need for
checking the returned value.
2014-11-21 12:09:01 +01:00
Uwe Hermann aac29cc192 Eliminate sr_dev_inst_new(). 2014-11-21 02:01:36 +01:00
Aurelien Jacobs cf0280fa1b yokogawa-dlm: Publish driver options. 2014-11-19 23:54:01 +01:00
Aurelien Jacobs 413f1944d1 motech-lps-30x: Publish driver options. 2014-11-19 23:53:35 +01:00
Aurelien Jacobs f3ba3c119c manson-hcs-3xxx: Publish driver options. 2014-11-19 23:53:10 +01:00
Aurelien Jacobs 6ec3ef9b92 hameg-hmo: Publish driver options. 2014-11-19 23:52:51 +01:00
Uwe Hermann e07edc83d6 mic-985xx: Correctly report SR_CONF_THERMOMETER/_HYGROMETER.
Some models only log temperature, others log temperature and humidity
(so they need different drvopts).
2014-11-18 23:43:38 +01:00
Uwe Hermann 20a7cd07c9 mic-985xx: Drop unneeded #define. 2014-11-18 23:26:10 +01:00
Uwe Hermann d6e1e6c4e1 mic-985xx: Publish driver options. 2014-11-18 23:26:10 +01:00
Uwe Hermann 489c338884 center-3xx: Drop unneeded #define. 2014-11-18 23:20:09 +01:00
Uwe Hermann 6685e9a6b3 center-3xx: Publish driver options. 2014-11-18 23:20:09 +01:00
Bert Vermeulen 5c868fef43 Revert "victor-dmm: Set spec digits to 3, matching the display."
This reverts commit 28b4243493.
2014-11-18 18:10:19 +01:00
Bert Vermeulen 63ea6141b6 ols: Publish driver options. 2014-11-18 17:41:36 +01:00
Bert Vermeulen f9dada0b60 agilent-dmm: Now really fix driver options. 2014-11-18 17:31:58 +01:00
Bert Vermeulen 42a47a9a4b appa-55ii: Publish driver options. 2014-11-18 16:50:47 +01:00
Bert Vermeulen 5ecd9049e5 hantek-dso: Fix driver options. 2014-11-18 16:46:39 +01:00
Bert Vermeulen 1f889afd61 atten-pps3xxx: Fix driver options. 2014-11-18 16:44:58 +01:00
Bert Vermeulen 023c73ae05 cem-dt-885x: Fix driver options. 2014-11-18 16:44:14 +01:00
Bert Vermeulen 9d9cf1c4b9 scpi-pps: Fix driver options. 2014-11-18 16:44:14 +01:00
Bert Vermeulen 2ff11e50a5 asix-sigma: Fix driver options. 2014-11-18 16:30:47 +01:00
Bert Vermeulen 1e4a7cace2 demo: Fix driver options. 2014-11-18 15:39:46 +01:00
Bert Vermeulen ff6b76a145 fx2lafw: Publish driver options. 2014-11-18 15:35:30 +01:00
Bert Vermeulen ce4bd05256 agilent-dmm: Publish driver options. 2014-11-18 15:34:52 +01:00
Bert Vermeulen 5533392828 victor-dmm: Publish driver options. 2014-11-18 14:34:02 +01:00
Bert Vermeulen 28b4243493 victor-dmm: Set spec digits to 3, matching the display. 2014-11-18 00:24:08 +01:00
Aurelien Jacobs 41caa31909 Add a sr_analog_init() API to initialize sr_datafeed_analog2 struct.
It fills the fields with reasonable default values that should suit
most of the drivers. Drivers are obviously free to override the fields
they want after initializing.
2014-11-17 22:04:24 +01:00
Aurelien Jacobs 62f155f0c7 demo: Fix analog output at low samplerate. 2014-11-17 13:39:53 +01:00
Aurelien Jacobs 3772c04990 demo: Fix square pattern output shorter than other patterns. 2014-11-17 13:39:53 +01:00
Bert Vermeulen 4b664cd6ce demo: Use allocation for model string. 2014-11-14 11:37:11 +01:00
Uwe Hermann 676877f6ce mic-985xx: Convert to use SR_DF_ANALOG2. 2014-11-13 22:51:39 +01:00
Uwe Hermann a84a26d98a victor-dmm: Convert to use SR_DF_ANALOG2. 2014-11-13 22:51:39 +01:00
Uwe Hermann 0af636bed9 Change sr_dev_inst_new() to take no parameters.
Change all callers to set the fields manually as needed.
2014-11-12 17:18:46 +01:00
Uwe Hermann 6508992d04 Brymen BM25x: Drop unneeded _ser/_SER suffix.
There's only one cable for this DMM, thus there's no need for a
_ser/_SER suffix or for specifying the cable name.
2014-11-02 16:40:40 +01:00
Uffe Jakobsen bce75f947d ols: Fix a serial port related issue on FreeBSD.
Add sp_drain() to ensure bytes have actually been transmitted
over the wire.

This fixes bug #414.
2014-11-01 19:44:36 +01:00
Uwe Hermann aab4b8cb70 fx2lafw: Fix wide (16bit) sampling case.
This fixes bug #373.
2014-10-29 22:46:57 +01:00
Bert Vermeulen e3594306a9 zeroplus-logic-cube: Add support for AKIP-9101.
Thanks to Nikita Nazarenko for the patch.
2014-10-29 13:26:57 +01:00
Bert Vermeulen 933defaa03 hantek-dso: Fix driver/global/channel group config keys.
This was way behind and did not yet support channel groups.
2014-10-27 17:09:57 +01:00
Bert Vermeulen e7ba5a994b asix-sigma: Publish driver options. 2014-10-27 17:09:47 +01:00
Bert Vermeulen a258204e00 scpi-pps: Publish driver options. 2014-10-27 17:09:47 +01:00
Bert Vermeulen 390795c099 demo: Rearrange driver and device options. 2014-10-27 17:09:47 +01:00
Bert Vermeulen d7125bfa1e cem-dt-885x: Publish driver options. 2014-10-27 17:09:47 +01:00
Bert Vermeulen d6fa8ace94 atten-pps3xxx: Publish driver options. 2014-10-27 17:09:47 +01:00
Uwe Hermann 8769478c07 Add support for the UNI-T UT71x series (aka Voltcraft VC-920/940/960).
Tested on the Voltcraft VC-920 and VC-940 (both UT-D02 and UT-D04
cables), but it should work for all devices in this series without
any changes.
2014-10-25 17:14:30 +02:00
Bert Vermeulen cf49d66bc6 hantek-dso: Properly zero out MQ flags. 2014-10-22 22:19:41 +02:00
Bert Vermeulen c3eadb0760 scpi-pps: Add support for Fluke/Philips PM2800 series. 2014-10-18 23:21:37 +02:00
Bert Vermeulen c1d56d2013 scpi-pps: Move non-standard data type processing to SCPI parser. 2014-10-18 23:21:37 +02:00
Bert Vermeulen 4a471029c2 scpi-pps: Add channel probe facility to scan.
If the number and specs of the device's channels are not static, i.e.
need to be probed, this facility is needed.

Initially this will be used for the Philips PM2800 series, where only
the model returned by *IDN? is needed. However this could also be used
to do actual discovery with vendor-specific SCPI commands.
2014-10-18 23:21:37 +02:00
Soeren Apel d1314831e4 yokogawa-dlm: Populate sdi->serial_num and sdi->version 2014-10-17 03:02:52 +02:00
Soeren Apel b3fccc851b rigol-ds: Populate sdi->serial_num 2014-10-17 03:02:52 +02:00
Soeren Apel b33db61c48 hameg-hmo: Populate sdi->serial_num 2014-10-17 03:02:52 +02:00
Soeren Apel d08667c53b scpi-pps: Populate sdi->serial_num and fix hw_info mem leak 2014-10-17 03:02:52 +02:00
Soeren Apel 0699ccdd92 sysclk-lwla: Let the sdi getter populate sdi->connection_id
This fixes bug #441.
2014-10-17 03:02:52 +02:00
Soeren Apel c962d07cba ikalogic-scanalogic2: Let the sdi getter popuplage sdi->connection_id
This fixes bug #440.
2014-10-17 03:02:52 +02:00
Bert Vermeulen 984e4b0db8 scpi-pps: Start acquisition on the first enabled channel. 2014-10-17 03:00:55 +02:00
Bert Vermeulen 624503ae90 scpi-pps: Optimize channel selection.
This avoids sending a channel selection command to the device if
the channel we're working on is already on the same underlying
output channel.
2014-10-17 03:00:05 +02:00
Bert Vermeulen ee2860ee11 scpi-pps: Disable beeper during session.
At least the Rigol DP800 series trigger the beeper when changing
channels remotely. Which gets rather annoying when doing acquisition
on three channels as fast as you can.
2014-10-16 15:24:27 +02:00
Bert Vermeulen bf48ccebee scpi-pps: Properly clean up acquisition session. 2014-10-16 14:55:56 +02:00
Bert Vermeulen 60475cd788 scpi-pps: Use only standard SCPI for Rigol DP800 series. 2014-10-16 13:23:21 +02:00
Bert Vermeulen ca95e90fb3 Use SR_CONF_OUTPUT_VOLTAGE_TARGET and _CURRENT_LIMIT.
These describe them better; the two are fundamentally different
things to set.
2014-10-15 12:03:00 +02:00
Bert Vermeulen 53a81803e4 scpi-pps: Split boolean set options into enable/disable.
This makes it easier to support devices that need something else
than "ON" or "OFF".
2014-10-13 12:50:28 +02:00
Janne Huttunen b50891952d Add driver for DER EE DE-5000 LCR meter.
Add a driver for the DER EE DE-5000 LCR meter. This meter is based on
the Cyrustek ES51919/ES51920 chipset and communicates with the host
computer via an optional connectivity kit.

The kit uses an optoisolated unidirectional link to connect to the
meter and an USB cable on the host side. Internally the connection is
using the FTDI FT232R USB UART chip i.e. from the host computer point
of view the meter is connected into an RS-232 serial port.

This driver implements just a thin shim layer for registering the
driver and uses the es51919 module for all the actual work.
2014-10-13 00:56:11 +02:00
Bert Vermeulen f4d3a4fb9a ols: Fix serial port timeout. 2014-10-08 03:00:47 +02:00
Bert Vermeulen 9e6d9bee2a colead-slm: Fix serial port timeout. 2014-10-08 02:23:20 +02:00
Bert Vermeulen 2eb1612d46 atten-pps3xxx: Use serial_timeout(). 2014-10-06 12:12:13 +02:00
Bert Vermeulen 945cfd4fdd atten-pps3xxx: Fix serial port timeout. 2014-10-05 12:29:28 +02:00
Bert Vermeulen 204014007f fluke-dmm: Fix blocking serial write timeout. 2014-10-04 10:39:11 +02:00
Bert Vermeulen 95779b43b8 agilent-dmm: Fix blocking serial write timeout. 2014-10-04 10:39:11 +02:00
Martin Ling eead278242 Add a timeout parameter to blocking serial calls.
Set this new parameter to 0 (no timeout) at every call site. This is
consistent with previous behaviour, so cannot cause any regressions.

Waiting forever for a serial operation is clearly always wrong. Without
specific knowledge of each device and driver however, I can't choose
appropriate timeouts for each call. The maintainers of these drivers
will need to do so, and also add appropriate handling of timeouts.

When this commit is merged, a bug should be entered for each driver
that is touched by it.
2014-10-02 22:06:16 +02:00
Bert Vermeulen 7ce59a3133 Avoid serial_write_blocking() warnings. 2014-10-02 16:01:27 +02:00
Martin Ling 081c214eac Fix similar broken error handling on several serial calls. 2014-10-02 15:57:02 +02:00
Bert Vermeulen 7f22cd9554 kecheng-kc-330b: Fix missing time/frequency weighting. 2014-10-02 15:06:36 +02:00
Bert Vermeulen 8219214ff0 hantek-dso: Code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 15:03:18 +02:00
Bert Vermeulen 385cb66058 demo: Code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 15:02:14 +02:00
Bert Vermeulen f4d0020ec6 fluke-dmm: Code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 15:00:37 +02:00
Bert Vermeulen 65c8d48f14 chronovu-la8: Code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 14:58:57 +02:00
Bert Vermeulen 382cb19f29 asix-sigma: Trigger code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 14:53:20 +02:00
Bert Vermeulen 90486ba835 agilent-dmm: Code cleanup.
This cleans up a warning generated by clang's static analyzer.
2014-10-02 14:11:35 +02:00
Soeren Apel 66c91e2509 Removal of sdi->index, step 8: fix victor-dmm 2014-09-30 01:42:58 +02:00
Soeren Apel bde9fbd197 Removal of sdi->index, step 7: fix testo 2014-09-30 01:42:58 +02:00
Soeren Apel c79d4444fe Removal of sdi->index, step 6: fix sysclk-lwla 2014-09-30 01:42:58 +02:00
Soeren Apel 65340dd5df Removal of sdi->index, step 5: fix ikalogic-scanalogic2 2014-09-30 01:42:58 +02:00
Soeren Apel aed4ad0bea Removal of sdi->index, step 4: fix trivial sr_dev_inst_new() calls 2014-09-30 01:42:58 +02:00
Soeren Apel ce7d3578e3 saleae-logic16: Use physical USB connection instead of sdi->index 2014-09-30 01:42:58 +02:00
Soeren Apel 71580ef1f3 Remove sdi->index from openbench-logic-sniffer and pipistrello-ols 2014-09-30 01:42:58 +02:00
Soeren Apel 395206f460 hantek-dso: Use physical USB connection instead of sdi->index 2014-09-30 01:42:58 +02:00
Soeren Apel ee4f9bb1bd zeroplus-logic-cube: Use physical USB connection instead of sdi->index 2014-09-30 01:42:58 +02:00
Soeren Apel 5e2c86eb31 fx2lafw: Use physical USB connection instead of sdi->index
Previously, sdi->index was used to tell several identical fx2lafw-compatible
devices apart. This was a bit of a hack, so this patch makes it use physical
device connections instead. They're guaranteed to remain the same even if
the USB device reconnects.
2014-09-27 12:49:44 +02:00
Martin Ling 7ef93fb09f tondaj-sl-814: Remove SERIAL_NONBLOCK flag.
All calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:32 +02:00
Martin Ling 539a85596f tondaj-sl-814: Mark serial read/write calls as blocking.
These calls are executed from an event handler and were previously nonblocking,
but they have no partial read/write handling. The code is already marked TODO
for improvement.
2014-09-24 23:30:32 +02:00
Martin Ling 47d98603e7 tondaj-sl-814: Mark serial read call as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. Partial reads are handled.
2014-09-24 23:30:31 +02:00
Martin Ling 9333691aaf teleinfo: Mark serial read as nonblocking, remove SERIAL_NONBLOCK flag.
This call was already nonblocking due to the flag.
2014-09-24 23:30:31 +02:00
Martin Ling 4ded59eef0 openbench-logic-sniffer: Remove SERIAL_NONBLOCK flag.
All calls in this driver are already explicitly (non)blocking.
2014-09-24 23:30:31 +02:00
Martin Ling d12ef776d3 norma-dmm: Remove SERIAL_NONBLOCK flag.
All calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:31 +02:00
Martin Ling 92714255b3 norma-dmm: Make serial write call block.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
2014-09-24 23:30:31 +02:00
Martin Ling 8849f45ad7 norma-dmm: Make write call block.
This call was previously nonblocking, but has no partial write handling.
It is called in the scan where it is free to block.
2014-09-24 23:30:31 +02:00
Martin Ling 32950cc071 norma-dmm: Mark serial read call as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. It only reads one byte, and a zero result is handled
appropriately.
2014-09-24 23:30:31 +02:00
Martin Ling 5b980134c5 motech-lps-30x: Remove SERIAL_NONBLOCK.
All calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:31 +02:00
Martin Ling 856dccb7a6 motech-lps-30x: Make serial write call block.
This call was previously explicitly nonblocking, but has no partial write
handling. It sends a short packet so should be OK to block, most likely the
output buffer will be empty anyway.
2014-09-24 23:30:31 +02:00
Martin Ling e050124095 motech-lps-30x: Mark serial read call as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. It only reads one byte, and a zero result is handled
appropriately.
2014-09-24 23:30:31 +02:00
Martin Ling 51056d61ec mic-985xx: Remove SERIAL_NONBLOCK call.
All calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:31 +02:00
Martin Ling 3e2373247c mic-985xx: Make serial write call block.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
2014-09-24 23:30:31 +02:00
Martin Ling 98842e53eb mic-985xx: Mark serial read as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. Partial reads are handled.
2014-09-24 23:30:31 +02:00
Martin Ling e13e354f89 gmc-mh-1x-2x: Remove SERIAL_NONBLOCK flag.
All calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:31 +02:00
Martin Ling 612db3c44b gmc-mh-1x-2x: Make serial write calls block.
These calls are executed from an event handler and were previously nonblocking,
but have no partial write handling. They send short packets so should be OK to
block, most likely the output buffer will be empty anyway.

Fix error handling for some: serial_write can return any negative error code.
2014-09-24 23:30:30 +02:00
Martin Ling e1960467ce gmc-mh-1x-2x: Make serial write call block, and fix error handling.
This call was previously nonblocking, but there is no handling of partial
writes. It is called from config_set where it is free to block.

Also fix error handling: serial_write can return any negative error code,
not just -1.
2014-09-24 23:30:30 +02:00
Martin Ling 4a0eda2b70 gmc-mh-1x-2x: Mark serial read calls as nonblocking.
These calls were already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. They only read one byte. A return value of zero is not
handled, but should not occur in theory due to the G_IO_IN check. It might be
good to add handling of a zero return anyway, since I'm not sure if this is
always accurate.
2014-09-24 23:30:30 +02:00
Martin Ling 0714a010cc gmc-mh-1x-2x: Mark serial read call as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. It only reads one byte, and a zero result is handled
appropriately.
2014-09-24 23:30:30 +02:00
Martin Ling bb27c76513 fluke-dmm: Make serial write calls block, and fix error handling.
These calls are executed from an event handler and were previously nonblocking,
but have no partial write handling. They send short packets so should be OK to
block, most likely the output buffer will be empty anyway.

Also fix error handling for these calls, which seems to have been retained from
previous direct usage of write() to a serial port fd.
2014-09-24 23:30:30 +02:00
Martin Ling 50276118ca fluke-dmm: Make serial write calls block, and fix error handling.
These calls were previously nonblocking, but have no partial write handling.
They are made from scan and acquisition_start contexts where they are free
to block.

Remove the SERIAL_NONBLOCK at open, which only applied during scan, since all
calls in the scan are now explicitly blocking.

Also fix error handling for these calls, which appears to have been kept
from a previous direct usage of write() on a serial port fd.
2014-09-24 23:30:30 +02:00
Martin Ling 707fa85ad5 fluke-dmm: Mark serial read call as nonblocking.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. Only one byte is read. The case of 0 being returned
is not handled, but the call is only made if G_IO_IN occurred so in theory,
there should be a byte available. It might be wise to add handling for a
return of 0 nonetheless, as I'm not sure if this is always accurate.
2014-09-24 23:30:23 +02:00
Martin Ling 55e32714f9 conrad-digi-35-cpu: Make serial write call block.
This call was previously nonblocking, but there is no partial write handling.
It is only called from config_set so it is free to block.
2014-09-24 23:30:01 +02:00
Martin Ling 0ac161bba0 conrad-digi-35-cpu: Remove SERIAL_NONBLOCK flag from open at scan time.
This open call is only made to check access, the port is closed immediately
afterwards. The flag therefore has no effect.
2014-09-24 23:30:01 +02:00
Martin Ling c9fc06d7f0 colead-slm: Mark serial read calls as nonblocking.
This is an odd one. These calls are made from a receive handler so should not
block, and appear to be setup correctly to handle partial reads or no data
available. However, the driver was not opening the port with SERIAL_NONBLOCK
so these calls would have been blocking. Make them nonblocking.
2014-09-24 23:30:01 +02:00
Martin Ling 258a23134d center-3xx: Remove SERIAL_NONBLOCK flag.
All serial calls in this driver are now explicitly (non)blocking.
2014-09-24 23:30:00 +02:00
Martin Ling c1da74fc0a center-3xx: Make serial write call block.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
2014-09-24 23:30:00 +02:00
Martin Ling 3582ce8a01 center-3xx: Mark serial read call as nonblocking.
This call was already nonblocking because the driver opens the port with the
SERIAL_NONBLOCK flag. Partial reads are handled.
2014-09-24 23:30:00 +02:00
Martin Ling d7b269da8f cem-dt-885x: Mark serial access as nonblocking, remove SERIAL_NONBLOCK flag.
These calls were already nonblocking since this driver opened the port with
the SERIAL_NONBLOCK flag. Having marked them as such, we can remove the flag.

Also remove an unnecessary reopen of the port to change its blocking status.
2014-09-24 23:30:00 +02:00
Martin Ling ca4266a02f brymen-dmm: Remove SERIAL_NONBLOCK flag.
All serial read/write calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:00 +02:00
Martin Ling 776313d997 brymen-dmm: Make serial write call block.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
2014-09-24 23:30:00 +02:00
Martin Ling 44be13b1f8 brymen-dmm: Mark serial read calls as nonblocking.
The driver opens the port with SERIAL_NONBLOCK so these were already
nonblocking, and are handled appropriately.
2014-09-24 23:30:00 +02:00
Martin Ling 5305266a28 atten-pps3xxx: Remove SERIAL_NONBLOCK.
All serial read/write calls in the driver are now explicitly (non)blocking.
2014-09-24 23:30:00 +02:00
Martin Ling c3116bc311 atten-pps3xxx: Make serial write call block.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
2014-09-24 23:30:00 +02:00
Martin Ling e7b4103697 atten-pps3xxx: Make serial write call block in scan.
This is called at scan time so free to block. There is no partial write
handling and a response is expected afterwards. This should therefore be a
blocking call.
2014-09-24 23:30:00 +02:00
Martin Ling 25dd083128 appa-55ii: Mark serial read nonblocking and remove SERIAL_NONBLOCK.
This is the only read/write call in the driver. It is already non-blocking
and is handled appropriately.
2014-09-24 23:29:49 +02:00
Martin Ling 64c536be52 aglient-dmm: Remove SERIAL_NONBLOCK flag.
All serial calls in this driver are now explicitly (non)blocking.
2014-09-24 23:18:21 +02:00
Martin Ling a5053ddd21 agilent-dmm: Make serial write call block in send.
This call is executed from an event handler context was previously
nonblocking, however there is no handling for a partial write.

The output buffer is unlikely to be full and the commands to be sent
are short, so it should be OK to make this a blocking call.
2014-09-24 23:18:21 +02:00
Martin Ling 485b9ae34d agilent-dmm: Make serial write call block in scan.
This call is executed at scan time so is free to block. There is no
handling for a partial write and a response is expected immediately
afterwards. It should therefore be a blocking call.
2014-09-24 23:18:21 +02:00
Martin Ling e0b781a45b agilent-dmm: Mark serial read call as nonblocking.
This driver opens the port with the SERIAL_NONBLOCK flag, so this call is
already a nonblocking one, and is handled appropriately.
2014-09-24 23:18:21 +02:00
Martin Ling 2e360339f9 serial-dmm: Remove SERIAL_NONBLOCK flag.
All serial read/write calls in this driver are now explicitly
nonblocking so there is no need for this flag.
2014-09-24 23:18:20 +02:00
Martin Ling 4277ac349c serial-dmm: Mark serial read/write calls as nonblocking.
This driver opens the port with the SERIAL_NONBLOCK flag so these calls were
already non-blocking.
2014-09-24 23:18:20 +02:00
Martin Ling 02bd1d0298 colead-slm: Mark serial write call as blocking.
This driver opens the port without the SERIAL_NONBLOCK flag,
so this call was already blocking.
2014-09-24 23:18:20 +02:00
Martin Ling bbff0fe0d2 manson-hcs-3xxx: Mark serial read call as blocking.
This driver opens the port without the SERIAL_NONBLOCK flag, so this call is
already a blocking one.
2014-09-24 23:18:20 +02:00
Bert Vermeulen f12d997948 demo: Fix pattern mode and amplitude option publishing. 2014-09-23 22:40:47 +02:00
Bert Vermeulen 9a10ce65d6 colead-slm: Properly check acquisition sample limit. 2014-09-23 22:27:34 +02:00
Uwe Hermann af945a6625 Typos and consistency fixes. 2014-09-19 01:03:32 +02:00
Bert Vermeulen d4ccb6bd8f yokogawa-dlm: Don't implement dummy scan options. 2014-09-17 17:41:41 +02:00
Bert Vermeulen 5827f61b64 Publish config key capabilities.
Every driver now publishes its device option config keys, i.e. the
list fetched with sr_config_list(SR_CONF_DEVICE_OPTIONS), with a
set of flags indicating which methods are implemented by the driver
for that key.

The config keys are OR'ed with any combination of SR_CONF_GET,
SR_CONF_SET and SR_CONF_LIST. These are defined as the high bits
of the uint32_t config key. Clients can OR config keys with
SR_CONF_MASK to strip out these bits. This mask will be kept up to
date if other bits are added to the capabilities list; clients MUST
therefore use SR_CONF_MASK for this.

Some keys don't have capability bits added, such as the informative
device type keys (SR_CONF_MULTIMETER, SR_CONF_OSCILLOSCOPE, ...) and
SR_CONF_CONTINUOUS.

Scan options do not have capabilities bits.
2014-09-17 15:36:11 +02:00
Bert Vermeulen 138589b02e beaglelogic: Add missing scan options, and cleanup. 2014-09-16 23:51:38 +02:00
Bert Vermeulen a0e0bb4149 Consistently use 'scanopts' variable across all drivers. 2014-09-16 22:19:02 +02:00
Bert Vermeulen f254bc4bba Consistently use 'devopts' variable across all drivers. 2014-09-16 22:11:39 +02:00
Bert Vermeulen 584560f142 Change type of SR_CONF keys to uint32_t. 2014-09-16 21:22:41 +02:00
Bert Vermeulen bfc8679937 scpi-pps: Clean up HP 6632B profile. 2014-09-09 13:24:30 +02:00
Bert Vermeulen 331f56543a scpi-pps: Fix compile warning. 2014-09-08 23:31:54 +02:00
Bert Vermeulen fdedbfcdef scpi-pps: Fix config_set checks. 2014-09-08 23:30:21 +02:00
Aurelien Jacobs effb9dd1c2 rigol-ds: replace some magic numbers by appropriate constant or variable
This fixes bug #406.
2014-09-08 12:58:30 +02:00
Bert Vermeulen bc4a2a46ed Add support for HP 6632B. 2014-09-08 12:45:21 +02:00
Bert Vermeulen 01b0257aef scpi-pps: Create one channel per MQ/output combination.
This allows frontends to trivially select which MQs on which channels
they want to see; others won't even be fetched.
2014-09-08 12:45:21 +02:00
Bert Vermeulen 478c8d923e scpi-pps: Simplify SCPI command handling. 2014-09-08 12:45:21 +02:00
Bert Vermeulen 3222ee103d scpi-pps: Add support for Rigol DP831A/DP832A. 2014-09-08 12:45:21 +02:00
Bert Vermeulen 58b77c41ff scpi-pps: Use regex to match model names. 2014-09-08 12:45:21 +02:00
Bert Vermeulen 22c18b0370 scpi-pps: Generalize vendor name cleanup. 2014-09-08 12:45:21 +02:00
Bert Vermeulen d4eabea847 scpi-pps: Add support for Rigol DP832. 2014-09-08 12:45:21 +02:00
Bert Vermeulen 9e45cd41fd scpi-pps: Add basic cross-vendor PPS functionality. 2014-09-08 12:45:21 +02:00
Bert Vermeulen a1eaa9e066 Revamp PPS-related config keys. 2014-09-08 12:45:21 +02:00
Bert Vermeulen ca1a7cb56f scpi-pps: Initial driver skeleton. 2014-09-08 12:45:21 +02:00
Aurelien Jacobs af1e487e3f brymen-bm86x: Add current loop sensor support. 2014-09-06 17:22:03 +02:00
Bert Vermeulen 110fe1b4a2 agilent-dmm: U124xx/U125xx: Add current loop sensor support.
Also fixes frequency support.
2014-09-02 21:55:52 +02:00
Bert Vermeulen c7f5219e62 agilent-dmm: Add temperature regex to U125xx parser. 2014-09-02 01:01:56 +02:00
Bert Vermeulen a965748ae2 agilent-dmm: U124xx/U125xx: support 5 more modes.
This adds support for resistance, capacitance, frequency, continuity,
and temperature.
2014-09-02 00:55:41 +02:00
Matthias Heidbrink 5791bdf604 gmc-mh-1x-2x-rs232: Completed energy measurement ranges (V, A, W) for Metrahit 29S. 2014-09-01 23:14:56 +02:00
Bert Vermeulen ee2bcdfc44 agilent-dmm: U124x/U125x fixes. 2014-09-01 21:44:37 +02:00
Soeren Apel ac10a927b5 yokogawa-dlm: Replace g_try_malloc() calls and fix coding style 2014-08-31 00:42:10 +02:00
Soeren Apel 0028d5a1ee yokogawa-dlm: Lower timeout to increase throughput and fix data acq bug 2014-08-31 00:42:10 +02:00
Soeren Apel af3487ec28 yokogawa-dlm: Do not block when receiving and save frame length in scope state 2014-08-31 00:42:10 +02:00
Soeren Apel 8ab929d614 yokogawa-dlm: Flesh out driver with current state of development 2014-08-31 00:42:10 +02:00
Soeren Apel 107639373d yokogawa-dlm: Integrate driver skeleton 2014-08-31 00:42:10 +02:00
Bert Vermeulen 4edba404b0 agilent-dmm: Add U124xx device IDs. 2014-08-30 19:32:15 +02:00
Bert Vermeulen 173378f0f5 agilent-dmm: Add provisional support for the U124xx. 2014-08-29 23:42:06 +02:00
Bert Vermeulen f857bd928d agilent-dmm: Assume all A and B models are identical on the wire. 2014-08-29 23:42:06 +02:00
Bert Vermeulen 51b92b7da4 agilent-dmm: Add RMS flag to AC voltage modes. 2014-08-29 23:42:06 +02:00
Bert Vermeulen f216eb8699 agilent-dmm: Correctly parse negative overload. 2014-08-29 23:42:06 +02:00
Uwe Hermann e6284bf09f Remove unneeded subdriver debug messages. 2014-08-29 23:02:22 +02:00
Bert Vermeulen 7c03b56443 agilent-dmm: Fix value parser.
This considered 0.0 to be an invalid result for no good reason.
2014-08-28 17:44:24 +02:00
Peter Zotov 6f479a0a72 Add support for mcupro Logic16, a Saleae Logic16 clone.
From sigrok's point of view, this analyzer has two differences:

  * It does not require uploading the firmware.
  * It returns garbage in some registers used for sanity checks.
    Saleae's software ignores that garbage; sigrok only does if it
    specifically detects the mcupro clone.
2014-08-28 14:03:21 +02:00
Bert Vermeulen 81a3497655 fx2lafw: Code cleanup. 2014-08-26 01:49:00 +02:00
Bert Vermeulen 84cbaf77b4 pipistrello-ols: Disable unused trigger stages.
Thanks to Magnus Karlsson for this fix.
2014-08-25 01:00:55 +02:00
Bert Vermeulen acc885c755 pipistrello-ols: Preliminary port to current API. 2014-08-25 01:00:55 +02:00
magnuskarlsson b94cff407f DEMUX and RLE fixes 2014-08-25 01:00:55 +02:00
magnuskarlsson 1e0de84608 added edge triggers 2014-08-25 01:00:55 +02:00
magnuskarlsson 1f9bcd0f94 fixed typos 2014-08-25 01:00:55 +02:00
magnuskarlsson 72716f15be fixed a problem with USB defines 2014-08-25 01:00:55 +02:00
magnuskarlsson 4bd80e1228 added pipistrello-ols
Conflicts:
	configure.ac
	src/hwdriver.c
2014-08-25 01:00:55 +02:00
Soeren Apel 562b7ae513 hameg-hmo / rigol-ds: Restore compatibility with std_dev_clear() 2014-08-24 16:54:38 +02:00
Martin Ling 14e1aa6df0 rigol-ds: Fix duplicated vendor string for Agilent devices. 2014-08-22 20:15:32 +01:00
Marc Schink f817f05aac ikalogic-scanaplus: Free device context to fix memory leak.
Best regards,
Marc

>From 779ef3a1150b3679ab357ceb0e2f50785ad90d28 Mon Sep 17 00:00:00 2001
From: Marc Schink <sigrok-dev@marcschink.de>
Date: Wed, 20 Aug 2014 05:42:07 -0400
Subject: [PATCH] ikalogic-scanaplus: Free device context to fix memory leak.
2014-08-20 14:20:55 +02:00
Marcus Comstedt 7754fb4d93 saleae-logic16: Recognize FPGA FIFO overflow status 2014-08-17 16:24:14 +02:00
Soeren Apel db81fbb582 hameg-hmo: Make sure the enabled_channels list is empty before populating it
Previous runs of dev_acquisition_start() keep the enabled_channels list
populated if they fail. This means that once an invalid channel
configuration was detected, it will be detected again even if the channel
configuration was changed. With this change, the list will be cleared
before being populated so that any stale entries are removed.
2014-08-14 22:43:57 +02:00
Soeren Apel b4e31d2aac Fix typo in the Hameg HMO driver and add some error message for when the float comparison breaks 2014-08-08 17:12:58 +02:00
Bert Vermeulen 226363c4e8 hameg-hmo: Implement SR_CONF_SCAN_OPTIONS. 2014-08-03 14:00:07 +02:00
Janne Huttunen a24c3f4a89 Implement Brymen BM25x series as a serial DMM.
The Brymen BM25x series supports the BC-20X that is an opto-isolated
serial cable. The link seems to be unidirectional i.e. when activated
the DMM periodically sends updates to the host while the host cannot
control the DMM in any way.

The protocol is documented in "6000-count-digital-multimeters-r1.pdf"
that is available from the manufacturer. Every 15 byte packet consists
of a bitmap where the bits correspond to segments or symbols on the
LCD display i.e. the DMM essentially sends the contents of its screen
to the host in every update. This driver then decodes the measured
quantity, unit and its value from the bitmap.
2014-08-01 20:31:26 +02:00
Bert Vermeulen 49224c2853 demo: Attach analog generator to channel, not channel group.
This also adds a new channel group "Analog", which has all analog
channels in it.
2014-07-29 02:00:57 +02:00
Bert Vermeulen dddabe3705 demo: Support changing the amplitude of analog channels. 2014-07-28 15:40:26 +02:00
Bert Vermeulen ed0b7fed10 demo: Free analog channel groups when done with them.
This fixes a memory leak.
2014-07-24 21:01:39 +02:00
Bert Vermeulen 4d7b36a0b5 fx2lafw: Check for valid samplerate before setting. 2014-07-23 12:32:35 +02:00
Bert Vermeulen b62bb97afb demo: Support continuous acquisition. 2014-07-23 04:53:25 +02:00
Bert Vermeulen 2f663c826a fx2lafw: Fix continuous mode. 2014-07-23 00:24:39 +02:00
Bert Vermeulen 155b680da4 Reorganize project tree. 2014-07-22 18:19:29 +02:00