Previously the USB communication code was split between api.ci,
dslogic.c and protocol.c, with protocol internals split between
both. This patch puts all the protocol handling code into one
source file reducing the number of internal interfaces and making
the code more readable.
Previously the USB communication code was split between api.c
and protocol.c, with protocol internals split between both. This
patch puts all the protocol handling code into one source file
reducing the number of internal interfaces and making the code
more readable.
Handle the case when the sample data memory was filled and has wrapped
around during acquisition. Download the respective part of the data
which is reliably available, only skipping a single 1KB row which might
contain either old or new data while it's not certain which it would be.
This will be essential when triggers later become available. Right now
it copes with user requests for sample counts that exceed the total DRAM
capacity. Instead the maximum available amount of data is provided.
Of course acquisition no longer gets stopped when the end of DRAM is
reached.
Correctly determine the size of a download chunk for the last DRAM row
that's involved in the recent data acquisition.
This commit is based on work done by jry@.
This addresses bug #838 (trailing garbage).
It's assumed that the previously downloaded excess data was "swallowed"
by the sample count enforcement logic that was applied earlier, so the
(remainder of the) issue could have gone unnoticed, unless some other
termination condition than sample count was used.
Configure the samplerate clock and channel count during acquisition
start in identical ways for 50MHz, 100MHz, and 200MHz modes.
This part was inspired by work done by jry@ yet was addressed in
different ways (no exception, do everything in every mode the same way).
Eliminate a portability issue in the previous implementation. Make sure
to send the configuration bytes in the correct order to the hardware.
Don't typecase a struct reference to a bytepointer and hope that the
internal memory representation might fit the external hardware's idea.
Add a comment about sample memory organization in a central spot. This
concentrates knowledge which otherwise would be spread across several
locations all over the driver's codebase, yet is essential to have at
hand during maintenance.
All of the information was determined/updated by jry@ with the help of
Ondrej at Asix when he did lots of fixes and improvements to asix-sigma.
The Asix Sigma hardware does not support a sample count limit. Instead
this optional input parameter gets mapped to a sample time, and some
slack for hardware pipelines and compression gets added. When data
acquisition completes and sample data gets downloaded, chances are that
there is more data than requested by the user.
Do enforce the optional sample count limit. Stop sending data to the
sigrok session when the configured number of samples was sent.
This commit is based on work done by jry@.
This fixes bug #838.
Enhance how the data acquisition is stopped. Wait for the hardware to
flag the successful completion of data retrieval as well as flushing
through hardware pipelines.
Use symbolic identifiers for the mode register's fields (for read as
well as write access).
This commit uses part of a code update to better match the documentation
done by jry@, but not all of it to reduce the size of the commit.
Minor adjustment for improved readability. Don't hide assignments in
variable declarations. Move initialization of some variables closer to
related evaluation or subsequent processing. Break a complicated looking
roundup expression into several short steps.
Fix how the READ_ID register index was passed to the hardware access.
Addresses are sent in nibbles, so shift by eight is wrong here. No harm
was done, as the register's index is zero.
The Asix Sigma driver is aware of three firmware images, which are
required for acquisition with up to 50MHz, 100MHz, and 200MHz. The
previous implementation always downloaded the corresponding firmware
image whenever the sample rate has changed, which was redundant.
Skip the download when the new samplerate uses the same firmware as the
previously selected samplerate did. This results in faster responses in
the GUI when the samplerate selection changes.
Move assignments out of the variable declaration block for improved
readability while we are here.
The hardware provides captured data at a maximum rate of 16bits per 20ns
(50 MHz). For samplerates of 100 and 200 MHz one individual 16bit entity
contains multiple samples for a reduced number of channels. The bits of
several sample points are interleaved within the 16bit entity.
This commit is based on work done by jry@ who fixed a lot of issues with
the help from Ondrej at Asix.
This fixes bug #840.
Adjust the interpretation of acquired sample data such that regardless
of 50/100/200MHz samplerate the assignment of LA pins to sigrok channels
remains stable.
Introduce helper routines to access the sample data that is provided by
the ASIX hardware, as well as the buffer which accumulates logic data
before it gets sent to the session's datafeed.
This hides endianess issues from call sites, and prepares access to
memory layout which varies with sample frequencies.
This commit is based on work done by jry@.
This works around bug #359. Triggers currently are not operational for
Asix Sigma. Don't claim support in the driver so that UIs won't use the
feature. Yet allow research in this issue, by concentrating the switch
for the feature's support in a central location.
Add/update a comment and unobfuscate an error code path while we are here.
Both the .c and the .h file declared the same identifiers for USB
properties of ASIX hardware with identical values. Remove the .c
incarnation and keep the .h content, as the names are used in api.c
as well as protocol.c sources.
Introduce a separate routine which maps sample counts and sample period
to an elapsed sample time after which acquisition shall get stopped.
Add some more time to make sure the most recent captured data has passed
the hardware pipeline and is available for download.
This commit is based on work done by jry@.
When "tsdiff < EVENTS_PER_CLUSTER" we don't want "tsdiff - EVENTS_PER_CLUSTER"
(a negative number) to be treated as (int).
Submitted-By: jry <jrysig@gmail.com>
[ gsi: massaged for mainline submission ]
Bump the number of supported logic channels from 8 to 128. This is
mostly motivated to test the 64 channels limit which some of the
components/subprojects of the sigrok project might have (input/output
modules, user interfaces).
Only automatically enable the first 8 of the 128 total logic channels,
i.e. default to the previous behaviour. Prepare to only enable part of
the set of analog channels, but stick with their being active by default
as well.
Factor out the choice for the default logic pattern, too. This allows
for easier adjustment of the default configuration, when settings are
concentrated in a single spot.
Extend the demo driver, add another waveform choice for logic channels.
Create a "cable squid" logo representation which occupies a large number
of channels.
This pattern occupies 128x128 pixels. Unlike the 'sigrok' pattern it
gets repeated when more channels are involved, but is not shifted in the
repetition.
The handling of the digital channels for this series is somewhere
between that of the DS1000D series (PROTOCOL_V2) and the MSO1000Z
(PROTOCOL_V4).
The :LA command set is similar to that of V4, but the LA data has to be
requested with :WAV:SOUR:LA and arrives in interleaved form like V2.
None of these changes should affect other models. They only affect the
case of PROTOCOL_V3 with digital channels, which occurs only for the
MSO2000A series.
Fixes#933.
We'd already had this problem elsewhere and thus have this wrapper function
that does this where necessary. It just wasn't in use on these two call sites,
which was causing timing problems when used over tcp-raw or VXI transports.
With trigger enabled, and with PulseView, a second (or more) acquisition
starts immediately instead of blocking. It's mandatory to try several times
to have a correct behavior.
According to http://mygizmos.org/ols/Logic-Sniffer-FPGA-Spec.pdf section 2.3.1
p.8, the Openbench Logic Sniffer must be reset before each arm command.
This fixes bug #809.
Signed-off-by: Gwenhael Goavec-Merou <gwenhael.goavec-merou@trabucayre.com>
Openbench Logic Sniffer reset is a little more complex than a simple send.
To avoid code duplication, this patch adds a new function dedicated to
this task.
Signed-off-by: Gwenhael Goavec-Merou <gwenhael.goavec-merou@trabucayre.com>
This changes the fx2lafw code to only enable the wide_sampling (16bit)
method, if at least one of the higher eight channels is enabled. This
has the benefit, that we can use higher samplerates on 16bit LA
devices if we use only the first eight channels.
The wide sampling is also enabled if we have one or more analog
channels.
Signed-off-by: Jan Losinski <losinski@wh2.tu-dresden.de>
devc->step is not reset on acquistion start, so acquisition
starts with a different value every time. Thats annoying when
using the demo driver to debug sigrok, so lets make sure that
it's reset to 0.
Signed-off-by: Sven Schnelle <svens@stackframe.org>
sr_period_string takes the frequency as its argument, i.e. the reciprocal
of the timebase. Obviously this will not work for frequencies less than
1Hz / timebases greater than 1 second, but at least is correct for all
other available timebases.
sr_period_string takes the frequency as its argument, i.e. the reciprocal
of the timebase. Obviously this will not work for frequencies less than
1Hz / timebases greater than 1 second, but at least is correct for all
other available timebases.
Phrase the logic which checks the use of analog channels and digital
pods in more generic terms. Place a comment about the contraints' being
potentially dependent on the specific HMO model. This implementation
should lend itself better to future adjustment (HMO1002?).
An internal libsigrok implementation detail prevents partial submission
of logic data for different channel groups in multiple calls. Instead
one logic packet needs to be sent in a single call, which combines data
for all channels.
Introduce a logic data storage which folds samples from several channel
groups that were received at different points in time into a combined
memory layout of larger unitsize. Stick with the former shortcut of
passing on the input bytes directly when only the first digital pod is
used during acquisition.
This change correctly maps data from the second pod to channels D8-D15.
The previous implementation only added one of the digital channels to
the list of enabled channels that are involved in the acquisition (the
first one that was found). This means that when the set of used digital
channels spans more than one pod/group, the second pod will never be
read from.
Make sure to enable one digital channel per pod/group, such that
acquisition will retrieve data from all involved input sources.
Add comments while we are here. Mention how the different setup, check,
start, and receive routines which are spread across several files do
interact to achieve acquisition.
The previous implementation used to put FRAME_BEGIN and FRAME_END
markers around each received chunk of samples, while those chunks
correspond to a single channel (analog) or a group of eight channels
(digital) each. In other words, the hameg-hmo driver had provided a
multiple of the requested frames, and those frames were incomplete.
Make sure to only send FRAME_BEGIN before the first channel's data,
and FRAME_END after the last channel's data of a frame. Thus make
sigrok frames exactly match the scope's frames.
Add some comments on the frame marker and the acquisition stop logic
while we are here.
Configure the scope to the host's native endianess before downloading
acquisition data from analog channels. This unbreaks operation on those
models which default to a representation which differs from the host.
When the channel state is retrieved, query the pre-set byteorder for
SCPI data blocks as well. When samples get retrieved during capture,
support float representations in either big or little endian format.
This commit unbreaks devices which operate in BE format by default
(tested with HMO2524). It keeps working with LE format as before. For
devices which don't support the byteorder query or return unknown
responses, LE format is assumed for backwards compatibility. The
device's byteorder is only queried and never set. This makes the
commit least intrusive.
A comment mentioned that the models HMO2524 and above support 16 digital
channels (and thus have two pods for the probes). Move those models to a
section that declares the respective features, including trigger support
on the upper digital channels.
Model detection and reflection of supported channels was tested on HMO2524.
Commit db81fbb582 made sure to release a potentially previously
allocated list of enabled channels before (re-)building the list in the
current invocation of acquisition start.
This commit frees the memory in the error path near the failed creation
already, which reduces the period of time where unused resources are
held, and eliminates a memory leak when acquisition is not stopped after
failed start.
Both approaches can coexist. Freeing an empty list is perfectly fine.
Fix the code which registers the name of the second pod for digital
probes. The previous implementation registered the first pod twice, and
lost the reference to the second pod. No harm was done, none of the
supported models declared support for two pods so far.
Factor out a channel to group mapping in the registration of digital
channels, while we are here.
The former DER EE DE-5000 driver was a very thin wrapper around the
ES51919 LCR meter chipset. None of its source was specific to the
deree-de5000 device. In fact it contained code for all currently
supported LCR meters, and it's expected that all LCR meters which
will get added in the future will fit in as well.
Follow the serial-dmm model. Rename the src/hardware/deree-de5000/
directory to serial-lcr/. Update the configure logic. Although the
source directory and the configure option are named serial-lcr, the
LCR meter still is used by specifying the "deree-de5000" device driver
(which just happens to reside in the serial-lcr driver sources, among
others).
The "deree-de5000" driver is a very thin wrapper around the ES51919
chipset. We expect more models from other vendors to use that same
support code.
Model the registration of vendor/model combinations after the serial-dmm
approach. Register the DER EE DE-5000 device as the currently only
member in a list of drivers which all use the ES51919 chipset (no model
specific routines are registered in the absence of support for other LCR
meter chips).
This commit does not change the driver's behaviour nor the set of
supported hardware. It prepares the addition of more drivers in the
future.
Factor out identical comments on the UART bitrate of ES519xx based
multimeters. These probably got copied from the first item as of 2012
when new items were added in 2014 (the added devices were from the
same vendor and rebadged).
Expand on the fact that the bitrate still is within spec, and does not
harm at all. Strictly speaking the comment could get dropped.
The previous implementation seems to have added drivers in their "order
of appearance". Start sorting the rather long list, to simplify several
tasks: Add new entries as more drivers get written, find existing items
during research, identify and compare similar models during maintenance.
As a byproduct, there will be no doubt about where to put things during
future work :) and duplicates will be spotted immediately.
This commit puts 'bm25x' meters into one group. And comments on the sort
order and motivation for sorting the table.
Add another DMM entry for Peaktech-3330, which is based on the FS9721
chipset. Support was tested with the CP210x based USB cable.
Signed-off-by: Gerhard Sittig <gerhard.sittig@gmx.net>
We now require the use of the latest fx2lafw firmware which uses the
same USB VID/PID (1D50:608E) for the Hantek 6022BE and the variants
and rebadges of that device (e.g. the SainSmart DDS120).
The variants can be distinguished via the USB product version field.
This allows much faster and configurable sampling rate, and faster
reaction to function switch.
This also gives a more repeatable job ordering and more reliable
query/reply association.
Fix the array size check in the sigma_write_register() routine. The
'len' parameter specifies the number of bytes to write, while the 'buf'
array holds one nibble per array item.
The previous implementation (commit e8686e3ae3) switched to a
constant size and made the buffer large enough so that no existing
request would exceed the buffer, fixing an overflow that was present
before that commit. But the most recent size check was incomplete and
might erroneously succeed for larger amounts of write data.
It's assumed that the issue which gets addressed here never occured in
practice. The constant-size buffer could hold up to 39 bytes of input
data in their transport representation, while the largest data that was
passed to the write routine is six bytes (trigger LUT params).
Fixes: e8686e3ae3 "asix-sigma: Avoid use of variable length arrays"
Signed-off-by: Gerhard Sittig <gerhard.sittig@gmx.net>
The driver internally implements the "limit samples" feature by means of
the "limit sample period" approach. Determination of the corresponding
period of time for captures depends on the sample rate as well as the
maximum sample count, and thus needs to be re-done when either setting
changes.
Introduce a "limit_samples" variable so that the value is available when
needed later. As a byproduct the parameter can be retrieved now (get).
Add comments to the sigma_set_samplerate() routine's sections, since
quite a bit is happening there, and interacts with other locations.
Signed-off-by: Gerhard Sittig <gerhard.sittig@gmx.net>
Commit 2c9c0df86e removed the sentinel from the samplerates[] array,
but did not adjust the test which checked whether a rate is listed in
the set of supported rates. This could result in an out-of-range access
beyond the array's last item.
Fix the "listed?" check after iterating the table of supported rates.
Cope with either presence or absence of a sentinel in the array.
Address some more style nits while we are here. Rename an identifier
for a local variable which unintentionally might suggest that it would
be a preprocessor macro (all-caps). Reduce redundancy in data type
references as well as in the determination of the array size.
Signed-off-by: Gerhard Sittig <gerhard.sittig@gmx.net>
The current implementation of the ASIX Sigma firmware download contains
comments which express uncertainty. Rephrase them, no magic is involved.
Discuss the polarity of the CCLK hardware signal. Which shall eliminate
potential concerns in future reviews or maintenance.
This commit only updates comments, and does not change behaviour.
Signed-off-by: Gerhard Sittig <gerhard.sittig@gmx.net>
The default so far was 0, which meant there would be no significant
digits at all, yielding results that looked strange/wrong to the user.
Long-term all remaining drivers should be fixed to use the actual,
correct digits and spec_digits values according to the device's
capabilities and/or datasheet/manual. Until that is done, a default
of digits=2 is used as a temporary workaround.
This fixes the remaining parts of bug #815.
Here's a patch to "Ignore requests to set coupling for the Hantek 6022BE",
this clears the LIBUSB errors for me.
Also in the patch:
- There is a crash because config_list() can be called with sdi == NULL.
This can be reproduced by doing:
"sigrok-cli.exe --driver hantek-6xxx --show"
- There seems to be a very unsafe loop in config_set() when setting COUPLING;
the coupling vector is assumed to be zero terminated, but is not declared
as such.
Note: The same issue is present also for other hardware, at least for
hantek-dso/api.c. The patch is only for hantek-6xxx though.
There were issues when using non-power-of-two data sizes with e.g.
the Hantek 6022BE device. For example, on Windows the acquisition would
simply hang and never complete:
hantek-6xxx: receive_transfer(): status LIBUSB_TRANSFER_ERROR received 0 bytes
The issue was reported by Erik Montnemery on the mailing list, the
original patch was posted by "mmark" here (thanks!):
http://www.eevblog.com/forum/testgear/sainsmart-dds120-usb-oscilloscope-(buudai-bm102)/msg911729/#msg911729
The issue has been verified by me on Windows and Linux, and also that
this change does indeed fix it (tested Hantek 6022BE and Sainsmart DDS120).
Neither PulseView nor sigrok-cli hang anymore on Windows, and on Linux
the log messages suggest improvements as well:
-hantek-6xxx: data_amount 712
+hantek-6xxx: data_amount: 200 (rounded to power of 2: 512)
-hantek-6xxx: receive_transfer(): calculated samplerate == 2327ks/s
-hantek-6xxx: receive_transfer(): status LIBUSB_TRANSFER_OVERFLOW received 512 bytes.
+hantek-6xxx: receive_transfer(): calculated samplerate == 1969ks/s
+hantek-6xxx: receive_transfer(): status LIBUSB_SUCCESS / LIBUSB_TRANSFER_COMPLETED received 512 bytes.
This fixes bug #821.
This single object also contains the sr_drivers_init function, that will
always be referenced. That ensures that the drivers object files won't
be optimized out during static linking due to the fact that they are
not referenced directly.
This addresses (parts of) bug #802.
When config_list() gets NULL as sdi, it must return driver opts.
Some drivers, including zeroplus, don't check sdi and return both
driver opts and device opts.
Now that std_serial_dev_acquisition_stop() has the same signature as
the sr_dev_driver dev_acquisition_stop() callback it is possible to remove
the wrapper functions and use std_serial_dev_acquisition_stop() directly
has the callback function.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
All callers of std_serial_dev_acquisition_stop() currently pass the same
callback for the dev_close_fn parameter as the dev_close callback of their
sr_dev_driver struct. Remove the dev_close_fn parameter and invoke the
drivers dev_close() callback directly. This simplifies the API and ensures
consistent behaviour between different drivers.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
All callers of std_serial_dev_acquisition_stop() currently pass sdi->conn
for the serial parameter. And the other std_serial helper functions already
require that the conn field of the sr_driver_inst passed to the functions
points to the sr_serial_dev_inst associated with the device.
Modify std_serial_dev_acquisition_stop() to follow the same pattern and
remove the serial parameter. This simplifies the API and ensures consistent
behaviour between different drivers.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Some of the standard helper functions take a log prefix parameter that is
used when printing messages. This log prefix is almost always identical to
the name field in the driver's sr_dev_driver struct. The only exception are
drivers which register multiple sr_dev_driver structs.
Instead of passing the log prefix as a parameter simply use the driver's
name. This simplifies the API, gives consistent behaviour between different
drivers and also makes it easier to identify where the message originates
when a driver registers sr_dev_driver structs.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
All drivers with the exception of pce-322a pass their dev_close callback to
std_serial_dev_acquisition_stop(). The pce-322a passes std_serial_dev_close()
which is also called from its dev_close() callback and replicates the other
functionality of its dev_close() callback directly in
std_serial_dev_acquisition_stop().
Refactor this to pass the dev_close callback function directly to
std_serial_dev_acquisition_stop(). This makes sure that the driver is
consistent with other drivers and also removes duplicated code.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Use the new software limit helper functions rather than open-coding their
functionality.
This also fixes the issue that driver the does not reset all the limit
statistics in acquisition_start().
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Use the new software limit helper functions rather than open-coding their
functionality.
This also fixes the issue that the driver does not reset the limit
statistics in acquisition_start(). It also makes the time limit work, which
previously was only a stub implementation.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Use the new software limit helper functions rather than open-coding their
functionality.
This also fixes the issue that the driver does not reset the limit
statistics in acquisition_start(). It also makes the time limit work, which
previously was only a stub implementation.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The version field in the norma-dmm driver state struct is initialized, but
never read and the same information is also already available in the
sr_dev_inst struct version field. So remove it to simplify the code.
This allows to get rid of the custom dev_close() callback and just use the
standard std_serial_dev_close() instead.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
../src/hardware/appa-55ii/api.c: In function ‘scan’:
../src/hardware/appa-55ii/api.c:47:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
../src/hardware/arachnid-labs-re-load-pro/api.c: In function ‘scan’:
../src/hardware/arachnid-labs-re-load-pro/api.c:62:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
../src/hardware/atten-pps3xxx/api.c: In function ‘scan’:
../src/hardware/atten-pps3xxx/api.c:81:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
../src/hardware/brymen-dmm/api.c: In function ‘scan’:
../src/hardware/brymen-dmm/api.c:89:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
../src/hardware/cem-dt-885x/api.c: In function ‘scan’:
../src/hardware/cem-dt-885x/api.c:74:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
../src/hardware/conrad-digi-35-cpu/api.c: In function ‘scan’:
../src/hardware/conrad-digi-35-cpu/api.c:45:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
../src/hardware/demo/demo.c: In function ‘scan’:
../src/hardware/demo/demo.c:255:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
../src/hardware/fluke-dmm/api.c: In function ‘fluke_scan’:
../src/hardware/fluke-dmm/api.c:64:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
../src/hardware/gmc-mh-1x-2x/api.c: In function ‘scan_1x_2x_rs232’:
../src/hardware/gmc-mh-1x-2x/api.c:147:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
../src/hardware/gmc-mh-1x-2x/api.c: In function ‘scan_2x_bd232’:
../src/hardware/gmc-mh-1x-2x/api.c:234:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
../src/hardware/ikalogic-scanaplus/api.c: In function ‘scan’:
../src/hardware/ikalogic-scanaplus/api.c:69:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
../src/hardware/tondaj-sl-814/api.c: In function ‘scan’:
../src/hardware/tondaj-sl-814/api.c:44:22: warning: variable ‘drvc’ set but not used [-Wunused-but-set-variable]
struct drv_context *drvc;
^
Some driver scan() functions only ever return a single device. For those it
is possible to slightly simplify the handling of the device list by
creating it on demand when the function returns.
Some drivers also have the following expression:
devices = g_slist_append(devices, sdi);
...
if (!devices)
...
This check will never evaluate to false so it is dropped as well.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
A common task during device scan is to add the newly discovered devices to
the instance list of the driver. Currently this is done by each driver on
its own. This patch introduces a new helper function std_scan_complete()
which takes care of this. The function should be called at the end of a
driver's scan() callback before returning the device list.
Doing this with a helper function provides guaranteed consistent behaviour
among drivers and hopefully paves the way to moving more standard
functionality directly into the sigrok core.
Another common task that every driver has to do for each device instance is
to initialize the device's driver field. So this is done in the new helper
function as well.
All drivers that can make use of the new helper are updated.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Some drivers set the device instance list to NULL in their scan() callback.
This means the driver loses all references to any devices contained in that
list and their resources will be leaked. Drivers can't free the devices at
this point either since an application might still use a device on the
list. So the existing devices on the instance list need to remain
unmodified during the scan() callback, even if that means that there will
be duplicates on the instance list. Only an explicit invocation of
sr_dev_clear() by the application is allowed to free the devices on the
instance list and reset the list.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The link-mso19 driver currently iterates the device instance list of the
driver to get the device instance for which the callback is called.
But the device instance is actually passed to the callback as the cb_data
parameter, so just use that instead and remove the lookup loop.
Besides that the current lookup loop does not even compile either.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The link-mso19 open-codes the std_dev_clear() function and uses it as its
custom dev_clear() callback. The std_dev_clear() function is automatically
called if no custom dev_clear() callback is specified, so just drop custom
implementation and use the default.
This also fixes a memory leak where the link-mso19 driver did not properly
free its driver state struct in the dev_clear() callback.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
sdi is allocated using g_malloc0() which can never fail, in addition to
that sdi is already dereferenced before the check, which makes the check
useless. So remove it.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
HP instruments predating the 488.2 and SCPI standards do not
necessarily have a SCPI-compliant command set. The HP6630A series of
supplies is one such example.
While scpi-pps is flexible enough to accomodate almost any command
syntax given the right profile, it still assumes that "*IDN?" is the
correct question to ask the instrument. Since older HP gear instead
responds to "ID?", this assumption is no longer true.
Thus sr_scpi_get_hw_id() is not appropriate for these instruments, and
the shadow driver added here only replaces that function call, while
reusing the rest of the existing logic. The extra noise is necessary
in order to propagate this through the .scan member of the driver.
Use the standard connection_id field from the struct sr_dev_inst for
storing the device address rather than using the custom address field in
the driver state struct. This makes things more consistent with the
framework.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The sigrok core needs a list of all available drivers. Currently this list
is manually maintained by updating a global list whenever a driver is added
or removed.
Introduce a new special section that contains the list of all drivers. The
SR_REGISTER_DEV_DRIVER() and SR_REGISTER_DEV_DRIVER_LIST() macro is used to
add drivers to this new list. This is done by placing the pointers to the
driver into a special section. Since nothing else is in this section it is
known that it is simply a list of driver pointers and the core can iterate
over it as if it was an array.
The advantage of this approach is that the code necessary to add a driver
to the list is completely contained to the driver source and it is no
longer necessary to maintain a global list. If a driver is built it will
automatically appear in the list, if it is not built in won't. This means
that the list is always correct, whereas the previous approach used ifdefs
in the global driver list file which could get out-of-sync with the actual
condition when the driver was built.
Any sr_dev_driver structs that are no longer used outside the driver module
are marked as static.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Most drivers have a forward declaration to their sr_dev_driver struct at
the beginning of the driver file. This is due to historic reasons and often
no longer required. So remove all the unnecessary forward declarations.
Some drivers still require the forward declaration, but only reference the
driver struct from within the driver scan() callback. Since the driver
struct is passed to the scan callback replace the references to the global
variable with the local parameter. In some cases this requires adding the
parameter to some of the helper functions that are called from the scan()
callback.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
To capture more than 16MSamples the hardware run length encoding option
must be enabled, or captured data present errors.
RLE encoding/decoding is done in hardware. Data streamed to the USB interface
is not encoded.
This commit enables RLE encoding for captures longer than 16MSamples.
Signed-off-by: Diego Asanza <f.asanza@gmail.com>
This commit expands support for acquisition using an external clock,
now allowing the user to select the clock edge.
Signed-off-by: Diego Asanza <f.asanza@gmail.com>
For low sampling speeds (up to 25MHz) DSLogic offers a streaming mode where
samples are sent directly to the USB interface, like a fx2lafw device.
For high sampling speeds (up to 400MHz) only buffer mode is supported.
This commit allows the user to set which mode should be used. The configuration
is done by using SR_CONF_CONTINUOUS.
Signed-off-by: Diego Asanza <f.asanza@gmail.com>
The DSLogic provides two FPGA images: one for 3.3V and the other for 5V logic.
The DSLogic Pro allows to set an arbitrary voltage threshold via USB command.
This commit adds support for the DSLogic to load the FPGA image according to
an user-selectable voltage threshold.
For the DSLogic Pro, one of two fixed voltage thresholds are set, depending on
the user-selected value.
Tested with DSLogic and DSLogic Pro.
Signed-off-by: Diego Asanza <f.asanza@gmail.com>
Tested-by: Andrew Bradford <andrew@bradfordembedded.com>
This commit implements DSLogic trigger functionality.
The following triggers are working:
- trigger on rising edge
- trigger on falling edge
- trigger on any edge
- trigger on logic one
- trigger on logic zero
Pre-trigger capture ratio is also working.
Signed-off-by: Diego Asanza <f.asanza@gmail.com>
Tested-by: Andrew Bradford <andrew@bradfordembedded.com>
The demo device has support for specifying the number of analog and logic
channels it should have. Currently this does not work correctly if one of
them is set to zero. Being able to set the number of channels to zero for
one of the channel types is quite useful for corner case testing though.
Make the following modifications to handle it correctly:
1) If the channel count is zero no channel group for that channel type
should be created since a channel group needs at least one channel.
2) Drop the check if logic_unitsize is less or equal to zero in
prepare_data() since this condition will always be true if the number of
logic channels is zero and it is not possible to create a demo device with
only analog channels.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Now that the signature of std_init() matches that of the driver init()
callback we can remove all wrapper functions around std_init() and use it
directly as the init() callback.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
std_init() checks if the pass in struct sr_dev_driver is non-NULL and
prints a error message and returns an error if it is NULL.
std_init() is exclusively called from driver init() callbacks for which the
core already checks if the struct sr_dev_driver is non-NULL before invoking
the callback. This means the check in std_init() will always evaluate to
false. So drop this check.
This also means that the prefix parameter that was used in the error
message is no longer needed and can be removed from the function signature.
Doing so will make the std_init() function signature identical to the
init() callback signature which will allow to directly use it as such.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The std_init() callback has the order of the first two paramters opposite
to the init() callback. This is primarily due to historical development.
Since the std_init() function is usually called from a driver's init()
callback aligning the order will allow direct register pass through rather
than having to swap them around. It also allow to eventually use the
std_init() function directly as the init() callback.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The zeroplus-logic-cube driver uses libusb_get_device_list() but neglects
to call the matching libusb_device_list_free() on the error path. This will
leak the memory allocated for the list as well as all the devices.
To address the issue use sr_usb_open() instead of open-coding its
functionality. sr_usb_open() correctly handles freeing the device list.
The issue was discovered using the following coccinelle semantic patch:
// <smpl>
@@
identifier devlist;
expression ctx, ret;
statement S;
@@
(
libusb_get_device_list(ctx, &devlist);
|
ret = libusb_get_device_list(ctx, &devlist);
if (ret < 0) S
)
... when != libusb_free_device_list(devlist, ...)
*return ...;
// </smpl>
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The victor-dmm driver uses libusb_get_device_list() but neglects to call
the matching libusb_device_list_free() on the error path of libusb_open().
This will leak the memory allocated for the list as well as all the
devices.
To address the issue use sr_usb_open() instead of open-coding its
functionality. sr_usb_open() correctly handles freeing the device list.
The issue was discovered using the following coccinelle semantic patch:
// <smpl>
@@
identifier devlist;
expression ctx, ret;
statement S;
@@
(
libusb_get_device_list(ctx, &devlist);
|
ret = libusb_get_device_list(ctx, &devlist);
if (ret < 0) S
)
... when != libusb_free_device_list(devlist, ...)
*return ...;
// </smpl>
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
The testo driver uses libusb_get_device_list() but neglects to call the
matching libusb_device_list_free() on the error path. This will leak the
memory allocated for the list as well as all the devices.
To address the issue use sr_usb_open() instead of open-coding its
functionality. sr_usb_open() correctly handles freeing the device list.
The issue was discovered using the following coccinelle semantic patch:
// <smpl>
@@
identifier devlist;
expression ctx, ret;
statement S;
@@
(
libusb_get_device_list(ctx, &devlist);
|
ret = libusb_get_device_list(ctx, &devlist);
if (ret < 0) S
)
... when != libusb_free_device_list(devlist, ...)
*return ...;
// </smpl>
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
lascar_scan() calls libusb_get_device_list() but never the matching
libusb_free_device_list(). This will leak the memory allocated for the
device list as well as all the devices. To fix this add the missing
libusb_free_device_list().
While we are at it also make sure to handle errors returned by
libusb_get_device_list().
The issue was discovered using the following coccinelle semantic patch:
// <smpl>
@@
identifier devlist;
expression ctx, ret;
statement S;
@@
(
libusb_get_device_list(ctx, &devlist);
|
ret = libusb_get_device_list(ctx, &devlist);
if (ret < 0) S
)
... when != libusb_free_device_list(devlist, ...)
*return ...;
// </smpl>
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Some drivers check in some of their driver callbacks if the driver has been
initialized and return an error if it has not.
For the scan() callback the sigrok core checks if the driver has been
initialized and if not returns an error. So it is not possible that the
scan() callback gets called if the driver is not initialized. Without the
scan() callback succeeding it is not possible to get a reference to a
device which is associated with the driver, so it is not possible that any
of the device specific callbacks is called without the driver first being
initialized either.
In conclusion these checks are not necessary since they never evaluate to
true and can be dropped. If they should ever become necessary they should
be done in the sigrok core so all drivers and all callbacks are equally
handled.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
SR_CONF_CONTINUOUS is a capability option indicating whether a device
supports continuous capture or not. If the option exists the device
supports continuous capture and otherwise it doesn't. There is no value
associated with it and hence setting the SR_CONF_SET flag is nonsensical.
None of the drivers which set SR_CONF_SET for SR_CONF_CONTINUOUS handle it
in their config_set() callback and return an error if an application tried
to perform a config_set() operation for SR_CONF_CONTINUOUS.
Simply remove the SR_CONF_SET flag from all SR_CONF_CONTINUOUS options.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Every single hardware driver has the very same implementation of the
dev_list() callback. Put this into a helper function in the standard helper
library and use it throughout the drivers. This reduces boiler-plate code
by quite a bit.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
If a driver does not implement a dev_clear() callback the core will
automatically call std_dev_clear(di, NULL). Remove all driver dev_clear()
implementations that are identical to default. This reduces the amount of
boiler-plate code.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
std_init() allocates a drv_context struct which needs to be freed by the
driver in its cleanup struct. But the vast majority of drivers does never
does this causing memory leaks.
Instead of addressing the issue by manually adding code to free the struct
to each driver introduce a new helper function std_cleanup() that takes
care of this. In addition to freeing the drv_context struct std_cleanup()
also invokes sr_dev_clear() which takes care of freeing all devices
attached to the driver.
Combining both operations in the same helper function allows to use
std_cleanup() as the cleanup callback for all existing drivers, which
reduces the amount of boiler-plate code quite a bit.
All drivers are updated to use the new helper function.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Devices for the scpi-pps driver do have additional data attached to it that
needs to be freed when the device is freed. While the driver gets it right
for the cleanup() callback it does not for the dev_clear() callback. This
will cause memory leaks when sr_dev_clear() is called for this driver.
To fix this let the dev_clear() free the additional data.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Devices for the deree-de5000 driver do have additional data attached to it
that needs to be freed when the device is freed. While the driver gets it
right for the cleanup() callback it does not implement a dev_clear()
callback, so the default dev_clear() implementation is used which will not
free the additional data. This will cause memory leaks when sr_dev_clear()
is called for this driver.
To fix this provide a dev_clear() implementation that frees the additional
data.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Devices for the demo driver do have additional data attached to it that
needs to be freed when the device is freed. While the driver gets it right
for the cleanup() callback it does not implement a dev_clear() callback, so
the default dev_clear() implementation is used which will not free the
additional data. This will cause memory leaks when sr_dev_clear() is called
for this driver.
To fix this provide a dev_clear() implementation that frees the additional
data.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
When g_file_get_contents() encounters an error a new GError will be
allocated and passed back to the application. The application is
responsible for freeing this GError.
The baylibre-acme driver currently does not do this and as a result leaks
memory during the scan process when no device is found.
Add the missing g_error_free() invocations to fix the issue.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Make sure to free the FTDI device list and the FTDI context in scan_all()
otherwise memory leaks can be observed. Also make sure to free the FTDI
context in scan_device() on the error path.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
This makes the code shorter, simpler and more consistent, and also
ensures that the (same) debug messages are always emitted and the
packet.payload field is consistently set to NULL always, etc.
The USBee AX hardware needs a sampling clock that is lower than
the 30MHz or 48MHz that the FX2 has to offer. This flag will enable
clocking via the CTL2 pin that is an even divisor of the main clock.
The driver did not look at the mq_flags provided with the
SR_CONF_MEASURED_QUANTITY key, and it defaulted to DC measurements.
Use the second member of the tuple provided by the config key, which
represents the flags for the measurement, and set the instrument's
measurement mode accordingly.
Due to a PEBKAC error, after the last sample was sent, a new
measurement was triggered, but its value was never sent down the
session bus. This is easily fixed by incrementing devc->num_samples
right after a measurement is sent instead of when a measurement is
retriggered.
Using non power of 2 sizes causes the driver to not work on OS X.
Depending on the usb transfer mode the buffer sizes will map
perfectly to the underlying transport protocol.
scpi_serial generate an POLLIN event after the requested data is returned
by the instrument. For USBTMC it is necessary to
1. send an REQUEST_DEV_DEP_MSG_IN request
2. submit an USB bulk read transfer asynchronously.
Using the synchronous libusb_bulk_read() does not generate an POLLIN event.
Solving this properly needs major surgery in spci_usbtmc_libusb.
After acquisition start, DSLogic stores samples in memory, and when done it
sends a USB packet with the trigger position.
This initial fillup can take some time. If the user requests a session stop
in between, the USB transfer is cancelled and the session hangs because it
is not closed properly.
This commit manages this case and closes the session properly when
acquisition is stopped by the user.
Signed-off-by: Diego F. Asanza <f.asanza@gmail.com>
For some reason, uploading the FPGA binary into DSLogic in small chunks
does not work. In this commit, the whole binary image is loaded into memory
and transfer is done in one chunk.
Furthermore, the FPGA configuration structure was not initialized
properly. This was changed with the initialization values taken from the
original DSLogic software.
Signed-off-by: Diego Asanza <f.asanza@gmail.com>
Certain output modules do not understand double-precision data.
Although we need double precision to represent the full resolution
of 7.5 digit readings, temporarily convert data to single precision
so that the output modules understand it. While the reasing might be
off by a few counts, we ensure the output modules do not display
completely bogus data.
For details, see bug #779.
KNOWN ISSUES:
- When sampling with 100 NPLC, the poll function will timeout a few
times before the first sample is acquired. Increasing the timeout
passed to sr_scpi_source_add() will cause all the other commands to
be processed slowly, producing a sampling rate of about one sample
every ten seconds.
- Support for plug-in cards (44491A and 44492A) is not implemented.
- Support for AC, AC+DC and four-wire resistance measurements is not
implemented.
- Support for configuring the frequency measurement source is not
implemented.
Note: This commit is based on the initial implementation by
Christer Ekholm (but stashed into one commit), with some adaptations
(forward porting, coding style and consistency fixes) by Uwe Hermann.
The firmware has "on\n" and "off\n" commands since 1.10, so use them.
Apparently you can only set the state (on/off) of the load, but it's
not possible to query the current state.
Also note that the __ namespace is reserved by POSIX for its private
usage, so user land software should never rely on any kind of API
with a __ prefix.
For session sources without a file descriptor to poll a negative number
should be passed for the fd parameter. The hung-chang-dso-2100 driver
currently passes 0 instead, which is the stdin stream. Fix the issue by
passing -1 for the fd parameter.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
src/hardware/lecroy-logicstudio/protocol.c: In function 'handle_fetch_samples_done':
src/hardware/lecroy-logicstudio/protocol.c:261:3: warning: passing argument 6 of 'libusb_fill_bulk_transfer' from incompatible pointer type
recv_bulk_transfer, (void *)sdi, USB_TIMEOUT_MS);
^
In file included from ./src/libsigrok-internal.h:31:0,
from src/hardware/lecroy-logicstudio/protocol.h:26,
from src/hardware/lecroy-logicstudio/protocol.c:23:
/home/uwe/sr_mingw/include/libusb-1.0/libusb.h:1546:20: note: expected 'libusb_transfer_cb_fn' but argument is of type 'void (*)(struct libusb_transfer *)'
static inline void libusb_fill_bulk_transfer(struct libusb_transfer *transfer,
^
src/hardware/lecroy-logicstudio/protocol.c: In function 'fetch_samples_async':
src/hardware/lecroy-logicstudio/protocol.c:314:4: warning: passing argument 6 of 'write_registers_async' from incompatible pointer type
handle_fetch_samples_done);
^
src/hardware/lecroy-logicstudio/protocol.c:200:12: note: expected 'libusb_transfer_cb_fn' but argument is of type 'void (*)(struct libusb_transfer *)'
static int write_registers_async(const struct sr_dev_inst *sdi,
^
src/hardware/lecroy-logicstudio/protocol.c: In function 'lls_start_acquisition':
src/hardware/lecroy-logicstudio/protocol.c:1122:3: warning: passing argument 6 of 'libusb_fill_interrupt_transfer' from incompatible pointer type
recv_intr_transfer, (void *) sdi, USB_TIMEOUT_MS);
^
In file included from ./src/libsigrok-internal.h:31:0,
from src/hardware/lecroy-logicstudio/protocol.h:26,
from src/hardware/lecroy-logicstudio/protocol.c:23:
/home/uwe/sr_mingw/include/libusb-1.0/libusb.h:1602:20: note: expected 'libusb_transfer_cb_fn' but argument is of type 'void (*)(struct libusb_transfer *)'
static inline void libusb_fill_interrupt_transfer(
^
This g_close(), the only one in the whole code-base, would unnecessarily
raise the minimum glib version to 2.36.
Thanks to Daniel Glöckner for the report.
This fixes bug #724.
In some situations, the reply to the *IDN? command contains an
additional trailing 0x01 byte for unknown reasons.
This issue seems to be reproducible by changing the voltage using the knobs
on the device, then turning on the output and turning it off again.
The next korad-kaxxxxp scan() operation would contain the trailing 0x01
byte, which would lead to the detection of the device in libsigrok no
longer working until the next power-cycle.
Work around this issue by treating both the ID string with and without
the trailing 0x01 byte as valid.
This is a desperate measure to improve the success rate of device
initialization even after it got into a bad state. Combine this
with a reduced USB timeout (1 second) so that if it fails, it fails
quickly. Also ignore USB errors from the initial dummy read of the
device test ID.
Detect whether the FX2 firmware of the LWLA device exhibits the
short transfer bug. If so, work around the problem by limiting
reads to at most 64 bytes at a time. This slows down the memory
read after acquisition quite noticably, but makes the device
usable even in adverse conditions.
Reduce the number of long registers read in bulk during status
polling from 10 to 5. The LWLA1034 driver used to do that already
in an earlier iteration, which was then changed to be more like
the original vendor software. The reason for bringing it back now
is that it reduces the response size to 40 bytes, which works
around the spurious 64 byte limit bug in the FX2 firmware of the
LWLA devices.
The sixth character from ISET? is read and discarded. If the device is
turned off and on again, this won't be there and causes 10 ms delay in
every ISET? Luckily, this value isn't queried that often. To get the
sixth byte, the *IDN? command has to be issued before ISET?.
Do not use size_t for values whose width is defined by the device,
not the host. Also don't use size_t for simple indices with known
small range, unless type compatibility considerations apply.
Refactor the sysclk-lwla driver to separate the generic logic from
the model-specific implementation. Based on this, implement support
for the SysClk LWLA1016 device.
The driver should now be able to cope with e.g. multiple ChronoVu LA8
and/or ChronoVu LA16 devices being connected to the same PC.
It now also provides the serial number and connection ID, which can be
used by frontends to differentiate multiple devices.
Also improve the scanopts / drvopts / devopts lists handling.
This fixes bug #504.
With the current driver API and the corresponding session event
handling, it is not possible to destroy and then re-create an
event source with the same key within the same main loop iteration.
The next generation driver API will fix this problem. But for now,
just change the driver to make do without that sort of thing. Also
increase the I/O timeout to 100 ms to be safer in the event of all
kind of delays the OS environment may induce.
This fixes bug #678.
Evaluate all 64 bit of the duration field in the capture status
record. Although unlikely in practical use, due to compression
it is possible for the duration in ms to exceed 32 bit.
During initialization of the LWLA1034, read the 64-bit test word
twice and verify the result of the second read only. This better
matches what the original vendor software does.
Apparently, these four registers form an interface for indirect
access to another internal 64 bit wide memory. This is likely the
same memory as that accessed by the bulk transfer commands 7 and 8.
Added support for SR_CONF_REGULATION which returns value for CH1
Also VELLEMAN LABPS3005D (only device currently supported) sends single
'M' character in beginning of return value, which is specially discarded.
Trying to configure an invalid capture ratio would reset the
previously configured value. Instead, we should just reject the
new value and keep the original one.
With this driver it is possible to set voltage target and current
limit. Also enabling and disabling the output is possible.
Analog output sends read back values from output. If output is
disabled analog outputs 0.00.
In protocol.c there is a g_usleep() call. This gives almost
every time enough time for PSU to parse and process input.
Multichannel devices aren't supported.
Instead of using a non-standard packed attribute, read the contents of the
probe EEPROM into a buffer and then process it using the R* macros.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Standard integer types may differ in size on different targets. Use fixed-size
types instead.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
This fixes parts of bug #423.
The list of fixed warnings:
src/output/srzip.c:285:3: warning: Value stored to 'ret' is never read
ret = zip_append(o, logic->data, logic->unitsize, logic->length);
^ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
src/scpi/scpi.c:610:2: warning: Value stored to 'ret' is never read
ret = SR_OK;
^ ~~~~~
src/scpi/scpi.c:667:2: warning: Value stored to 'ret' is never read
ret = SR_OK;
^ ~~~~~
src/dmm/vc870.c:410:2: warning: Value stored to 'info_local' is never read
info_local = (struct vc870_info *)info;
^ ~~~~~~~~~~~~~~~~~~~~~~~~~
src/hardware/conrad-digi-35-cpu/api.c:130:2: warning: Value stored to 'ret' is never read
ret = SR_OK;
^ ~~~~~
src/hardware/fx2lafw/api.c:658:2: warning: Value stored to 'timeout' is never read
timeout = fx2lafw_get_timeout(devc);
^ ~~~~~~~~~~~~~~~~~~~~~~~~~
src/hardware/gmc-mh-1x-2x/protocol.c:941:3: warning: Value stored to 'retc' is never read
retc = SR_ERR_ARG;
^ ~~~~~~~~~~
src/hardware/gmc-mh-1x-2x/api.c:168:2: warning: Value stored to 'model' is never read
model = METRAHIT_NONE;
^ ~~~~~~~~~~~~~
src/hardware/ikalogic-scanalogic2/api.c:325:2: warning: Value stored to 'ret' is never read
ret = SR_OK;
^ ~~~~~
src/hardware/openbench-logic-sniffer/api.c:185:3: warning: Value stored to 'devc' is never read
devc = sdi->priv;
^ ~~~~~~~~~
src/hardware/rigol-ds/api.c:813:3: warning: Value stored to 'devc' is never read
devc = sdi->priv;
^ ~~~~~~~~~
src/hardware/scpi-pps/api.c:405:2: warning: Value stored to 'ret' is never read
ret = SR_OK;
^ ~~~~~
src/hardware/yokogawa-dlm/api.c:239:2: warning: Value stored to 'ret' is never read
ret = SR_ERR_NA;
^ ~~~~~~~~~
Timer intervals shorter than about 100 ms are unnecessarily taxing
on system resources. Also, on systems like Windows the smallest
resolvable time unit without using high precision timers is about
15 ms. Regular timer intervals should be well above that value to
avoid being dominated by noise and round-off.
Firmware versions starting with 00.02.04 apparently cause the in and out
bulk endpoints to end up in a HALT state. This is likely related to the
larger transfer size quirk implemented in the Linux kernel for the Rigol
DS1000: this USBTMC implementation does not have that workaround.
Instead, if the firmware version is >= 00.02.04, both endpoints have the HALT
condition cleared on device close.
This fixes bug #354.
GPIO direction should be set once right after exporting. There's no need
to reset it again - in fact it's a bug which causes the probe to be reset
every time the value is read/set and gives incorrect results when reading
the GPIO values with direction == 'in'.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Revision B of ACME hardware introduces probes with on-board at24cs02
EEPROM. Extend the ACME driver to support reading the contents of
the EEPROM via linux' sysfs interface.
Also: make the driver be able to tell the difference between revisions,
add new GPIO layout and set the shunt resistance for revB at probe
registration.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Only perform a single check at initialization time to see if the probe is
equipped with a power-switch. This is done in preparation for revision B
support which has this kind of information encoded in EEPROM.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
After opening the USB device, set the device configuration to 1.
Actually, do it twice, just as the vendor driver seems to do. This
is supposed to trigger a lightweight reset of the device.
Originally, I omitted this reset sequence from the sigrok driver
because it simply did not work at all for me. However, it does seem
to work now, so that may have been a problem in libusb or the kernel
which is now fixed.
With some luck, this change may finally fix#327.
Use states SR_ST_ACTIVE and SR_ST_INACTIVE to indicate that the
device is open or closed, respectively. Do not use any of the
other state values. Improve the robustness of the open and close
methods in face of errors. Introduce a separate flag to indicate
that a running acquisition should be canceled.
Prepare the trigger masks at config_commit() time, so that the
trigger setup can be validated before starting an acquisition.
Accordingly, do actually report validation errors back to the
caller.
It turns out that g_stat() breaks apart when using 64 bit stat on
32-bit systems. Since the actual type of GStatBuf is decided when
glib/gstdio.h is included, it is thus possible for GLib itself to
be compiled with a different type than user code.
Ouch. Unfortunately going back to plain stat() also means that we
lose Unicode filename support on Windows.
Since Autoconf places some important feature flags only into the
configuration header, it is necessary to include it globally to
guarantee a consistent build.
A few of these were pretty serious, like missing arguments,
passing integers where a string was expected, and so on.
In some places, change the types used by the code rather than
just the format strings.
The Hung-Chang DSO-2100 is a parallel port PC oscilloscope sold back
in 1999 under brand names like Protek and Voltcraft.
This inital version of the driver has the following limitations:
- Hardcoded calibration values. All parameters are set to 50%.
- No support for auto triggering
- No support for TV sync trigger modes
- No support for the "scroll acquisition" mode
In scroll acquisition mode the device behaves more like a multimeter
and reports the current voltage of a probe on request. While in this
mode the sample rate is limited by the parallel port interface, it is
the only way to capture both channels at the same time (well, sort of).
Calibration would need auto triggering. The calibration values are very
temperature dependent and the device takes literally hours to reach its
final temperature. Every vdiv setting needs its own set of calibration
values. Without hardware modifications, the calibration settings wear
of in less than a second while waiting for a trigger because the
capacitors storing those values are not recharged in state 0x21.
In sr_session_iteration(), remove the inverted evaluation of the
block parameter if a USB source is present. This stops the deluge
of USB event callbacks due to the timeout always being zero.
Also, just for cleanliness, initialize the revents member of each
GPollFD instance to zero.
Move the include flags for files in the source tree from
configure.ac to Makefile.am where they belong. Also use
AM_CPPFLAGS instead of CFLAGS/CXXFLAGS to make sure the
files in the build/source tree are always picked up first.
Also, remove the include/libsigrok sub-directory from the
search path, thereby making the <libsigrok/> prefix mandatory
when building libsigrok itself. This matches the convention
already imposed on users of the library.
- Don't #include <errno.h> in files that don't actually need it.
- Don't use strerror() on error codes from functions that don't set
errno. Replace strerror() with sr_strerror() for libsigrok functions.
Fixes a bug where new acquisition failes due to leftover pipes from
previous acquisitions:
sr: demo: dev_acquisition_start: pipe() failed
Indeed, PulseView had 2024 pipes opened. With this fix, it stabilizes at
33 with sampling thread active.
Signed-off-by: Hubert CHAUMETTE <hchaumette@baylibre.com>
Move the libusb_detach_kernel_driver() call after the code that
sets the usb->devhdl pointer, otherwise it'll be NULL and result
in a segfault.
#0 libusb_kernel_driver_active (dev=0x0, interface_number=0) at libusb/core.c:1711
#1 dev_open (sdi=0x12d99f0) at src/hardware/fx2lafw/api.c:374
[...]
Tested on a device with the default Cypress VID/PID and one with
the Saleae Logic VID/PID, both works fine.
The timerfd descriptor is closed automatically by
g_io_channel_shutdown(). No need to close it manually.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
At high sampling rates and maximum channels we are not able to acquire
samples fast enough, even though frontends still think that samples
arrive on time. This causes visible shifts in frontend plots.
To compensate for the delay introduce the following workaround: check
if we are late (if any clock events have been missed) and resend the
last frame n times (n == number of missed clock events).
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Currently baylibre-acme uses a fake pipe as the input channel required by
libsigrok API and calls sleep() in the data acquisition callback to create
intervals between measurements.
Switch to a more elegant approach: use Linux' timerfd and set a periodic
timer equal to the sampling rate. Then read the data every time the timer
expires.
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Opening a file has a cost (security, allocation, syscalls). The
read_sample() function always does an open/read/close sequence.
In order to optimize that, let's open the file at the moment the
acquisition starts, close it when the acquisition stops and make
read_sample() only lseek() to the beginning of the file and read
the value.
Signed-off-by: Daniel Lezcano <daniel.lezcano@free.fr>
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
This was originally done as an optimization in combination with a list
reversal which has since been removed from the code. Thus, un-reverse
the channels so that the UI lists them in the correct order again.
The Chroma 62000P series comes in various models with different
current and voltage capabilities. These are encoded in the *IDN
string, so just get them from there, rather than needing a profile
for every model.
All those options are currently applied only to power-supplies
but they could apply as well to electronic loads, except for the
fact that electronic loads channels are called inputs and not
outputs.
Also when you think about an SMU (or any kind of 4-quadrants
power-supply), their channels can both source and sink current,
so they can be considered as input as much as output.
Those SR_CONF_* are thus renamed so that they can be used in all
those situations.
For devices such as the HP 6632B the following invocation was failing due to
scpi_cmd(sdi, SCPI_CMD_SELECT_CHANNEL, ...) returning SR_OK_CONTINUE.
./sigrok-cli -d scpi-pps:conn=/dev/ttyUSB0:serialcomm=9600/8n1 --continuous
sr: session: sr_session_start: could not start an acquisition (not enough data to decide error status yet)
Failed to start session.
This patch only adds the needed infrastructure to control output
frequency in the same manner as output voltage or current limit. This
does require a new field in the channel_spec struct, for the sake of
symmetry.
Only the capabilities which map directly to SCPI commands supported by
sigrok are implemented at this time. This is sufficient to control
the most often used functionality of this AC source
Check the return value of sr_gpio_setval_export() in bl_acme_set_power_off()
and return an appropriate error if the call fails.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
This reverts commit 4cd97e5ad7.
We should actually check the return value of sr_gpio_setval_export().
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Add LIBUSB_CALL where needed to avoid warnings such as the following:
In file included from src/hardware/hantek-dso/api.c:34:0:
src/hardware/hantek-dso/dso.h:212:13:
note: expected 'libusb_transfer_cb_fn' but argument is of type 'void (*)(struct libusb_transfer *)'
SR_PRIV int dso_get_channeldata(const struct sr_dev_inst *sdi,
^
CC src/hardware/baylibre-acme/protocol.lo
../src/hardware/baylibre-acme/protocol.c: In function 'bl_acme_set_power_off':
../src/hardware/baylibre-acme/protocol.c:417:6: warning: variable 'val' set but not used [-Wunused-but-set-variable]
int val;
^
Both ina2xx and tmp401 linux drivers used by baylibre-acme expose
the standard hwmon update_interval attribute, which affects the internal
update interval of the chip.
When setting samplerate for data acquisition try to modify this
attribute accordingly.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
PROBE_FACTOR and POWER_OFF options are advertised for all ACME probes
(channel groups) regardless of whether they actually have given capability.
Check these options in config_list() at runtime and only advertise them
for probes which support them.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Tested on an MSO1104Z with firmware 00.04.02.SP4.
The analog channels are captured correctly. For the MSO series, with digital
channels, there are two outstanding issues:
1. Logic data is retrieved per-channel, one byte per sample, with the value
in the LSB of each byte. The current datafeed logic format doesn't allow
this format to be passed on directly. I suggest we resolve that rather than
making the driver buffer and interleave the data.
As stands, the code will retrieve data for all channels and pass it onto
the datafeed with unitsize=1. Channel D0 can used correctly if selected
alone. For other channels, data is passed to the frontend but the API does
not provide a way to associate it with the correct channel.
2. Channels CH3 and CH4 are multiplexed with D0-7 and D8-15 respectively, so
enabling these is mutually exclusive. We don't currently have a way to
express this constraint to the frontend.
This patchset was originally done by eightdot <gituser@eightdot.eu> by
manually forward-porting parts of the changes done by Bert Vermeulen (see
previous commits), but then heavily modified by Uwe Hermann to be based on
top off the (git-)rebased patches from Bert Vermeulen instead.
Note: This initial DSLogic code is *not* yet in a working or usable
state. It should be considered as a basis for further work only, for now.
CC src/hardware/openbench-logic-sniffer/api.lo
../src/hardware/openbench-logic-sniffer/api.c: In function 'scan':
../src/hardware/openbench-logic-sniffer/api.c:103:10: warning: unused
variable 'probefd' [-Wunused-variable]
GPollFD probefd;
^
Use the more portable sp_input_waiting() instead of g_poll() with FDs.
Thanks to Martin Ling for the hints. This is tested on Linux and Win7
using an OLS; scanning for the device and starting an acquisition works.
Also, add some more debug output.
This fixes bug #562.
Split device options into general and channel group settings, and
adjust config_list() callback appropriately.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
There's indeed no g_fclose() unfortunately. The g_*() wrappers for file
handling are mainly there to deal with portability issues in file names
(encoding, character sets, etc) on different platforms.
Use PRIu64 to avoid the following compiler warning:
CC src/hardware/baylibre-acme/gpio.lo
protocol.c: In function 'bl_acme_set_shunt':
protocol.c:341:2: warning: format '%llu' expects argument of type 'long long unsigned int', but argument 3 has type 'uint64_t' [-Wformat=]
g_fprintf(fd, "%llu\n", MOHM_TO_UOHM(shunt));
^
Implement support for SR_CONF_PROBE_FACTOR setting in BayLibre ACME
driver. Given the channel-group parameter this allows to set the
shunt resistance for each probe.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Implement basic functionalities for baylibre-acme. Add support
for common config options, device detection and sample reading.
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
We try to find the smallest diff by comparing each diff with
the previously known smallest diff, so initially, this smallest diff
should be INFINITY so that we are sure to find a smaller one.
This fixes the following exception:
sr: rigol-ds: Negative vdiv index: -1.
Caught exception: not applicable
These are available on e.g. Rigol DS1102E (or "upgraded" DS1052E).
Without this, if one of the channels happens to have been set to
one of the missing vdiv settings frontends (e.g. PulseView) will
have some trouble using the scope:
sr: hwdriver: sr_config_get(): key 30012 (vdiv) sdi 0x11bcb70 cg CH1
sr: rigol-ds: Negative vdiv index: -1.
std::exception
(lwla_convert_trigger): Fix trigger mask computation bug introduced
by recent change: Widen constant to 64 bit before shifting so that
channel nunmbers beyond 32 are processed correctly.
Use g_malloc0() for small allocations and assume they always
succeed. Simplify error handling in a few places accordingly.
Don't always sanity-check parameters for non-public (SR_PRIV)
functions, we require the developers to invoke them correctly.
This allows further error handling simplifications.
It fills the fields with reasonable default values that should suit
most of the drivers. Drivers are obviously free to override the fields
they want after initializing.
If the number and specs of the device's channels are not static, i.e.
need to be probed, this facility is needed.
Initially this will be used for the Philips PM2800 series, where only
the model returned by *IDN? is needed. However this could also be used
to do actual discovery with vendor-specific SCPI commands.
At least the Rigol DP800 series trigger the beeper when changing
channels remotely. Which gets rather annoying when doing acquisition
on three channels as fast as you can.
Add a driver for the DER EE DE-5000 LCR meter. This meter is based on
the Cyrustek ES51919/ES51920 chipset and communicates with the host
computer via an optional connectivity kit.
The kit uses an optoisolated unidirectional link to connect to the
meter and an USB cable on the host side. Internally the connection is
using the FTDI FT232R USB UART chip i.e. from the host computer point
of view the meter is connected into an RS-232 serial port.
This driver implements just a thin shim layer for registering the
driver and uses the es51919 module for all the actual work.
Set this new parameter to 0 (no timeout) at every call site. This is
consistent with previous behaviour, so cannot cause any regressions.
Waiting forever for a serial operation is clearly always wrong. Without
specific knowledge of each device and driver however, I can't choose
appropriate timeouts for each call. The maintainers of these drivers
will need to do so, and also add appropriate handling of timeouts.
When this commit is merged, a bug should be entered for each driver
that is touched by it.
Previously, sdi->index was used to tell several identical fx2lafw-compatible
devices apart. This was a bit of a hack, so this patch makes it use physical
device connections instead. They're guaranteed to remain the same even if
the USB device reconnects.
These calls are executed from an event handler and were previously nonblocking,
but they have no partial read/write handling. The code is already marked TODO
for improvement.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. It only reads one byte, and a zero result is handled
appropriately.
This call was previously explicitly nonblocking, but has no partial write
handling. It sends a short packet so should be OK to block, most likely the
output buffer will be empty anyway.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. It only reads one byte, and a zero result is handled
appropriately.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
These calls are executed from an event handler and were previously nonblocking,
but have no partial write handling. They send short packets so should be OK to
block, most likely the output buffer will be empty anyway.
Fix error handling for some: serial_write can return any negative error code.
This call was previously nonblocking, but there is no handling of partial
writes. It is called from config_set where it is free to block.
Also fix error handling: serial_write can return any negative error code,
not just -1.
These calls were already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. They only read one byte. A return value of zero is not
handled, but should not occur in theory due to the G_IO_IN check. It might be
good to add handling of a zero return anyway, since I'm not sure if this is
always accurate.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. It only reads one byte, and a zero result is handled
appropriately.
These calls are executed from an event handler and were previously nonblocking,
but have no partial write handling. They send short packets so should be OK to
block, most likely the output buffer will be empty anyway.
Also fix error handling for these calls, which seems to have been retained from
previous direct usage of write() to a serial port fd.
These calls were previously nonblocking, but have no partial write handling.
They are made from scan and acquisition_start contexts where they are free
to block.
Remove the SERIAL_NONBLOCK at open, which only applied during scan, since all
calls in the scan are now explicitly blocking.
Also fix error handling for these calls, which appears to have been kept
from a previous direct usage of write() on a serial port fd.
This call was already nonblocking since the driver opens the port with the
SERIAL_NONBLOCK flag. Only one byte is read. The case of 0 being returned
is not handled, but the call is only made if G_IO_IN occurred so in theory,
there should be a byte available. It might be wise to add handling for a
return of 0 nonetheless, as I'm not sure if this is always accurate.
This is an odd one. These calls are made from a receive handler so should not
block, and appear to be setup correctly to handle partial reads or no data
available. However, the driver was not opening the port with SERIAL_NONBLOCK
so these calls would have been blocking. Make them nonblocking.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
These calls were already nonblocking since this driver opened the port with
the SERIAL_NONBLOCK flag. Having marked them as such, we can remove the flag.
Also remove an unnecessary reopen of the port to change its blocking status.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
This call is executed from an event handler and was previously nonblocking,
but has no partial write handling. It sends a short packet so should be OK
to block, most likely the output buffer will be empty anyway.
This is called at scan time so free to block. There is no partial write
handling and a response is expected afterwards. This should therefore be a
blocking call.
This call is executed from an event handler context was previously
nonblocking, however there is no handling for a partial write.
The output buffer is unlikely to be full and the commands to be sent
are short, so it should be OK to make this a blocking call.
This call is executed at scan time so is free to block. There is no
handling for a partial write and a response is expected immediately
afterwards. It should therefore be a blocking call.
Every driver now publishes its device option config keys, i.e. the
list fetched with sr_config_list(SR_CONF_DEVICE_OPTIONS), with a
set of flags indicating which methods are implemented by the driver
for that key.
The config keys are OR'ed with any combination of SR_CONF_GET,
SR_CONF_SET and SR_CONF_LIST. These are defined as the high bits
of the uint32_t config key. Clients can OR config keys with
SR_CONF_MASK to strip out these bits. This mask will be kept up to
date if other bits are added to the capabilities list; clients MUST
therefore use SR_CONF_MASK for this.
Some keys don't have capability bits added, such as the informative
device type keys (SR_CONF_MULTIMETER, SR_CONF_OSCILLOSCOPE, ...) and
SR_CONF_CONTINUOUS.
Scan options do not have capabilities bits.