According to the latest available version of the manual, as
for the RTB2000 and RTM3000 series, the RTA4000 series also
uses a slightly different dialect than other previously
supported models, in particular when it comes to the POD
(logic channel groups) handling.
I do not have such model available for testing therefore, as
for the RTB2000 and RTM3000 support recently introduced, I do
not know whether or not the RTA4000 also understands the
existing dialect. In doubt, the new official dialect is
implemented by this patch.
According to the latest available version of the manual, they
both use a slightly different dialect than currently supported
models, in particular when it comes to the POD (logic channel
groups) handling.
I do not have any of the above models available for testing
therefore I do not know whether or not they also understand
the existing dialect. In doubt, the new official dialect is
implemented by this patch.
Update the oscilloscope state with new settings only after
they have been successfully stored in the device to avoid
an inconsistent state in case of SCPI SET command failure.
The hameg-hmo driver returns an incorrect sample rate: to reproduce this
bug, set the maximum sample rate from the ACQUIRE menu.
This patch fixes the driver so that the correct sample rate is returned.
During the initial configuration phase of the hameg-hmo driver
only send an OPC command if a SCPI command has been previously
sent to the device so that bogus SCPI timeouts are avoided.
The current starting index for the POD name is currently wrong as it is zero.
The official POD numbering starts instead at 1 (see device panel, buttons
and manual), so the current index used for message printing and groups
naming in the driver needs to be incremented by one.
Avoid double memory freeing leading to segmentation fault in when a SCPI
command fails to get a string due conditions such as a timeout or an invalid
command.
When setting the type of slope for the edge trigger function, also set the
trigger type to edge because it is not necessarily configured that way and
therefore such functionality might fail to work properly!
This fixes parts of bug #1328.
Update the Hameg/Rohde&Schwarz HMO driver (hameg-hmo) so that it
is possible to configure the logic threshold for digital signals.
The user can get or set the logic threshold configuration using
the channel group POD0 (and/or POD1 where available), for example:
sigrok-cli --driver hameg-hmo --get logic_threshold -g POD0
sigrok-cli --driver hameg-hmo --config logic_threshold=TTL --set -g POD0
sigrok-cli --driver hameg-hmo --get logic_threshold_custom -g POD0
sigrok-cli --driver hameg-hmo --config logic_threshold_custom=0.7 --set -g POD0
Update the default serial port options for Rohde&Schwarz and
Hameg mixed-signal oscilloscope devices connected through USB.
Also, remove misplaced and unused serial port configuration option.
This patch complements fa3d104f17
in terms of updating the USB PIDs for new devices (HMO series).
This fixes parts of bug #1321.
At the moment only the maximum number of frames to be acquired can be
configured for the Hameg/Rohde&Schwarz HMO mixed-signal oscilloscope
series driver (hameg-hmo).
This patch adds support to configure the number of samples to acquire
in both analog and digital (logic) mode.
This patch introduces the support for 16 digital (logic) channels for the
following oscilloscope models: HMO3032, HMO3042, HMO3052 and HMO3522
(previously only 8 digital channels were supported, i.e. only 1 POD).
This patch takes care of removing an invalid product model (HMO2522)
and adds a missing product model (HMO3522) in the hameg-hmo driver,
thus extending the number of supported oscilloscope models.
This fixes bug #1322.
The trigger range/mask "compression" procedure is apparently not
required and breaks triggering on a low line state.
This has been verified to fix the issue on a Hantek 4032L with FPGA
version 0x4303. It is possible that the procedure mentioned above
might be required for other FPGA versions, though that is unknown.
If you experience trigger issues with other FPGA versions, please
contact us for further debugging and testing.
This fixes bug #1402.
Some meters require the reception of a request before they provide
acquisition data. Add support for the chip driver's .packet_request()
routine, and timeout handling in the serial-lcr driver. This follows
the serial-dmm model.
Allow LCR chip drivers to specify custom printf() formats for their
channel names. Default to "P1" etc in the absence of format specs.
This implementation is similar to serial-dmm.
Bug #1390 reports that "!desc" is always true (should be: false?). But
the actual problem would be that 'desc' is _not_ NULL when none of the
supported chips' VID:PID matched (FT232H happens to "get found" then,
erroneously).
Add a sentinel to the table of supported chips, such that 'desc' becomes
NULL upon mismatch, and the error path is entered.
The serial-dmm entry for Victor DMMs is able to communicate to either
geniune COM ports (RS232 or USB CDC) or the obfuscating USB HID cables.
The victor-dmm driver became obsolete and was removed. Rename the
serial-dmm entry, remove the no longer needed "-ser" suffix. Suggest a
default connection via the obfuscating USB HID cable, accept user
provided overrides for regular serial cables (same behaviour as before,
connection spec for serial ports keeps being mandatory).
Remove the victor-dmm device driver. Its functionality is contained in
the Victor specific serial-over-HID transport, the FS9922 DMM parser,
and the serial-dmm device driver. The additional implementation became
obsolete.
This undoes the essence of commit bf700f679a, which introduced the
default conn= spec. Which improved usability: Users just select the
device and need not specify the connection. But also resulted in the
UT32x thermometer driver's probe to "succeed" as soon as the WCH CH9325
chip was found, no data check was involved in the scan. Unfortunately
this chip is also used in the popular UT-D04 cable, and thus there were
many false positives.
Remove the src/hardware/brymen-bm86x/ hierarchy of source files. Its
functionality has moved to the bm86x packet parser and the serial-dmm
device driver.
Request packets from the Brymen BM86x meter much faster. The previous
implementation in the separate driver used to immediately send another
request when a measurement arrived, with a 10ms granularity in the poll
routine, and a 500ms timeout between requests.
Considering the meter's update rate, stick with the 500ms timeout, but
increase the maximum request rate to 10 per second, with a minimum of 2
per second. This receives measurement data at the meter's capability
(compare DC and AC modes, seems to automatically adjust to the internal
operation, and match the display update rate).
Move Brymen BM86x specific packet parse logic to a new src/dmm/bm86x.c
source file, and register the routines with the serial-dmm driver's list
of supported devices. Which obsoletes the src/hardware/brymen-bm86x/
hierarchy.
This implementation differs from the previous version: The parse routine
gets called multiple times after one DMM packet was received. Values for
the displays get extracted in separate invocations, the received packet
is considered read-only. Unsupported LCD segment combinations for digits
get logged. Low battery gets logged with higher severity -- the validity
of measurement values is uncertain after all. The parse routine uses
longer identifiers. Packet reception uses whichever serial transport is
available (need no longer be strictly USB HID nor libusb based). All
features of the previous implementation are believed to still be present
in this version.
This configuration queries measurement values each 0.5 seconds and
re-sends a not responded to request after 1.5 seconds. Which follows the
combination of the vendor's suggested flow (frequency) and the previous
implementation's timeout (3x 500ms). This implementation does not try to
re-connect to the HID device for each measurement, and neither checks
for the 4.0 seconds timeout (vendor's suggested flow). Local experiments
work without these.
The src/hardware/brymen-bm86x/ source code contains specific support for
the Brymen BM86x devices, and directly depends on the libusb library.
Rename the registered device (append the "-usb" suffix) before adding
BM86x support to the serial-dmm driver.
Some meters which are supported by the serial-dmm driver don't strictly
require the user's COM port specification. When a known (usually bundled,
or even builtin) cable type is used, we can provide a default conn= spec
and thus improve usability. Prepare the DMM_CONN() macro, accept user
overrides.
The 'conn' field in the device context and the CONN values in the
declarations of supported DMM models seemed inappropriate. They specify
the communication parameters (UART frame format and bitrate), not the
connection (port name). Adjust the respective identifiers.
Also rephrase the evaluation logic. Instead of checking for the absence
of user specs and optionally assigning a fallback value, just preset
from defaults and override from user specs when present. This simplifies
the logic (eliminates a check).
Keep the ES51919 chip support in the src/lcr/ directory, and move device
driver specific code to the src/hardware/serial-lcr/ directory. Implement
the same driver layout for LCR meters as is used for DMM devices.
This also addresses a few issues in the serial-lcr driver: Unbreak --get
and --show, do process a few LCR packets after probing the device, to
gather current parameter values. Keep sending meta packets when these
parameters change during acquisition, like the previous implementation
did. Use common code for frame/time limits.
Note that although LCR meters usually operate with AC to classify L/C/R
components, one of the officially supported modes is DC resistance.
Which means that an output frequency of 0 is not just a fallback when
packet parsing fails, it's also a regular value of the freq parameter.
List all supported frequencies including DC in strict numerical order.
Although all currently supported devices use the same ES51919 chip, the
implementation is prepared to support other devices which use different
LCR meter chips as well. The list of known equivalent circuit models and
output frequencies is kept in src/lcr/ chip support. It's assumed that
one LCR packet communicates the data for all channels/displays similar
to the serial-dmm driver implementation.
The serial communication timing parameters during probe get determined
from earlier serial port configuration, which obsoletes the redundant
'baudrate' parameter, and eliminates potential inconsistency between
user specified parameters and builtin default values.
The serial communication timing parameters during probe get determined
from earlier serial port configuration, which obsoletes the redundant
'baudrate' parameter, and eliminates potential inconsistency between
user specified parameters and builtin default values.
The serial_stream_detect() routine needs to estimate the time which is
needed to communicate a given amount of data. Since the serial port got
opened and configured before, the serial communication parameters are
known, and callers need not redundantly specify the bit rate.
Register another driver for the UNI-T UT612 LCR meter, which is based on the
ES51919/ES51920 chipset, too. This device had been usable before when the
internal UART connection was made accessible (read: with a hack). It became
officially supported in unmodified form with the addition of transparent
serial over HID support for SiLabs CP2110 chips.
Switch the UT32x driver from running specific USB transfers to generic
serial communication. Preset the bitrate and frame format, but allow for
user specified overrides as well. Default to the WCH CH9325 HID chip,
but allow for overrides or more specific selection so that users can
resolve ambiguities with multiple cables.
The switch from libusb to hidapi removes a limitation that specifically
was reported for the Mac platform. The serial-over-HID variant should
now work as well. See bug #555.
Drop the background transfers. Stick with a local acquisition stop
routine, because a STOP request needs to get sent to the device. Reduce
the receive buffer size such that either blocking or non-blocking calls
will work. The additional flexibility of the buffer handling and packet
processing does not harm.
Eliminate a direct libserialport dependency in the OLS device driver.
Use libsigrok's internal serial layer's API instead to check for the
availability of receive data.
The rohde-schwarz-sme-0x device driver used to unconditionally reference
a libserialport header file. Remove that reference, it's not needed in
this specific driver.
Don't exit with an error if the FPGA is detected as unsupported.
Just issue a warning with the detected version and continue. I have such
a clone and it works with the original Saleae software and with sigrok
despite the fact that its FPGA version is 0xff.
Their commands are very similar to the U123x series, they just
add some more modes and the second channel. So use the re-functions
and just extend them where necessary.
Log reading not supported yet.
Basic testing done with a U1272A.
- fix the resolution of the CONF?-response:
the resolution is given with 6 decimal places
(instead of 8) like this:
VOLT +5.000000E+00,+1.000000E-04
- add more measurement modes that are possible with the meter:
CONT,COND,TEMP,PULS
src/hardware/sysclk-sla5032/protocol.c: In function ‘la_start_acquisition’:
src/hardware/sysclk-sla5032/protocol.c:244:8: warning: implicit declaration of function ‘max’ [-Wimplicit-function-declaration]
pre = max(pre, 2);
^~~
Without a measured quantity in packet.meaning->mq the C++ binding function
sigrok::Analog::mq() throws an exception and there is no way to check if
there is any measured quantity set in the analog package.
Add support for the Pepino-style of accessing >256K of memory. Because
this the only known extension of accessing >256K currently, we apply it
as soon as the sample size is bigger than 256K. Let's hope other
devices (if any) will follow this style. If not, we need to add support
depending on the device name later.
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
Magnus (creator of the Pipistrello) confirmed that he mixed up the
register names. The code was doing it correctly nonetheless but was
confusing to read because of this. Fix it to make it easier to
comprehend.
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
Let max_channels really carry the number of maximum channels the
hardware supports. We will handle the limitation of only half the
channels available in 200MHz mode later. Note that there won't be a
regression because we only set the variable but never check it. The
desired result of this patch is the removal of the NUM_CHANNELS macro.
The number of channels needs to be dealt with at runtime.
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
We needs this twice so put it into a seperate function, so updates to it
will automatically handled for both callers.
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
commit f51acd69 ("ols: combine demux samples") wrongly replaced the bit
pattern of 0x20 with the number of channels which just happens to be 32
as well. So, the code works but is confusing to read. Reword the
for-loop to make it more comprehensible.
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
The OLS protocol sends 16bit values to specify the sample count and
delay count. However, this 16bit value is the number of 32bit words to
be sampled, so the actual sample count is 4 times larger and does not
fit into a uint16_t. Extend it to support the full range of 256K
(LogicShrimp will need this) and to prepare support for devices with
even more memory (Pepino).
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
The previous implementation assumed that a receive data chunk ends
exactly with a sensor packet's end. Yet the buffer had 32 bytes while
the packets have 19 bytes.
Separate the data reception from the packet processing. Collect whatever
chunks the USB connection provides, and scan the resulting buffer for
packets. Cope with either incomplete or corrupt or misaligned packets as
well as with multiple packets in receive chunks. The latter might happen
upon initial synchronization, when a device already sends data or the
serial port buffered previously communicated data.
In the regular case, the computer will process so fast that each single
character will be handled individually. We don't mind. The frequency is
some 60 times per second, and the data volume is 19 bytes. The software
works for the regular case, and synchronizes fast at startup or after
comm errors.
Always print the data bytes of received buffers in the packet parser,
then check some more fixed fields to not process invalid packets, then
process the packet content as the previous implementation did.
Call the packet parser for incomplete packets and discarded input
buffers as well (initial synchronization, re-sync after comm errors).
This results in the availability of more diagnostics during development.
Pass the packet's location and size from outside. This prepares the
logic to cope with situations where the receive buffer contains multiple
(potentially incomplete) packets.
Slightly unobfuscate the UT32x packet parser. The protocol is mostly
ASCII based, checks for hex numbers may be unexpected. Use symbolic
identifiers for the packet length and some special characters.
The previous implementation of the UT32x driver expected to see a conn=
spec, without it no device is found. Default to the USB identification
of the CH9325 chip, to make the driver work out of the box. Users still
can provide conn= specs and override the default for other cables.
Fill in the scan, open/close, get/set/list, acquisition start/stop logic
such that data acquisition with a PICkit2 works.
Trigger support needs more attention. User specified triggers either
seem to not take effect, or the trigger position is not in the expected
location. It's yet to get determined what's the issue.
This implementation is based on protocol information gathered from the
pk2-la project.
Remove a free() call in an error path for a list which immediately
before the call was determined to be NULL. Use index 0 and 1 for
channels P1 and P2 respectively (the previous implementation used 0
for both channels).
The current implementation of the SCPI DMM driver is conservative about
checking the device's being operational, but the *OPC? queries are found
in unfortunate locations. Run the OPC query right before running the
next "actual" command, not afterwards. And certainly not between sending
requests and potentially gathering responses in subsequent calls.
This commit does not change current behaviour, but improves maintenance
before pending commits.
The "get MQ" helper routine communicates SCPI responses and translates
them to internal "MQ and flag" values. Optionally return the MQ table
entry reference to callers, so they don't have to repeat the table
lookup when the function's default precision is required, or should
future "start acquisition" requests need to refer to the meter's current
function.
Supported SCPI DMM devices will differ in the set of options and whether
parameters can get queried or configured. Use a "generic" set of devopts
during scan and for simpler models, prepare support for other sets of
devopts for more complex models.
Implement the scpi-dmm driver in such a generic way that it could work
with several protocol variants and with differing models which happen to
use any of these protocol variants. Prepare a list of supported models
with their respective SCPI command set, set of DMM functions and their
precision.
Add support for Agilent 34405A. The ten functions of this device got
tested and are operational, in continuous mode as well as with sample
count or capture time limits. The driver can query the current meter's
function, can change the function, and can run acquisitions in either
the current mode or with a user specified function selection. There is
some potential for improvement: AUTO/MIN/MAX/HOLD indicators are not
supported by this implementation.
Free the SCPI hardware info after successful model detection, too. Only
allocate the device instance when a supported model was found. Link the
device context earlier right after allocation, for easier verification.
The Fluke 45 probe routine tries to detect whether the serial port is
"in echo mode" (which already is questionable before the IDN query).
In the absence of a response, the library segfaults. Fix it.
Add an "eevblog-121gw" subdriver entry for the EEVblog 121GW multimeter.
Use device dependent channel names instead of the default "P1" etc names.
It's assumed that the device's binary packet data is available at a COM
port. This means that an external BT to UART gateway is required until
BLE communication will be one of libsigrok's native connection types.
Due to some SCPI command changes that Siglent made, the connection
failed due to the wrong commands being send to the device.
This might fix parts of bug #1242, though initial tests show that
further changes might be needed.
[Note: This commit consists of multiple squashed commits from
marchelh <marchelh@gmail.com> and various fixups and rebasing
operations by Uwe Hermann <uwe@hermann-uwe.de>]
The previous implementation always dumped 23 data bytes for received
packets. This could result in truncated diagnostics information, and/or
access to invalid buffer content.
Rephrase the packet dump routine such that the specific meter's exact
packet length gets dumped, and use the common hex dump support code.
Example:
In file included from src/hardware/kecheng-kc-330b/protocol.h:26,
from src/hardware/kecheng-kc-330b/api.c:22:
src/hardware/kecheng-kc-330b/api.c: In function ‘config_list’:
src/libsigrok-internal.h:51:34: warning: division ‘sizeof (void *) / sizeof (void)’ does not compute the number of array elements [-Wsizeof-pointer-div]
#define ARRAY_SIZE(a) (sizeof(a) / sizeof((a)[0]))
^
src/libsigrok-internal.h:55:32: note: in expansion of macro ‘ARRAY_SIZE’
#define ARRAY_AND_SIZE(a) (a), ARRAY_SIZE(a)
^~~~~~~~~~
src/libsigrok-internal.h:964:43: note: in expansion of macro ‘ARRAY_AND_SIZE’
std_opts_config_list(key, data, sdi, cg, ARRAY_AND_SIZE(scanopts), \
^~~~~~~~~~~~~~
src/hardware/kecheng-kc-330b/api.c:296:10: note: in expansion of macro ‘STD_CONFIG_LIST’
return STD_CONFIG_LIST(key, data, sdi, cg, NULL, drvopts, devopts);
^~~~~~~~~~~~~~~
Default to the existing "P1" etc naming scheme for analog channels of
serial-dmm subdrivers. Add support for subdriver specific channel names
(which can reference the channel number if they desire). This is useful
for devices with multiple displays, or special purpose devices where
other names than P1 can better reflect the channel's nature.
Commit 556a926d43 introduced support for multiple displays in
subdrivers of serial-dmm, but also changed user visible channel numbers
to start from 0. Restore the previous behaviour, start counting from 1
which users may perceive as more natural (serial-dmm used to start at P1
in the past, scopes start with CH1 as well).
There are code paths where dev_close() tries to access a USB handle
which does not exist. This was observed with this command:
$ sigrok-cli -d brymen-bm86x --scan
On Windows, this device can either enumerate as 04b4:602a or 04b5:602a,
depending on which vendor driver is currently being used, so we have to
support both in the hantek-6xxx driver as well.
This fixes bug #1295.
The comment says "A requested value is certainly on the way", but the code no
longer works this way. The receive handler requests a value and blocks until
it is received. There is no value pending between receive handler calls, so
this code now only leads to a timeout.
On Windows, this device can either enumerate as 04b4:6022 or 04b5:6022,
depending on which vendor driver is currently being used, so we have to
support both in the hantek-6xxx driver as well.
This fixes bug #918.
This is happening because the send() and recv() functions
have different prototypes on POSIX and Windows. Using the casts
is required on Windows and doesn't hurt on POSIX systems.
[...]/protocol.c: In function 'tcp_send':
[...]/protocol.c:161:26: warning: pointer targets in passing argument 2 of 'send' differ in signedness [-Wpointer-sign]
out = send(tcp->socket, buf, len, 0);
^
In file included from [...]/protocol.c:24:0:
[...]/include/winsock2.h:997:34: note: expected 'const char *' but argument is of type 'const uint8_t * {aka const unsigned char *}'
WINSOCK_API_LINKAGE int WSAAPI send(SOCKET s,const char *buf,int len,int flags);
^
[...]/protocol.c: In function 'ipdbg_la_tcp_receive':
[...]/protocol.c:201:32: warning: pointer targets in passing argument 2 of 'recv' differ in signedness [-Wpointer-sign]
int len = recv(tcp->socket, buf, 1, 0);
^
In file included from [...]/protocol.c:24:0:
[...]/include/winsock2.h:992:34: note: expected 'char *' but argument is of type 'uint8_t * {aka unsigned char *}'
WINSOCK_API_LINKAGE int WSAAPI recv(SOCKET s,char *buf,int len,int flags);
^
[...]/protocol.c: In function 'data_available':
[...]/protocol.c:73:38: error: 'bytes_available' undeclared (first use in this function)
ioctlsocket(tcp->socket, FIONREAD, &bytes_available);
^
[...]/protocol.c:73:38: note: each undeclared identifier is reported only once for each function it appears in
[...]/protocol.c:84:1: warning: no return statement in function returning non-void [-Wreturn-type]
}
^
The fx2lafw(4) driver supports mere logic analyzers as well as mixed
signal devices, but does not support channel group specific device
options. Avoid an error message when channel group device options get
queried, the condition is perfectly legal and non-fatal.
How to reproduce:
$ pulseview -d fx2lafw
$ sigrok-cli -d fx2lafw -g Logic --show
This fixes bug #1267.
The "firmware load failed" message would be even more helpful if users
could learn which firmware file failed to load. Add those filenames to
various FX2-based drivers.
This addresses bug #1262.
As per Daniel Anselmi <danselmi@gmx.ch> in an email conversation, the
code was actually written by Eva Kissling <eva.kissling@bluewin.ch>
(as indicated in the commit logs as well). Fix the headers accordingly.
Use "ipdbg-la" everywhere to refer to the driver, including
in function name prefixes etc. There's no need to encode
website details (.org) into the driver/function name(s).
- add support for multiple transfers.
- set nummber of samples to 1 for FPGA FW version 0
- increase size of data transfer buffer to 2kB.
Signed-off-by: Andrej Valek <andy@skyrain.eu>
Callback for data transfer is separated from status. This change will be
used for better data transfer sending/receiving. Cast signal, that trigger
has been captured was moved into state: H4032L_STATUS_FIRST_TRANSFER.
Signed-off-by: Andrej Valek <andy@skyrain.eu>
- get FPGA version in dev_open
- enable some features only for newer FPGA
- decrease printing number of message of FPGA version
Signed-off-by: Andrej Valek <andy@skyrain.eu>